Chimney and Connector
Connect to a listed chimney or a chimney suitable for use with solid fuel that is lined and in good condition and meets
local building codes. The chimney flue size should be the same as the stove outlet for optimal performance. Reducing
or increasing the flue size may adversely affect stove performance. The installation must meet all local codes. Do not
connect this unit to a chimney flue serving another appliance. Minimum system height is 15 feet (4.6 m.) (measured from
base of appliance). Chimney flue exit is to be 3 feet (1 m.) above roof and two feet (0.6 m.) above highest projection
within 10 feet (3 m.).
Double-Wall Connector
•
Use a listed double-wall connector.
•
Install all components to the chimney connector manufacturer's installation requirements.
Single-Wall Connector
Smoke pipe must be:
• As short and straight as possible, use six inch diameter, 24 gauge black pipe that is clean and in new condition.
• Secured at every joint and collar with 3 sheet metal screws.
• Installed with the crimped or male ends pointing down. This will carry any liquid creosote or condensation back into
the stove.
• The chimney connector shall not pass through an attic, roof space, closet or similar concealed space, floor, or
ceiling. Where passage through a wall, or partition of combustible material is desired, the installation shall conform
to CAN/CSA-B365, Installation Code for Solid-Fuel-Burning Appliances and Equipment or in the U.S., NFPA 211:
Standard for Chimneys, Fireplaces, Vents, and Solid Fuel-Burning Appliances.
6"
150mm
7"
180mm
7"
180mm
20-1/4"
515mm
7"
180mm
6"
150mm
20-1/4"
515mm
Rear Venting Minimum Clearances to Combustibles
Figure 15: Alt 1.2 Clearances Rear Vent.