Warning:
Under no circumstances is this heater to be installed in a makeshift or "temporary" manner. It may
be fired only after the following conditions have been met.
• DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
• DO NOT INSTALL IN A SLEEPING ROOM.
• CAUTION: THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR, WALL AND CEILING/
ROOF MUST BE MAINTAINED.
• The stove must be achored to the floor. Use the holes located in the back of the legs.
• Outside air supply must be used for Mobile Home installations - see Figure 6 on page 16.
• The services of a competent or certified installer, (certified by the Wood Energy Technical Training program
(WETT) - in Canada, Hearth Education Foundation (HEARTH) - in U.S.A.,) are strongly recommended.
Clearances
This heater must be installed with listed double-wall connector and compatible ULC-S629 or UL-103HT listed
chimney system.
Clearances to combustible surfaces and materials are shown in Figure 12.
Consult local fire codes and authorities for approval.
NOTE: Install all chimney components to the connector and chimney manufacturer's installation
requirements. Consult your chimney supplier/manufacturer for installation advice.
Mobile Home Installation
18"
457mm
18
5/8
"
473mm
22
1/8
"
562mm
32
5/8
"
829mm
10"
254mm
8"
203mm
8"
203mm
Mobile Home - Double Wall Connector only
Figure 12: T6 Minimum clearances - Mobile Home.
ALDERLEA T6-LE_260319-28
21
100000087