QC SERIES MANUAL
file:///C|/PACH-CO.COM-2022-B/online_manual/qc_series_manual.htm[4/27/2022 8:58:09 AM]
1.
AC1 and AC2
, Input Power 12VAC 40VA (supplied) or 12VDC 3.0A (not supplied). Measurement voltage under
load must be 12.50-14.00 VAC (AC Transformer) or 13.50-14.00 VDC (DC power supply)
2.
BAT and GND
, Battery backup 12VDC 4.5Ahr.
3.
DOOR 2
, Dry contact relay for door strike or gate operator (must use separate power supply for the door strike)
4.
DOOR 1
, Dry contatctrelay for door strike or gate operator (must use separate power supply for the door strike)
5.
NTEL1 and NTEL
2, Telephone Out loop to next system (if more than one system and sharing the phone line)
6.
CO1 and CO2
, Analog Dial Tone telephone input.
7.
AUX1, AUX2 and GND
, Connect input device such exit switch, postal lock, etc.
8.
DOORS1, DOORS2, GND
, Door Sensor, connect to door swicth to monitor door opening and closing.
9.
RS-485
, Slave units connection, up to 8 slave units.
10.
26-BIT Wiegand Input
QWCM IS OPTIONAL FOR QC1 AND QC1FF
11.
12VDC and GND,
Factory use only to power the QWCM
12.
QWCM
, Power and Communication connector,
Do Not remove the connector with the power On.
13.
QWCM ETHERNET PORT
, Connect to the Router or Switch
14.
RS232
, Communication port,
Do Not remove the connector with the power On
15.
MASTER CODE RETRIEVAL BUTTO
N, Press and release then press 00# to retrieve the current Master Code.
16.
VOLUME ADJUSMENT
, Counter clockwise to increase volume, Clockwise to decrease volume.
Assuming all wiring has been done properly according to
then turn the system On using the power switch as
shown above on diagram. The LCD will display as below