3.

Press the Scroll Up (

) Key.  The Set Temperature is now displayed, immediately perform

step 4.  If a Password has been previously programmed into the system, "EP0" will be appear
on the LED Display at this point. When this message appears, the operator must enter the
correct Password before adjusting the temperature.

4.

Adjust the temperature by pressing and holding Scroll Up (

) Key or Scroll Down (

) key.

Observe the display as the Set Temperature increases first in increments of 1° and then in
increments of 10°.  When the desired temperature is reached, release the key.  

NOTE:  

The

Set Temperature can only be within the set temperature limits.  If the lower limit is reached,
the display will read off.  If the upper limit has been reached, the display will read “HiL”.
Temperature limits can be adjusted in the Set-Up Mode

5.

Press the Program Key (

) and the system will return to normal operation.

6.

Observe the Digital Readout as the temperature reaches and stabilizes at the Set Tip
Temperature

7.

Manually force the system into Temperature Setback by pressing and holding the Scroll
Down (

) Key and the Scroll Up (

) Key.

8.

When the display begins to blink, the system is in Temperature Setback mode and will
reduce the set temperature to 177°C (350°F).  

NOTE:  

If Auto Off has been enabled in the

Set-Up Mode, the system will enter Auto Off (temperature Off and LED Display flashing "Off")
after the preset time of handpiece inactivity.  Auto Off can be exited by pressing any key.

9.

To exit Temperature Setback mode, perform any one of the following:

a) Press and release a Key (any of the 3 keys).  This is the preferred method.
b) Wipe the hot handpiece tip on a wet sponge to lower the tip temperature.
c)

Turn the Power Switch Off ("0") and then back on ("I").

10.  The system is now in normal operation.  Observe the LED Display as the tip temperature

reaches and stabilizes at the Set Temperature.  Allow time for the temperature to stabilize at
the Set Temperature before using.

NOTE:  

Read the “Customize Your System” sections of this manual to utilize the full capabilities of

the system.

LED Display, Normal Operation

The LED Display provides a 3-digit display of temperature information.  The LED Display will show:

1.  A display of "888" on initial power up to ensure that all LEDs on the display are

working.

2.

A display of the software version of the installed microprocessor (e.g., "1-2") for 2
seconds on initial power up after the "888" is displayed.

3.

Actual tip temperature of the connected handpiece during normal operation.

The tip temperature displayed will flash when the system is in Temperature
Setback.

5.

The displayed temperature will decrease and stabilize at 177°C (350°F) when the system is
in Temperature Setback.

6.

"OFF" when the Set Tip Temperature has been set to Off (below minimum set tip
temperature).  Refer to the "Set-Up Mode" portion of this manual.

7.

"OFF" plus the LED Display will be flashing when the unit has entered Auto Off.
Refer to the "Set-Up Mode" portion of this manual.

Error messages ("OSE", "SSE" or "OCE") if a system fault is detected.  Refer to the
"Corrective Maintenance" portion of this manual.

LED Display, Temperature Adjust Mode

The LED Display will show the following when adjusting the desired Set Tip Temperature.

1.

The Set Tip Temperature.

Содержание ST 45

Страница 1: ...WORLDWIDE Operation and Maintenance Manual for the ST 45 ST 55 Soldering Systems P N 5050 0453 Rev D...

Страница 2: ...Power Up 9 Heater Burn In 9 Tip Installation 10 Definitions 10 Quick Start Procedure 11 Operation 11 LED Display Normal Operation 12 LED Display Temperature Adjust Mode 12 Temperature Setback 13 Auto...

Страница 3: ...pecifications System Power Source Power Requirements ST 45 or ST 55 Operates on 97 127 VAC 50 60Hz 90 Watts maximum at 115 VAC 60Hz ST 45E or ST 55E Operates on 197 253 VAC 50 60Hz 80 Watts maximum at...

Страница 4: ...mmended by the manufacturer Directives de S curit Fran aise Langue Les pr cautions suivantes sont celles que le personnel doit comprendre et suivre lorsqu il utilise effectue la maintenance ou se sert...

Страница 5: ...alle die in den Sicherheitsdatenblaettern des Herstellers ausgewiesenen Sicherheitsvorschriften eingehalten werden Misure di Sicurezza Italiana Lingua Le seguenti instruzioni sono misure di sicurezza...

Страница 6: ...siga sempre todas as precau es de seguran a recomendadas pelo fabricante Guias de Consulta de Seguridad Esp nol Lenguaje Lo siguiente es precauciones de seguridad que el personal debe entender y debe...

Страница 7: ...saTemp verktygselement och installerade spetsar r heta n r str mmen r p slagen och en tid efter att str mmen slagits av R R EJ element eller spets Risk f r br nnskador 4 PACE Spets och Verktygsh llare...

Страница 8: ...and tighten by hand 6 Angle the power source so the operator can see the display easily and tighten the nuts with a wrench or pliers Tip Tool Stand The Tip Tool Stand can be mounted to the power sourc...

Страница 9: ...tabilize at 315 C 600 F for 10 minutes 7 At the conclusion of the 10 minute period the heater temperature will increase to 427 C 800 F for 15 minutes 8 At the conclusion of the 15 minute time period t...

Страница 10: ...Set Tip Temperature may be adjusted Temperature Display Impedance TDI Mode Stabilizes the tip temperature shown on the LED Display by ignoring minor temperature fluctuations Displayed changes in tempe...

Страница 11: ...for use in standard soldering operations Simply perform the following Quick Start Procedure to begin using the system The systems can be stacked on each other for convenience and to preserve bench top...

Страница 12: ...back mode perform any one of the following a Press and release a Key any of the 3 keys This is the preferred method b Wipe the hot handpiece tip on a wet sponge to lower the tip temperature c Turn the...

Страница 13: ...lly activate after a preselected period 10 90 minutes of handpiece inactivity See the Customizing your System section for details on programming this feature 2 MANUAL ACTIVATION The operator can manua...

Страница 14: ...then returns to normal operation If this occurs repeat steps 1 through 5 and enter the correct Password 5 The LED Display reads P Choose one of the following options a Press the Program Key to keep th...

Страница 15: ...e Program Key to proceed to the next step NOTE If the attached handpiece is disconnected when the system is powered up any stored Offset Constant is reset to zero The Offset Constant must be entered a...

Страница 16: ...the features and factory settings of each To change and or learn about any of these features refer to the applicable part of the Customizing Your System section of this manual Feature Factory Setting...

Страница 17: ...to the applicable manuals for troubleshooting procedures pertinent to these handpieces Perform the procedures with the handpiece heater at room temperature If the heater is warm resistance readings wi...

Страница 18: ...he replacement Heater Assembly with the keyway slot on the handle 5 Push the Heater Assembly fully into the handle 6 Replace the Heater Retaining Nut and tighten by hand Packing List Quantity Supplied...

Страница 19: ...ters are normally warranted for a period of six 6 months from the date of receipt by the original purchaser PACE MAKES NO OTHER WARRANTY EXPRESSED OR IMPLIED AND MAKES NO WARRANTY OF MERCHANTABILITY O...

Страница 20: ...products or services Arm Evac Flo D Sodr Mini Wave PACE SensaTemp Snap Vac SODRTEK SM Sodr X Tractor THERMO DRIVE ThermoFlo ThermoJet ThermoTweeze TOOLNET VisiFilter PERMAGROUND TM Tip Brite TM Auto...

Отзывы: