background image

©2001 PACE Inc., Laurel, Maryland

Page 4 of 14

All Rights Reserved

English Language Safety Guidelines

The following are safety precautions that personnel must understand and follow when using or servicing
this product.

1.

POTENTIAL SHOCK HAZARD - 

Repair procedures on PACE products should be performed

by Qualified Service Personnel only.  Line voltage parts may be exposed when the
equipment is disassembled.  Service personnel must avoid contact with these parts when
troubleshooting the product.

2. To prevent personnel injury, adhere to safety guidelines in accordance with OSHA and other

applicable safety standards.

3. SensaTemp handpiece heaters and installed tips are hot when the handpiece is powered on

and for a period of time after power off.  

DO NOT

 touch either the heater or the tip.  Severe

burns may result.

4. PACE Tip & Tool Stands and handpiece cubbies are designed specifically for use with the

associated handpiece and houses it in a manner that protects the user from accidental burns.
Always store the handpiece in its holder.  Be sure to place the handpiece in its holder after
use and allow for cooling before storing.

5. Always use PACE systems in a well ventilated area.  A fume extraction system such as those

available from PACE are highly recommended to help protect personnel from solder flux
fumes.

6.  Exercise proper precautions when using chemicals (e.g., solder paste).  Refer to the Material

Safety Data Sheet (MSDS) supplied with each chemical and adhere to all safety precautions
recommended by the manufacturer.

Directives de Sécurité, Française Langue

Les précautions suivantes, sont celles que le personnel doit comprendre et suivre lorsqu'il utilise, effectue
la maintenance ou se sert d'un produit PACE.

1.

Danger potentiel de choc èlectrique - 

Les procédures de réparation sur les produits PACE

doivent être effectuées seulement par du personnel qualifié.  Des parties de l'équipement
désassemblées peuvent être sous tension.  Le personnel de maintenance doit éviter tout
contact avec ces parties en réparant le produit.

2. Pour prévenir tout préjudice, le personnel adhère au guide de sécurité en accord avec OSHA

(équivalent à des normes françaises de sécurité) et d'autres standards de sécurité applicable.

3. La mise sous tension des outils SensaTemp comporte des éléments chauffants (buse).  Ces

derniers, gardent la chaleur même après la mise hors tension pendant un certain temps.  

Ne

pas

 toucher les parties chaudes aux extrémités des outils.  Des brûlures sévères peuvent en

résulter.

4. Les outils PACE et leurs pannes ainsi que le support sont dessinés de manière spécifique

afin de protéger l'utilisateur/opérateur de brûlures accidentelles.  Reposer toujours les outils
après chaque utilisation dans leurs étuis/supports afin de permettre leur refroidissement.

5. Utiliser toujours les stations Pace dans unlieu bien ventilé.  Des extracteurs de fumée Pace

sont hautement recommandés pour protéger votre personnel des vapeurs de soudure/flux.

6. Prenez les mesures nécessaires quand vous utilisez des produits (ex: solder paste) chimiques.

Reportez-vous au document (fiche technique/sécurité) du fabricant fourni avec chaque produit.
Respectez toutes les procédures de sécurité recommandées par le constructeur.

Содержание ST 25

Страница 1: ...WORLDWIDE Operation and Maintenance Manual for the ST 25 ST 35 Soldering Systems P N 5050 0452 Rev D ...

Страница 2: ...Guidelines Portuguese Language 6 Safety Guidelines Spanish Language 6 Safety Guidelines Swedish Language 7 System Set Up Mounting Options 8 Tip Tool Stand 8 Handpiece Connection 8 System Power Up 9 Heater Burn In 9 Tip Installation 9 Operation Variable Temperature Control 10 Temperature Dial Lock 10 LED Operation 10 Temperature Dial Adjustment 10 Corrective Maintenance Power Source 11 Handpieces 1...

Страница 3: ...nment Specifications System Power Source Power Requirements ST 25 or ST 35 Operates on 97 127 VAC 50 60Hz 90 Watts maximum at 115 VAC 60Hz ST 25E or ST 35E Operates on 197 253 VAC 50 60Hz 80 Watts maximum at 230 VAC 50Hz Temperature Specifications Handpieces Tip Temperature Range 204 to 455 C 400 to 850 F nominal Temperature Stability 1 1 C 2 F at idle from set tip temp NOTE Actual minimum and max...

Страница 4: ...by the manufacturer Directives de Sécurité Française Langue Les précautions suivantes sont celles que le personnel doit comprendre et suivre lorsqu il utilise effectue la maintenance ou se sert d un produit PACE 1 Danger potentiel de choc èlectrique Les procédures de réparation sur les produits PACE doivent être effectuées seulement par du personnel qualifié Des parties de l équipement désassemblé...

Страница 5: ...e die in den Sicherheitsdatenblaettern des Herstellers ausgewiesenen Sicherheitsvorschriften eingehalten werden Misure di Sicurezza Italiana Lingua Le seguenti instruzioni sono misure di sicurezza che il personale deve comprendere e seguire quando utilizza o ripara I prodotti PACE 1 EVENTUALI RISCHI DI SHOCK ELETTRICO Si consiglia di far eseguire le operazioni di riparazione dei prodotti PACE da u...

Страница 6: ... e siga sempre todas as precauções de segurança recomendadas pelo fabricante Guias de Consulta de Seguridad Espãnol Lenguaje Lo siguiente es precauciones de seguridad que el personal debe entender y debe seguir al usar o reparar productos de PACE 1 RIESGO de SHOCK POTENCIAL Los procedimientos de la Reparación en productos de PACE sólo deben ser realizados por Personal de Servicio Calificado Pueden...

Страница 7: ...saTemp verktygselement och installerade spetsar är heta när strömmen är påslagen och en tid efter att strömmen slagits av RÖR EJ element eller spets Risk för brännskador 4 PACE Spets och Verktygshållare är speciellt utformade för att passa PACE respektive verktyg så att risken för brännskador kan undvikas När verktyget ej används bör det alltid förvaras i sin hållare 5 Tillse att ventilationen är ...

Страница 8: ... can see the display easily 7 Tighten the nuts with a wrench or pliers Tip Tool Stand The Tip Tool Stand can be mounted to the power source If the system will be placed on the workbench this is recommended If the ST 35 is to be mounted under the workbench or shelf the Tip Tool Stand should not be mounted to the power source 1 To attach the stand to the power source a Insert the 2 Mounting Screws h...

Страница 9: ...nclusion of the Burn In procedure This procedure should be performed whenever a new handpiece or new heater is connected to the system PS 70 PS 90 Tip Installation For maximum productivity and proper fit install tips into your soldering iron when the heater is hot CAUTION To avoid burns or potential injury always hold the handpiece with the heater pointed at an angle up to prevent injury Installin...

Страница 10: ...ain set temperature LED Off No power is being delivered to the handpiece heater This condition is evident for a short period of time when set temperature is reached and stabilizing or if the Variable Temperature Control setting is decreased If the LED never illuminates check for a faulty handpiece see Corrective Maintenance section Also if no handpiece is connected to the power source the LED will...

Страница 11: ...n Contact PACE Table 1 Power Source Corrective Maintenance Handpieces The following Heater Assembly Checkout Procedures Table 2 is applicable to all PACE SensaTemp handpieces used with the ST 25 or ST 35 system except for the TT 65 and DTP 80 handpieces Refer to the applicable manuals for troubleshooting procedures pertinent to these handpieces Perform the procedures with the handpiece heater at r...

Страница 12: ...r key on the handle end of the replacement Heater Assembly with the keyway slot on the handle 5 Push the Heater Assembly fully into the handle 6 Replace the Heater Retaining Nut and tighten by hand Packing List Quantity Supplied ST 25 or ST 35 with PS 70 ST 25 or ST 35 with PS 90 ST 25 TT Item Description Part Number ST 25 ST 35 ST 25E ST 35E ST 25 ST 35 ST 25E ST 35E ST 25 ST 25E 1 System Power S...

Страница 13: ... the date of receipt by the original purchaser PACE MAKES NO OTHER WARRANTY EXPRESSED OR IMPLIED AND MAKES NO WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE PACE will at its option repair or replace any defective equipment or parts at its facility or other location approved by PACE at no charge to the user or provide parts without charge for installation by the user in the field a...

Страница 14: ...E products or services Arm Evac Flo D Sodr Mini Wave PACE SensaTemp Snap Vac SODRTEK SM Sodr X Tractor THERMO DRIVE ThermoFlo ThermoJet ThermoTweeze TOOLNET VisiFilter PERMAGROUND TM Tip Brite TM Auto Off TM Additional copies of this manual or other PACE literature may be obtained from www paceworldwide com PACE USA PACE Europe 9893 Brewers Court Sherbourne House Laurel MD 20723 Sherbourne Drive U...

Отзывы: