background image

 

 

 

Operation and Maintenance Manual for  

MTS Rework Systems

 

 P/N 5050-0520, Rev B  

 
 

 

Voltage 

Part Number 

MTS 200 SC System 

115 VAC 

8007-0414 

MTS 200 SC System 

230 VAC 

8007-0415 

MTS 200 SA System 

115 VAC 

8007-0412 

MTS 200 SA System 

230 VAC 

8007-0413 

MTS 300 System 

115 VAC 

8007-0418-B 

MTS 300 System 

230 VAC 

8007-0419-B 

MTS 350 System 

115 VAC 

8007-0416-B 

MTS 350 System 

230 VAC 

8007-0417-B 

 

 

 

(MTS 200 Shown with optional TD-100 and SX-80 Handpieces) 

 

Содержание MTS 200

Страница 1: ...VAC 8007 0414 MTS 200 SC System 230 VAC 8007 0415 MTS 200 SA System 115 VAC 8007 0412 MTS 200 SA System 230 VAC 8007 0413 MTS 300 System 115 VAC 8007 0418 B MTS 300 System 230 VAC 8007 0419 B MTS 350...

Страница 2: ...n 4 Safety 5 System Set Up 5 Mounting Options 5 System Power Up 5 Handpieces 6 Handpiece Tip Tool Stands 6 Adjusting the Angle of the Cubby 6 Handpiece Connection 6 Operation of MTS Systems 6 Vacuum P...

Страница 3: ...e FH channel the MTS 350 features 1 HC channel and 2 FH channels The system also comes standard with Auto Setback and Auto Off functions to preserve tip life Applicable Regulations MTS systems are ava...

Страница 4: ...1 3 Amp 115 VAC 60 Hz Max OR 7 Amp 230 VAC 50 Hz Max Fuse 2 Amp SloBlo 115 V System 1 Amp TimeBlo 230 V System MTS 350 1 3 Amp 115 VAC 60 Hz Max OR 7 Amp 230 VAC 50 Hz Max Fuse 2 Amp SloBlo 115 V Syst...

Страница 5: ...CE systems in a well ventilated area A fume extraction system such as those available from PACE are highly recommended to help protect personnel from solder flux fumes 6 Exercise proper precautions wh...

Страница 6: ...ector and handpiece port on the system For example HC handpieces have the red connector and will only connect to red ports Likewise Fixed Heater handpieces have black connectors and can only be connec...

Страница 7: ...Features These are pre programmed for 30 minute Auto Setback and 30 minute Auto Off which can be turned off by the switch on the back of the unit If the handpiece channel has not been used for 30 min...

Страница 8: ...iFilter FLOW OUT side into the power source Vacuum Port 3 When using air pressure and or utilizing multiple air handpieces PACE recommends the use of the following set up procedure which utilizes addi...

Страница 9: ...one of the same rated value Handpiece will not heat Defective Heater Change Tip Cartridge Power Source Malfunction Contact PACE Power Source Corrective Maintenance Packing Contents Description MTS 200...

Страница 10: ...WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE Seller will at its option repair or replace any defective products at its facility or other location approved by it at no charge to user...

Страница 11: ...BRITE AUTO OFF and TEKLINK The following are registered trademarks and or service marks of PACE Incorporated Annapolis Junction Maryland U S A ARM EVAC FLO D SODR MINIWAVE PACE SENSATEMP SNAP VAC SOD...

Отзывы: