background image

2

PACE Incorporated retains the right to make changes to specifications contained
herein at any time, without notice.

Contact your local authorized PACE Distributor or PACE Incorporated to obtain the
latest specifications.

The following are registered trademarks and/or servicemarks of PACE Incorporated,
Laurel Maryland U.S.A. and may only be used to identify genuine PACE products or
services:

Cir-Kit, ComForm I, ConducTweez, CRAFT, Dual Path, Flo-D-Sodr, FuseSet,
HotSpot, LapFlo, MBT, MicroChine, Micro Portable, MiniChine, Pacenter,
PACE, Ped-A-Vac, PETS, PRC, PRINT, ResisTweez, SensaTemp, SMR,
Sodr-X-Tractor, StripTweez, SwaPlater, ThermoBand, ThermoPart,
ThermoPik, ThermoJet, ThermoTweez, Thermo-Drive, VisiFilter.

The following are trademarks and/or servicemarks of PACE Incorporated, Laurel
Maryland U.S.A. and may only be used to identify genuine PACE products or
services:

AdapTip, Arm-Evac, DEXITEST, EKO, HandiPik,PIK-VAC, Pro-Evac,
Redi-Rak, SNAP-VAC, SR-3, SR-4, ST, Tip-Evac.

PACE Incorporated has provided training on all of its products since 1958 as well as

from:

PACE Incorporated

(301) 490 - 9860

Sales Administration

(301) 4983252 Fax

9893 Brewers Court
Laurel MD 20723-1990

©1992 PACE Incorporated, Laurel MD.  All rights reserved.  Printed in the U.S.A.

advanced technology training in all aspects of hand soldering, rework and
repair.

Additional copies of this manual or other PACE literature may be obtained

Содержание MBT250

Страница 1: ...r local authorized PACE dealer or contact PACE directly at Telephone 301 490 9860 Fax 301 604 9215 PACEIncorporated 9893 Brewers Court Laurel MD 20723 1990 MBT 250 220 CALIBRATION KIT PACE P N 6993 01...

Страница 2: ...ractor StripTweez SwaPlater ThermoBand ThermoPart ThermoPik ThermoJet ThermoTweez Thermo Drive VisiFilter The following are trademarks and or servicemarks of PACE Incorporated Laurel Maryland U S A an...

Страница 3: ...PTION 1 An optional KeyLock feature is available from PACE which prevents unauthorized alteration of stored data or calibration of the system Check the rear panel of the system power source If the Key...

Страница 4: ...the system LEDs will light TheTemperatureDisplaywillread 888 and change to read 1 X 5 Release the Tip Temperature Set and Scroll Down Keys The Temperature Display will now read CAL and only the three...

Страница 5: ...meaning that Automatic Setback is turned off A readout of 1 thru 9 on the right side of the Digital Readout indicates time toAutomatic Setback in increments of 10 minutes For example S 3 would indicat...

Страница 6: ...matic Setback feature is enabled No additional steps are necessary CHANNEL SELECTION 11 The Channel 1 LED is now lit signifying that Channel 1 is ready for calibration Perform steps 12 through 21 to c...

Страница 7: ...ys as necessary to increase Scroll Up Key or decrease Scroll Down Key the Lower TemperatureLimitvalue 14 Press and release the Tip Temperature Set Key to store the display value into memory UPPER TEMP...

Страница 8: ...he displayed value into memory TheDigitalReadoutwillnow display C 1 NOTE Ifyoudonotwishtorecalibrateforreadout accuracy press theTIPTEMPERATURE OFFSETKeyandperformsteps12through 17 Afterallchannelshav...

Страница 9: ...processor controlled circuitry is recalibrating one aspect of the system circuity C 2 will now be displayed 20 Unplug the 1 Calibration Assembly and plug in the 2 CalibrationAssembly READOUT ACCURACY...

Страница 10: ...to exit calibration All values features and defaults entered during the calibration are now stored in memory and all channel tip temperature settings are turned OFF All channel Tip Temperature Offset...

Страница 11: ...t calibration module is inserted H X X 1 thru 9 Indicates the Current Channel is ready to accept new Upper Temperature Limit setpoint X X times 100 F L X X 1 thru 9 Indicates the Current Channel is re...

Страница 12: ...12...

Отзывы:

Похожие инструкции для MBT250