11
DISPLAY
DISPLAY
DISPLAY
DISPLAY
MESSAGE
MESSAGE
MESSAGE
MESSAGE
DESCRIPTION
DESCRIPTION
DESCRIPTION
DESCRIPTION
C-1 OR C-2
Indicates system is ready to process Digital Readout accuracy
calibration for a particular channel using the appropriate
calibration module.
CAL
Indicates that system is in the Calibration Mode.
E-5
Input to control circuitry unstable. Indicates that no calibration
module is connected to the channel being calibrated or the
incorrect module has been inserted.
E-6
Loose connection. Calibration input is out of range. Normally
occurs if incorrect calibration module is inserted.
H-X
(X = 1 thru 9)
Indicates the Current Channel is ready to accept new Upper
Temperature Limit setpoint X (X times 100°F).
L-X
(X = 1 thru 9)
Indicates the Current Channel is ready to accept new Lower
Temperature Limit setpoint X (X times 100°F).
OFF
Setpoint for this channel is below Lower Temperature Limit
setpoint.
S--
Indicates that the Automatic Temperature Setback (and Power
Down) feature is disabled (turned off).
S-X
Indicates that the Automatic Temperature Setback (and Power
Down) feature is enabled (turned on) and will set each channels'
Set Tip Temperature back after X times 10 minutes of handpiece
inactivity (non-use).
---
(flashing)
Indicates that the system circuitry is proceeding with calibration
using the proper calibration module (C-1 or C-2).