The Set Temperature can only be within the set temperature limits. If the lower limit
is reached, the display will read off. If the upper limit has been reached, the display
will read “HiL”. Temperature limits can be adjusted in the programming menu. See
“Programming Your System” section.
5. Observe the Digital Readout as the temperature reaches and stabilizes at the Set Tip
Temperature.
6. The system can be manually forced into Temperature Setback by pressing and holding
the Scroll Down (
t
) Key and the Scroll Up
Key.
7. When the display begins to blink, the system is in Temperature Setback mode and will
reduce the set temperature to 177°C (350°F).
NOTE:
If Auto Off has been enabled in
the programming menu, the system will enter Auto Off (temperature Off and LED Display
flashing "Off") after the preset time of handpiece inactivity. Auto Off can be exited by
pressing any key.
8. To exit Temperature Setback mode, perform any one of the following:
a) Press and release a Key (
,
or
). This is the preferred method.
b) Wipe the hot handpiece tip on a wet sponge to thermally load the tip.
c) Turn the Power Switch Off ("0") and then back on ("I").
9. The system is now in normal operation. Observe the LED Display as the tip temperature
reaches and stabilizes at the Set Temperature. Allow time for the temperature to
stabilize at the Set Temperature before using.
NOTE:
Read the “Programming Your System” sections of this manual to utilize the full
capabilities of the system.
LED Display, Normal Operation
The LED Display provides a 3-digit display of temperature information. The LED Display will show:
1. A display of "888" on initial power up to ensure that all LEDs on the display are
working.
2. A display of the software version of the installed microprocessor (e.g., "1-1") for 1
second on initial power up after the "888" is displayed.
3. Actual tip temperature of the connected handpiece during normal operation. The
tip temperature displayed will flash when the system is in Temperature Setback.
4. The displayed temperature will decrease and stabilize at 177°C (350°F) when the
system is in Temperature Setback.
5. "OFF" when the Set Tip Temperature has been set to Off (below minimum set tip
temperature). Refer to the "Programming Your System" portion of this manual.
6. "OFF" plus the LED Display will be flashing when the unit has entered Auto Off.
Refer to the "Programming Your System" section of this manual.
7. Error messages ("OSE" or “CEE”) if a system fault is detected. Refer to the
"Corrective Maintenance" portion of this manual.
LED Display, Temperature Adjust Mode
The LED Display will show the following when adjusting the desired Set Tip Temperature.
1. The Set Tip Temperature.
2. "HiL" (High Temperature Limit) when adjusting the set tip temperature and the
maximum allowable temperature is exceeded. Refer to the "Programming Your
System" portion of this manual.
3. "OFF" (Low Temperature Limit) when adjusting the set tip temperature and the
minimum allowable temperature is exceeded. Refer to the "Programming Your
System" section of this manual.