©2005 PACE Inc., Annapolis Junction, Maryland
Page 8 of 17
All Rights Reserved
Program/
Menu Button
3. The LED indicator will turn amber while the tip is heating to the desired performance level.
4. Once the tip has reached the desired heat level, the LED indicator will turn green and the
system is ready to use.
Auto-Setback and Auto-Off Features
The HW 50 system comes standard with Auto-Setback and Auto-Off Features. These are pre-
programmed for 30 minute Setback and 30 minute Auto Off, which can be turned off by the switch on
the back of the unit. When Setback mode has been entered, the heat level will be adjusted to 3.5.
The following chart explains the function of the LED Indicator Light.
LED Indicator Activity
Power On
Amber
Æ
Green
Normal Operation
Green
Tip Cartridge Removed
Red
Heater Open Sensor
Red
System In SetBack
Amber or Green*
System in Auto-Off
System reactivated after Auto-Off
Amber
Æ
Green*
*The LED will be Amber or Green depending on the color when it entered Setback, or Auto Off.
TW 50 TempWise System
The TW 50 system is very easy to adjust and operate. The following instructions detail system
features and operation of the system. Information regarding changing of system options (e.g.,
Temperature Setback time, Auto Off) is contained in the "Programming Your System" portion of this
manual.
1. Ensure that the Set-Up procedure has been performed.
Verify the following:
a) Handpiece connection to the power source.
b) Proper tip installed in handpiece.
c) Power cord connection between an
appropriate
AC supply and the power source.
2. Turn the Power Switch On ("I"). The
display will begin to increase as the TD 100
handpiece heats up.
3. Press the Scroll Up
Key. The Set
Temperature is now displayed, immediately perform step
4.
NOTE:
If a Password has been previously programmed into the system, "EP" will be appear
on the LED Display at this point. When this message appears, the operator must
enter the correct Password before adjusting the temperature.
4. Adjust the temperature by pressing and holding Scroll Up
Key or Scroll Down
key.
Observe the display as the Set Temperature increases first in increments of 5°, then in
increments of 10°. When the desired temperature is reached, release the key.
LED
Indicator
Scroll Up/Down
Buttons