4
Specifications
System Power Source Power Requirements
The system power sources are available in either the 115 VAC, 230 VAC or 100 VAC
version as listed below.
PPS 15A (ST 20A system) -
Operates on 97-127 VAC, 50/60Hz, 90 Watts
maximum at 115 VAC, 60Hz
PPS 15AE (ST 20AE system) -
Operates on 197-264 VAC 50/60Hz, 80 Watts
maximum at 230 VAC, 50Hz
PPS 15AJ (ST 20AJ system) -
Operates on 90-115 VAC 50/60Hz, 80 Watts
maximum at 100 VAC, 50/60Hz
Temperature Specifications
Handpieces
Tip Temperature Range
93°C to 482°C (200°F to 900°F) nominal.
Temperature Stability
±1.1°C (±2°F) at idle from set tip temp.
PS 50 Prep-Set
Temperature Range
93°C to 371°C (200°F to 700°F) nominal.
NOTE - Actual minimum and maximum Operating Tip Temperatures may
vary depending on Handpiece (or PS 50), Tip Selection and application.
EOS/ESD Specifications
The specifications shown below apply except on "Soft Ground Systems" which have
a 1 meg ohm current limiting resistance and a label placed on the power source front
panel referring to EN 100015-1.
Tip-To-Ground Resistance
Less than 5 ohms.
AC Leakage
Less than 2 Millivolts RMS from 50Hz to 500Hz.
General Information