3.4 Safety Tests
!
Examine and verify that the
MEGA
-
T400S
safety
devices and operating performance are in good working
condition before use. The following safety checks are
considered significant:
Emergency stop switch
Magnetic Safety switch
11
Test:
Activate the main switch and the close
hood; depress emergency stop switch.
Proper
Response
:
Machine powers down and motor
stops in 5
-
10 seconds
Malfunction:
Machine does not lose power.
Corrective
measure:
If system does not power down,
disconnect power supply cord and call
service technician.
Magnetic safety lock out switch
Test:
Activate the main switch and close the
hood; turn cut
-
off wheel ON then OFF;
Try to open the hood.
Proper
Response:
The hood does not open for approxi-
mately 3
-
5 seconds.
Malfunction:
If hood opens immediately.
Corrective
measure:
If the cut
-
off wheel does not power
down, disconnect the power supply cord
and call a service technician.
Emergency stop switch
HOOD (Closing / Opening)
1.
When closing the hood, press down on the hood to ensure
that the safety switch is engaged
.
2.
If the hood lock does not unlock
DO NOT FORCE OPEN,
or
try pushing down on the hood to release the safety pin.