4-3
Section 4
PTO Mounting & Programming
9/18
AUTOMATIC TRANSMISSIONS
On Allison transmissions there are two locations for PTO’s. The Allison 4000 series has PTO locations at 1 and 8 o’clock
viewed from the back of the transmission. The 4000HS transmissions do not have any PTO locations. The 3000 series Al-
lison transmissions have PTO locations at 4 and 8 o’clock. For more information on using PTO’s with an Allison transmis-
sion go to www.allisontransmission.com and refer to the “Rugged Duty Series Brochure” and “PTO Request Flyer” which is
available in a 1000/2000 version and a 3000/4000 version.
Some PTO configurations will have clearance issues with other components on the truck. With manual transmissions, a
6-bolt PTO on the right will typically clear most components when the DPF and SCR are under the cab. This is also true
when 30 and 45 degree adapters are used. The 8-bolt bottom mount PTO will not have any issues unless you are running
a driveshaft back to another component and the truck has a crossover style exhaust. In this case, the DPF and SCR would
block any routing for the driveshaft. If a wet kit is used in this scenario there is enough room to mount the PTO and the hy-
draulic pump without interfering with the exhaust. On Allison 4000 series transmissions, most PTO’s will fit in the 1 o’clock
position without interfering with the cab. If a wet kit is used here, the dipstick housing will most likely need to be modified
as it runs over the top of the transmission to the driver side of the vehicle. The PTO in the 8 o’clock position is typically ok.
The same issue with crossover exhaust would apply here as well. There are some scenarios where the PTO will be very
close to or could interfere with the rear spring shackle on the front suspension. This problem can occur on vehicles with a
set-back front axle and the problem is amplified on the short hood models.
FIGURE 4-2. Allison 4000 Series
FIGURE 4-3. Allison 3000 Series
Содержание Kenworth T680 2019
Страница 1: ...Kenworth Heavy Duty Body Builder Manual 2019 ...
Страница 2: ...This page intentionally left blank ...
Страница 3: ...Kenworth Heavy Duty 2 1m Cab Body Builder Manual ...
Страница 12: ...This page intentionally left blank ...
Страница 22: ...This page intentionally left blank ...
Страница 77: ...4 7 Section 4 PTO Mounting Programming 9 18 Allison Transmission ...
Страница 108: ...2 17 5 22 Section 5 Exhaust Aftertreatment This page intentionally left blank ...
Страница 144: ...8 8 2 17 Section 8 Frame Modifications This page intentionally left blank ...
Страница 155: ...10 5 9 18 Section 10 Electrical Chassis Node Figure 10 3 Electrical Harness Overview ...
Страница 162: ...10 12 9 18 Section 10 Electrical FIGURE 10 14 MX 11 and MX 13 Connector Location ...
Страница 164: ...10 14 9 18 Section 10 Electrical FIGURE 10 16 X15 Connection location FIGURE 10 17 ISX12 Connection location ...
Страница 165: ...10 15 9 18 Section 10 Electrical FIGURE 10 18 Power Distribution Center ...
Страница 166: ...10 16 9 18 Section 10 Electrical FIGURE 10 19 Engine Side Fuse Box Full Content Population ...
Страница 167: ...10 17 9 18 Section 10 Electrical FIGURE 10 20 Dash Side Fuse Box Full Content Population ...
Страница 171: ...10 21 9 18 Section 10 Electrical FIGURE 10 24 Overview Layout FIGURE 10 25 ...
Страница 177: ...10 27 9 18 Section 10 Electrical FIGURE 10 36 Spare circuit location on Power Distribution Center Dash Side P001 ...
Страница 178: ...10 28 9 18 Section 10 Electrical FIGURE 10 37 Spare circuit diagram P001 and P096 ...
Страница 182: ...10 32 9 18 Section 10 Electrical FIGURE 10 41 Telltale Installation Diagnostics Service Tool Connection ...
Страница 193: ...A 5 2 17 Appendix A Vehicle Identification This page intentionally left blank ...
Страница 194: ...A 6 2 17 Appendix A Vehicle Identification Kenworth Truck Company P O Box 1000 Kirkland WA 98083 425 828 5000 ...