 BEFORE YOU BEGIN

Read these instructions completely and carefully. 

IMPORTANT

- Save these instructions.

IMPORTANT

- Observe all governing codes  

and ordinances.

Note to Installer

- Be sure to leave these instructions with 

the Consumer.

Note to Consumer

- Keep these instructions for  

future reference.

Skill level

- Installation of this appliance requires basic 

mechanical skills.

Completion time

- Approximately 1 hour.

We recommend that two people install this product.
Proper installation is the responsibility of the installer.
Product failure due to improper installation is not 

covered under the Warranty.
You MUST use all supplied parts and use proper 

installation procedures as described in these 

instructions when installing this air conditioner.

 WINDOW REQUIREMENTS

Your air conditioner is designed to install in standard 

double hung windows with opening widths of 23 to 36 

inches (584 mm to 914 mm).

Inner sill

Offset

Window

Sill
Exterior

Interior wall

23–36 in.

13 in.

Sash

CAUTION

DO NOT

, under any circumstances, cut or remove the 

third (ground) prong from the power cord.

DO NOT

 change the plug on the power cord of the air 

conditioner.
Aluminum house wiring may present special problems- 

consult a qualified electrician.
When handling unit, be careful to avoid cuts from sharp 

metal edges and aluminum fins on front and rear coils.

TOOLS YOU WILL NEED

●  Phillips Screwdriver

●  Level

TOOLS YOU MAY NEED

●  Flathead Screwdriver

●  Pencil

●  Ruler or Tape Measure

●  Scissors or Knife

HARDWARE

Included - packed with the unit.

(Included - Packed with the Unit)

3/4ʺ (or 1/2ʺ)

Screws

3/4

ʺ

 (or 1/2

ʺ

)

Screws (7 pcs)

Lock Frame

(2 pcs)

Sash Lock

(1 pc)

Window 

Sash Seal 

Foam (1 pc)

Weather Stripping

10

ʺ

x

3

/

4

ʺ

x

1

/

12

ʺ

(5 pcs)

7 pcs

Lock Frame

3/4

ʺ

 (or 1/2

ʺ

)

Screws (7 pcs)

Lock Frame

(2 pcs)

Sash Lock

(1 pc)

Window 

Sash Seal 

Foam (1 pc)

Weather Stripping

10

ʺ

x

3

/

4

ʺ

x

1

/

12

ʺ

(5 pcs)

2 pcs

Sash Lock

1 pc

Window Sash Seal 

Foam

3/4

ʺ

 (or 1/2

ʺ

)

Screws (7 pcs)

Lock Frame

(2 pcs)

Sash Lock

(1 pc)

Window 

Sash Seal 

Foam (1 pc)

Weather Stripping

10

ʺ

x

3

/

4

ʺ

x

1

/

12

ʺ

(5 pcs)

1 pc

3/8ʺ Screws

3/8" Screws

(4 pcs)

Top Rail

(1 pc)

Insulation 

Panels (2 pcs)

4 pcs

Top Rail

3/8" Screws

(4 pcs)

Top Rail

(1 pc)

Insulation 

Panels (2 pcs)

1 pc

Accordion Panels 

(one left, one right)

1 set

INSTALLATION INSTRUCTIONS

Содержание 4PMC5000

Страница 1: ...WINDOW AIR CONDITIONER FOR MODEL 4PMC5000 Before using your air conditioner please read this manual carefully and keep it for future reference along with your receipt USER MANUAL ...

Страница 2: ...____________________________ Purchase Date _____________________________________ Store Purchased ______________________________________ Installation Date ____________________________________ Installation Co _______________________________________ Installer Name ______________________________________ Installer Phone No ____________________________________ CONSUMER PRODUCT INFORMATION ...

Страница 3: ...stallation of this unit if necessary The air conditioner is not intended for use by young children without adult supervision Young children should be supervised to ensure that they do not play with the air conditioner Disabled persons may require assistance with set up If the power cord is to be replaced replacement work should be performed by authorized personnel only Installation and repair work...

Страница 4: ...m the unit Failure to do so may cause fire and electric shock DO NOT use the socket if it is loose or damaged Doing so may cause fire and electric shock DO NOT open the unit during operation Doing so may cause electric shock DO NOT use firearms near unit Doing so may cause fire DO NOT use the power cord close to heating appliances Doing so may cause fire and electric shock DO NOT disassemble modif...

Страница 5: ...od of time unplug or turn OFF main power switch Leaving power on may cause unit failure or fire DO NOT place obstacles around air inlets or inside of air outlet Obstacles may cause appliance failure or accident Periodically check installation bracket for damage Prolonged exposure to outdoor elements may cause damage to installation bracket causing unit to fall Always insert filter s securely Clean...

Страница 6: ...e sure the air conditioner has been securely and correctly installed according to the installation instructions in this manual Save this manual for possible future use in removing or installing this unit When handling the air conditioner be careful to avoid cuts from sharp metal fins on front and rear coils WARNING ELECTRICAL INFORMATION The complete electrical rating of your new room air conditio...

Страница 7: ...n Sash CAUTION DO NOT under any circumstances cut or remove the third ground prong from the power cord DO NOT change the plug on the power cord of the air conditioner Aluminum house wiring may present special problems consult a qualified electrician When handling unit be careful to avoid cuts from sharp metal edges and aluminum fins on front and rear coils TOOLS YOU WILL NEED Phillips Screwdriver ...

Страница 8: ...with the 3 8 screws as shown in Fig C NOTE For safety reasons all four 4 screws MUST be securely fastened STEP 3 INSTALLING THE WINDOW A C NOTE Top rail and sliding panels on each side are offset to provide the proper pitch of 5 16 to the rear This is necessary for proper condensed water utilization and drainage If you are not using the side panels for any reason this pitch to the rear must be mai...

Страница 9: ... tilted back approximately 5 8 to 3 4 Fig 5 above tilted about 3 to 4 downward to the outside If after proper installation condensation does not drain from the overflow drain hole during normal use adjust slope B Extend the side panels out against the window frame Fig 6 STEP 5 INSTALL SUPPORT BRACKET A Place the frame lock between the frame extensions and the window sill as shown in Fig 7 Drive 3 ...

Страница 10: ...ation must be allowed to drain out REMOVING AC FROM WINDOW Turn AC off and disconnect power cord Remove sash seal from between windows and unscrew safety sash lock Remove screws installed through frame and frame lock Close slide side accordion panels into frame Keeping a firm grip on air conditioner raise sash and carefully remove Be careful not to spill any remaining water while lifting unit from...

Страница 11: ...igh efficiency compressors may have a high pitched chatter during the cooling cycle SOUND OF RUSHING AIR At the front of the unit the sound of rushing air being moved by the fan may be heard GURGLE HISS Gurgling or hissing noise may be heard due to refrigerant passing through evaporator during normal operation NOTE All of the pictures in this manual are for explanatory purposes only The actual sha...

Страница 12: ...as needed Move the Lever s from side to side until the desired Left Right direction is obtained CONTROL PANEL The controls featured in this manual are representative of many available models Your model may offer slightly different features COOL MODE The desired cool setting is selected by rotating the Cooling knob to the appropriate location HI COOL has a maximum cooling effect and airflow LO COOL...

Страница 13: ... use hot water over 104 F 40 C to clean the air filter Never attempt to operate the unit without the air filter CABINET CLEANING Be sure to unplug the air conditioner to prevent shock or fire hazard The cabinet and front may be dusted with an oil free cloth or with a cloth dampened in a solution of warm water and mild liquid dishwashing detergent Rinse thoroughly and wipe dry Never use harsh clean...

Страница 14: ...oil set to FAN only mode Then set temperature to a higher setting AIR CONDITIONER CYCLING ON AND OFF TOO FREQUENTLY OR NOT ENOUGH Be sure unit is not too large or too small for the area of the room Remove grille and make sure the temperature sensor is not too close to the coils These two elements should not be touching Carefully straighten tube away from coil Make sure nothing is blocking the gril...

Страница 15: ...The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details ...

Страница 16: ... 5151 Belt Line Rd Suite 878 Dallas TX 75254 Distributed by 844 4PA AIRE 844 472 2473 www perfectaire us Specification and performance data is subject to change without notice Printed in China PA User_4PMC5000 10172017 ...

Отзывы: