 STEP 1:

PREPARE THE WINDOW

Lower sash must open sufficiently to allow a clear 

vertical opening of 13 inches (330 mm). Side louvers 

and the rear of the AC must have clear air space to 

allow enough airflow through the condenser for heat 

removal. The rear of the unit must be outdoors, not 

inside a building or garage.

MOUNTING HARDWARE:

3/4" (or 1/2")

Screws (7 pcs)

Lock Frame

(2 pcs)

Sash Lock

(1 pc)

Window 

Sash Seal 

Foam (1 pc)

Weather Stripping

10"x

3

/

4

"x

1

/

12

"

(5 pcs)

 

 STEP 2: 

PREPARE AIR CONDITIONER

A.

 Remove the air conditioner from the carton and 

place on a flat surface.

B.

  Remove top rail from the rear of the packaging 

material as shown in Fig. A. 

TOP RAIL HARDWARE:

3/8" Screws

(4 pcs)

Top Rail

(1 pc)

         

C.

  Align the hole in the top rail with those in the top of 

the unit as shown in Fig. B.

D.

 Secure the top rail to the unit with the 3/8″ screws 

as shown in Fig. C.

NOTE: 

For safety reasons, all four (4) screws MUST be 

securely fastened.

 STEP 3:

INSTALLING THE WINDOW A/C

NOTE: 

Top rail and sliding panels on each side are 

offset to provide the proper pitch of 5/16″ to the 

rear. This is necessary for proper condensed water 

utilization and drainage. If you are not using the  

side panels for any reason, this pitch to the rear must 

be maintained.

A.

 Place unit on floor, a bench or a table. There is one 

left and one right side filler panel. Be sure to use 

the proper panel for each side. When installed, the 

flange for securing the panel to the window sill will 

be facing into the room.

C

.  Slide the free end “   ” section of the panel directly 

into the cabinet as shown in Fig. 2. Slide the  

panel down. Be sure to leave enough space to slip 

the top and bottom of the frame into the rails on 

the cabinet.

" "

  

FIG. A

Packaging

Top Rail

FIG. C

FIG. B

FIG. 1

FIG. 2

B

. Hold the accordion panel 

in one hand and gently pull 

back the center to fill the 

open end. See Fig. 1.

Содержание 4PMC5000

Страница 1: ...WINDOW AIR CONDITIONER FOR MODEL 4PMC5000 Before using your air conditioner please read this manual carefully and keep it for future reference along with your receipt USER MANUAL ...

Страница 2: ...____________________________ Purchase Date _____________________________________ Store Purchased ______________________________________ Installation Date ____________________________________ Installation Co _______________________________________ Installer Name ______________________________________ Installer Phone No ____________________________________ CONSUMER PRODUCT INFORMATION ...

Страница 3: ...stallation of this unit if necessary The air conditioner is not intended for use by young children without adult supervision Young children should be supervised to ensure that they do not play with the air conditioner Disabled persons may require assistance with set up If the power cord is to be replaced replacement work should be performed by authorized personnel only Installation and repair work...

Страница 4: ...m the unit Failure to do so may cause fire and electric shock DO NOT use the socket if it is loose or damaged Doing so may cause fire and electric shock DO NOT open the unit during operation Doing so may cause electric shock DO NOT use firearms near unit Doing so may cause fire DO NOT use the power cord close to heating appliances Doing so may cause fire and electric shock DO NOT disassemble modif...

Страница 5: ...od of time unplug or turn OFF main power switch Leaving power on may cause unit failure or fire DO NOT place obstacles around air inlets or inside of air outlet Obstacles may cause appliance failure or accident Periodically check installation bracket for damage Prolonged exposure to outdoor elements may cause damage to installation bracket causing unit to fall Always insert filter s securely Clean...

Страница 6: ...e sure the air conditioner has been securely and correctly installed according to the installation instructions in this manual Save this manual for possible future use in removing or installing this unit When handling the air conditioner be careful to avoid cuts from sharp metal fins on front and rear coils WARNING ELECTRICAL INFORMATION The complete electrical rating of your new room air conditio...

Страница 7: ...n Sash CAUTION DO NOT under any circumstances cut or remove the third ground prong from the power cord DO NOT change the plug on the power cord of the air conditioner Aluminum house wiring may present special problems consult a qualified electrician When handling unit be careful to avoid cuts from sharp metal edges and aluminum fins on front and rear coils TOOLS YOU WILL NEED Phillips Screwdriver ...

Страница 8: ...with the 3 8 screws as shown in Fig C NOTE For safety reasons all four 4 screws MUST be securely fastened STEP 3 INSTALLING THE WINDOW A C NOTE Top rail and sliding panels on each side are offset to provide the proper pitch of 5 16 to the rear This is necessary for proper condensed water utilization and drainage If you are not using the side panels for any reason this pitch to the rear must be mai...

Страница 9: ... tilted back approximately 5 8 to 3 4 Fig 5 above tilted about 3 to 4 downward to the outside If after proper installation condensation does not drain from the overflow drain hole during normal use adjust slope B Extend the side panels out against the window frame Fig 6 STEP 5 INSTALL SUPPORT BRACKET A Place the frame lock between the frame extensions and the window sill as shown in Fig 7 Drive 3 ...

Страница 10: ...ation must be allowed to drain out REMOVING AC FROM WINDOW Turn AC off and disconnect power cord Remove sash seal from between windows and unscrew safety sash lock Remove screws installed through frame and frame lock Close slide side accordion panels into frame Keeping a firm grip on air conditioner raise sash and carefully remove Be careful not to spill any remaining water while lifting unit from...

Страница 11: ...igh efficiency compressors may have a high pitched chatter during the cooling cycle SOUND OF RUSHING AIR At the front of the unit the sound of rushing air being moved by the fan may be heard GURGLE HISS Gurgling or hissing noise may be heard due to refrigerant passing through evaporator during normal operation NOTE All of the pictures in this manual are for explanatory purposes only The actual sha...

Страница 12: ...as needed Move the Lever s from side to side until the desired Left Right direction is obtained CONTROL PANEL The controls featured in this manual are representative of many available models Your model may offer slightly different features COOL MODE The desired cool setting is selected by rotating the Cooling knob to the appropriate location HI COOL has a maximum cooling effect and airflow LO COOL...

Страница 13: ... use hot water over 104 F 40 C to clean the air filter Never attempt to operate the unit without the air filter CABINET CLEANING Be sure to unplug the air conditioner to prevent shock or fire hazard The cabinet and front may be dusted with an oil free cloth or with a cloth dampened in a solution of warm water and mild liquid dishwashing detergent Rinse thoroughly and wipe dry Never use harsh clean...

Страница 14: ...oil set to FAN only mode Then set temperature to a higher setting AIR CONDITIONER CYCLING ON AND OFF TOO FREQUENTLY OR NOT ENOUGH Be sure unit is not too large or too small for the area of the room Remove grille and make sure the temperature sensor is not too close to the coils These two elements should not be touching Carefully straighten tube away from coil Make sure nothing is blocking the gril...

Страница 15: ...The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details ...

Страница 16: ... 5151 Belt Line Rd Suite 878 Dallas TX 75254 Distributed by 844 4PA AIRE 844 472 2473 www perfectaire us Specification and performance data is subject to change without notice Printed in China PA User_4PMC5000 10172017 ...

Отзывы: