The blind is moving up (opening)
The blind is moving down (closing)
The blind is partly open. With the new firmware version the position is also
displayed. (e.g. 52% open)
Controlling the blinds is also possible via this web page:
Clicking on the “up arrow” icon will start moving the blind up (opening).
Clicking on the “down arrow” icon will start moving the blind down (closing).
Clicking on this icon will stop the blind at the current position.
Operation via TCP
To achieve the easiest integration with most controllers used in home and commercial
applications, the module can be controlled by raw TCP protocol using simple ASCII based
commands.
The TCP/IP communication can be enabled/disabled via the Network settings screen.
There are TCP commands for:
Turning an output On/Off, Toggling an output, turning an output on for a certain time,
querying the status of the inputs and outputs, setting and retrieving the mode of inputs, etc.
There are commands for:
Starting the motor to move up/down, toggle the motor’s direction, stopping the motor,
retrieve the motor’s (blind’s) position, retrieve if the motor is in motion, query the status of
the inputs, set and query the mode of inputs, set and query the motor running time in both
directions, move the motor up/down by a certain amount (%) or for a certain duration, etc.