1. 

Motor 1. Up Out 

27. 

Motor 1. Up Input 

2. 

Neutral 

28. 

Inputs common 

3. 

Motor 1. Down Out 

29. 

Motor 1. Down Input 

4. 

Motor 2. Up Out 

30. 

Motor 2. Up Input 

5. 

Neutral 

31. 

Inputs common 

6. 

Motor 2. Down Out 

32. 

Motor 2. Down Input 

7. 

Motor 3. Up Out 

33. 

Motor 3. Up Input 

8. 

Neutral 

34. 

Inputs Common 

9. 

Motor 3. Down Out 

35. 

Motor 3. Down Input 

10. 

Motor 4. Up Out 

36. 

Motor 4. Up Input 

11. 

Neutral 

37. 

Inputs common 

12. 

Motor 4. Down Out 

38. 

Motor 4. Down Input 

13. 

Power for Motors Live 

39. 

Power for the Inputs GND 

14. 

Power for Motors 
Neutral 

40. 

Power for the 12V (FNIP-
4xSH-12) or +24V (FNIP-4XSH-
24) 

 

 

41. 

Power for the Main Circuitry GND 

 

 

42. 

Power for the Main Cir12V 
FNIP-4xSH-12) or +24V (FNIP-
4xSH-24) 

Содержание FutureNow FNIP-4xSH-12

Страница 1: ...torized window coverings such as shades shutters blind curtains awnings or projection screens and any other devices equipped with four wire bidirectional AC motors with built in limit switches either...

Страница 2: ...TURES Robust Operation Ideal for motorized window coverings projection screens awnings etc 4 outputs for controlling 4 four wire up down neutral bidirectional AC motors 4x2 up down galvanically isolat...

Страница 3: ...trollers from most major vendors Control4 AMX etc Interoperable with any momentary contact switches available on the market INSTALLATION WARNING Since the module is connected to line voltage the insta...

Страница 4: ...9 Motor 1 Down Input 4 Motor 2 Up Out 30 Motor 2 Up Input 5 Neutral 31 Inputs common 6 Motor 2 Down Out 32 Motor 2 Down Input 7 Motor 3 Up Out 33 Motor 3 Up Input 8 Neutral 34 Inputs Common 9 Motor 3...

Страница 5: ...cross terminals 13 and 14 motors with different power requirements can also be used but all four motor has to be have the same power requirement After making all connections check if the outputs work...

Страница 6: ...ts offer not recommended you can use the same power to supply both the main circuitry and the inputs In that case simply connect terminal 39 to terminal 41 and terminal 40 to terminal 42 Ethernet conn...

Страница 7: ...input terminals for this purpose See section Power Requirements if you don t want to use two separate power supply units To assure an additional level of safe and reliable operation the inputs are als...

Страница 8: ...The red LED indicates the direction of the movement It is off while the motor is moving up and on while the motor is moving down If the motor is not in motion this LED is off Input status LEDs Each ch...

Страница 9: ...face Use the FNIP Network Discovery Utility software to find all FutureNow IP devices on your network Connecting to the module s web site After the scan is over you can click on one of the modules fou...

Страница 10: ...and functions The default user name is admin The default password is futurenow Once logged in you will automatically be directed to the control page There is a menu on the top of each web page to navi...

Страница 11: ...users and setting up user rights Three different users can be defined each with three different user rights admin actor and observer Admins have access to all functionality including control of the o...

Страница 12: ...2014 12 Observers are allowed to monitor the status of inputs and outputs but not allowed to control the outputs nor can they change any settings To modify user settings click on User in the top menu...

Страница 13: ...___________________________________________ FutureNow FNIP 4xSH Installation Manual rev 15 01 2014 13 Board configuration Clicking on Board in the top menu takes you to the board configuration page wh...

Страница 14: ...nput modes and how they work see Operation via local inputs paragraph of this document below Updating the firmware is also possible via this page Logging out You can log out from the module s web page...

Страница 15: ...ermediate position Activating the input for the opposite direction while the motor is still moving will cause the motor to change its direction after a short delay You can also move the motor to the d...

Страница 16: ...ual rev 15 01 2014 16 Figure 9 Control Page Each input can either be active input terminals shorted or inactive input terminals open A grey icon means that the corresponding input is inactive An activ...

Страница 17: ...hieve the easiest integration with most controllers used in home and commercial applications the module can be controlled by raw TCP protocol using simple ASCII based commands The TCP IP communication...

Страница 18: ...al purpose controllers there are many applications for embedded industrial PC boards PCs and smartphones running Linux Windows Mac OS Firmware upgrade Upgrading the firmware of the module is possible...

Страница 19: ...Terminals Type Screw terminals for max 2 5 mm2 wires Communication 10Mb s Ethernet via RJ45 Ethernet connector Simple ASCII based TCP commands via port 7078 by default Number of socket connections tha...

Страница 20: ..._____________________________________________________________________________ FutureNow FNIP 4xSH Installation Manual rev 15 01 2014 20 REFERENCES FNIP Search Utility FNIP 4xSH TCP Communication Proto...

Отзывы: