background image

20 

 

 

 

 

Changing Oil

 

•  Place generator on a level surface. 
•  Run the generator for several minutes until the engine is warm. Turn off generator. 
•  Remove screws, then remove outer casing. 
•  Remove the crankcase dipstick. 
•  Place an oil pan underneath the engine. Tilt generator to collect used oil. Allow oil to drain completely. 
•  Return generator to a level surface. 
• 

 

(Crankcase Dipstick hole).

 

•  Use a clean rag to wipe up any spilled oil. 
•  Replace crankcase dipstick. 
•  Reinstall outer casing and tighten screws. 

 

Recommended Engine Oil: 

SAE 10W-30

 

Recommended Engine Oil Grade: 

API Service SE type or higher quality of engine oil.

 

Engine Oil Quantity: 

0.35L (0.924 US gal)

 

 

 

 

 

 

MAINTENANCE 

the engine.

 

CAUTION!

 

Make sure no foreign matter enters the crankcase

 

CAUTION!

 

Содержание P2000i

Страница 1: ...2 FOR YOUR SAFETY You must read and understand this manual before use Keep this manual for future reference P1PE INVERTER GENERATOR P2000i P2000iS P2500i P2500iS User Manual...

Страница 2: ...ctrical System 11 Adding Fuel 11 Adding Checking Oil 12 Operation 13 Grounding the Generator 13 How to Start Engine 13 How toStop Engine 14 Attaching Electronic Devices 14 Charging a 12 Volt Battery 1...

Страница 3: ...s Generator specification MODEL P2000i P2000iS P2500i P2500iS Rated AC Voltage V 110V 120V 220V 230V 240V Rated Frequency Hz 50Hz 60Hz Rated Power kW 1 6 1 6 2 0 2 0 Starting Power kW 2 0 2 0 2 5 2 5...

Страница 4: ...Using a generator indoors WILL KILL YOU INMINUTES Carbon monoxide gas isa poisonous odorlessgas thatcan causeheadache confusion fatigue nausea fainting sickness seizures ordeath Ifyou start toexperien...

Страница 5: ...thegenerator and or connected electricaldevices WARNING When adding or draining fuel unit should be turned off for at least 2 minutes to cool before removing fuel cap If unit has been running then the...

Страница 6: ...uitinterrupter GFCI orRCD inadamporhighlyconductivearea suchasmetaldeckingor steel work Neverplugelectronicdevicesintogeneratorhaving frayed worn orbare wires Never touchbare wiresormake contact with...

Страница 7: ...Oil Warning Light K Overload Indicator Light P1 120VACOutlet Q ParallelOutlets R Ground Terminal D Outer Casing Side Panel E Handle Grip F Air Vent G FuelCap H Recoil Starter L AC Pilot Light M 3in1S...

Страница 8: ...gine Overload Indicator Light Iftheengineoverloadindicatorlightcomeson thegenerator swattage amperagecapacityhasbeenexceededbyconnectedelectrical devicesorbyapowersurge Whenthisoccurs thegreenACPilot...

Страница 9: ...nit automatically determines the generator s properengine speed basedon the connectedelectronicload Thisresults in superior fueleconomyand reduces noise When the ECO switch is turned to the OFF positi...

Страница 10: ...used to connect the generator to a driven ground rod Connect the ground terminal to the driven ground rod with a No 8 AWG American Wire Gage copper wire The wire connects to the terminal between the...

Страница 11: ...tightly Do not smoke when adding fuel Turn cap counterclockwise to remove provide space for fuel expansion Neverhandlethegenerator electronicdevices oranycordwhilestandinginwater whilebarefoot orwhenh...

Страница 12: ...addthespecifiedamountof4 Cycleengineoil SAE10W 30 to empty reservoir until or oil reaches the outer edge of the oil fill hole crankcase dipstick hole Be sure to replace dipstick and securely tighten b...

Страница 13: ...nt to the ON position Turn the 3 in 1 Start Switch to CHOKE Pull recoil handle starter cord slowly until resistance is felt then pull rapidly Let engine run for several seconds and then gradually as e...

Страница 14: ...tacles are in good condition Make sure all electronic devices are turned OFF before plugging them into thegenerator 2 Start engine 3 If the attached load is small turn the ECO switch to the ON positio...

Страница 15: ...recommended to check the gravity level of the electrode at least once per hour with a hydrometer to preventovercharging and totest thebattery s condition Be careful to follow thehydrometermanufacture...

Страница 16: ...onic device is started the red overload indicator may come on Thisisnormal Ifthelightstaysondisconnectallelectronicdevicesandstoptheengine Referto EngineOverload Indicator Light on page8 OPERATION A f...

Страница 17: ...ial Arm Saw 2000 2000 Electric Drill HP 5 4 Amps 600 900 Don t Overload Generator Make sure you can supplyenough rated watts forallelectronic devices connectedto the generator Rated wattsreferto the p...

Страница 18: ...conditions Service Spark Plug 12 Months 300 hr Use Clean Fuel Filter Replace if necessary Check Crankcase Breather Hose for cracks or damage Replace if necessary De carbonize cylinder head See dealer...

Страница 19: ...ebrush Check the electrode gap and slowly adjust to 0 7 0 8mm 0 028 0 031 in ifnecessary Reinstall spark plug and tighten to Torque 20 0Nm 14 8ft lb Ifsparkplug isworn replace only with anequivalent r...

Страница 20: ...o collect used oil Allow oil to drain completely Return generator to a levelsurface Crankcase Dipstick hole Use a clean rag to wipe up any spilled oil Replace crankcase dipstick Reinstall outer casing...

Страница 21: ...uldbedamp butnotdripping Remove screws then remove shown area of outer casing Check the muffler screen and spark arrester for damage If damaged replace with Our replacement parts Install the outer cas...

Страница 22: ...air cooling slots Remove any debris if obstructed Store indoors and use a protective cover to protect from dust FUEL Forshort termstorage addfuelstabilizertopreventstalefuelfromcausingacidandgumdepos...

Страница 23: ...Start generator engine and letitrun untilit stops and allremaining fuel isconsumed Do not connect electronic devices to generator during thisprocess Remove outer casing screws then remove outer casing...

Страница 24: ...epartment 5 Contact servicedepartment Enginewillnotstart shutsdown during operation orstartsandrunsrough 1 3 in 1 switch set to OFF 4 Out of fuel or Stale fuel 5 Sparkplugwiredisconnectedfrom spark pl...

Страница 25: ...your local authority or recycling centre Certain products contain batteries which should not be disposed of in your domestic waste You MUST recycle batteries in accordance with your local authority or...

Страница 26: ...es 97 68 EC Non Road Mobile MachineryDirective 2000 14 EC Outdoor Noise Directive 2004 108 EC ElectroMagneticCompatibilityDevice 2006 42 EC Machinery Directive P2000i P2000iS 1 6kW P2500i P2500iS 2 0k...

Страница 27: ...oad PembrokeDock Pembrokeshire SA724RW UK Telephone 44 0 1646687880 Fax 44 0 1646686198 Website www p1pe co uk To register your machine for the manufacturer s warranty please visit http www p1pe co uk...

Страница 28: ...P1PE Position One Power Equipment IsaacWay PembrokeDock Pembrokeshire SA72 4RW www p1pe co uk www p1pe co uk...

Отзывы: