It is important that the area around the fan from which the air is extracted is kept
clear in order that the air can move freely. No persons are allowed to be in the area
since the airflow contains organic gas and dust.
There must not be any obstacles in front of the fan or behind the fan. It is
recommended than an area that is 3 x the size of the fan’s diameter is kept free,
1.5 times the size in front and behind, respectively.
Installation in a metal structure
If the fan is to be installed directly in a metal structure, use
M8 bolts of the type 8.8, which are screwed in the threaded
inserts on the fan’s panels. Two on each side.
Installation in a wooden structure
If the fan is to be installed in a wooden structure, it must be
equipped with an exterior iron frame (not included) with a
60 mm L-shaped profile with a thickness of at least 5 mm
and with suitable clamps.
When the frame is built in and adapted correctly, insert the
fan using four M8 bolts of the type 8.8 (not included),
screwed into the threaded inserts on the fan’s panels, two
on each side.