Appendix B - Maintenance
All major components requiring maintenance have guidelines listed in the respective operation manuals. Refer to
those individual operation manuals for other preventative maintenance and regular maintenance information.
Component
Action
Tim Interval
Part Number(s)
Compressed Air Filter
Replace filter element
3 months/as needed
PR-8: Replacement filter
Compressor Inlet Air Filter Replace inlet air filter
3 months/as needed
CP-Filter-4: Repl Element
Ozone Leak Sensor
Replace sensor
Annually
SEN-1
ORP Sensor
Replace sensor
Annually
ORP-Sensor
Dissolved Ozone Monitor
Replacement flat cap
Annually
AS- Flat Cap
Check Valves
Replace
Annually
CVLP-4 and CVHP-8
Air Compressor
Rebuild compressor
Annually
CP-OG Rebuild
ODS-1H Destruct Unit
Replace Catalyst
Annually
ODS-Catalyst
Injection Pump
Replace/rebuild pump
3-5 years
CM5-G Rebuild
Maintenance Table