OUV-2800-HF(T), OUV-4000-HF(T) & OUV-6800-HF(T)
Tube Removal & Cleaning Instructions ...Continued
6.Take all the tubes and use an alcohol moistened paper towel or a lightly soap and water moistened paper
towel to wipe the tubes down and remove any deposits. If soap water is used then a second wiping with
a clean water moistened paper towel will be required to remove the soap.
-Be very careful not to damage the 2 wires that run the length of the tubes
-Note that using alcohol will allow you to use the ozone generator as soon as it is re assembled.
-If water is used for cleaning allow tubes to dry in a warm place for a couple hours, ensure that they
completely dry.
7. If dirty, wipe the inside of the unit with an alcohol soaked paper towel.
8. Remove the filter by grasping the retaining ring and simply pulling it off of the fan grill.
9. Clean the foam filter with dish soapy water, and rinse thoroughly and allow to dry completely before re
installing. Replace the filter by clipping the retaining ring back on the fan grill.
10. Replace the tubes by inserting them with the 2 wires that run the length facing one side or the other.
Wiggle the tube slightly side to side while pushing until the pins are fully in the socket. Replace the wire
ties with new ones especially if the unit is to be shipped. Note that the wire ties are standard 3 1/2" wire
(cable) ties available at your local lumber store.
11. Replace the lid and re install the 18 lid screws. The unit is now ready for service.