OUV-2800-HF(T), OUV-4000-HF(T)  &  OUV-6800-HF(T)

Operation and Maintenance Instructions ...Continued

SETTING OF MACHINE 

 

 

(Standard Controls)

This switch setup is designed for shock treating using the provided
one shot shock treatment timer or daily/weekly shock treatments
using the 7 day timer if ordered. 
(Refer to ozone application/usage instructions for more detailed
instructions.)

1. 

This series has controls that feature an On/off switch to power

the unit and fan, a one shot timer to control the amount of time the
unit runs for, as well as 3 switches for controlling output in 5-7
steps (depending on model).  Ozone production begins when 1, 2,
or all 3 output switches, and either the power switch or the timer is
set to on. (Note, Do not turn on the power switch and the timer at
the same time)
2. The output switches control the output of the ozone generator by
turning only some lamps on. The 2800 has 5 UV tubes, switch 1
turns on 1 tube, switch 2 turns on 2 tubes. The 3 switch turns on
the remaining 2 UV tubes. This allows for operation at 5 different
output settings. The 4000 has 7 UV tubes, switch 1 turns on 1 tube, switch 2 turns on 2 tubes. The 3 switch turns
on the remaining 4 UV tubes. This allows for operation at 7 different output settings. The 6800 also have 3 output
switches, the first switch turns on 2 UV tubes, the second switch turns on 4 UV tubes, the third switch turns on the
remaining 6 UV tubes. This allows 6 different output settings.

3. 

This unit is designed exclusively for shock treatments.

4. 

TIMER OPERATION

Timer simply bypasses the on/off or Hi/Low switch.
To use/set the timer make sure the switch is in the OFF position. Follow the manufacturers timer instruction for
operation.

SETTING OF MACHINE 

 

 

(w/ Optional 7-Day Timer Controls)

1. 

This series has controls that feature a master On/off switch to

power the unit and fan, a digital timer to control the amount of
time the unit runs for each day and has 7 on and 7 off settings per
day. There are also 3 UV tube control switches under the power
switch, these switches allow you to control wether the UV tubes
are on continual operation or timed operation. To run continual set
switches to “Hold”, to run the tubes on timed operation set the
switches to “Timed”.

Examples: 

(1) If you turn the “2 Tubes” switch to the “Hold”

position, and the “4 Tubes” and “6 Tubes” switch to the “Timed”
position then you will have 2 tubes working continually and 10
tubes working on the timer.
(2) If you turn the “4 Tubes” switch to “Hold” and turn “2 Tubes” switch to “Timed” then 4 tubes will run
continually, and 2 tubes will operate on the timer and the 6 tubes will not run at all.

2. 

This unit is designed to allow some UV tubes to run constantly and also allow the rest to be turned on by a

timer for shock treatments.

3. 

TIMER OPERATION

Follow the manufacturers timer instruction for operation.