OUV-2800-HF(T), OUV-4000-HF(T) & OUV-6800-HF(T)
Operation and Maintenance Instructions
IMPORTANT!!!!!
1. Read instructions thoroughly before operating!!
2. After shipping the unit via courier or after rough handling such as falling off a shelf open cabinet by following
step 1 of the cleaning instructions. Check to make sure the UV tubes are in place. If the tubes have come out of
place, re install them. If they are broken, wearing rubber gloves clean the glass out and replace the tubes.
CAUTION, THIS OZONE GENERATOR PRODUCES DANGEROUS ULTRAVIOLET LIGHT,
DISCONNECT POWER BEFORE OPENING TO SERVICE
SPECIFICATIONS FOR OUV-550-HF Ozone Generator
Maximum output
OUV-2800-HF(T) = 2,800 mg/hr
OUV-4000-HF(T) = 4,000 mg/hr
OUV-6800-HF(T) = 6,800 mg/hr
Fan (rated cfm)
105 cfm
Filter
1 Cleanable foam filter
Cabinet material
Stainless steel chassis
Generation method
Ultra Violet Light
Weight
OUV-2800-HF (19lb) / OUV-4000-HF (20lb) / OUV-6800-HF (21lb)
Size
20” long x 9” wide x 7 5/8 height (including handle)
INTRODUCTION
This line is designed for various uses. This ozone generator can be used for many uses such
as deodorizing cars homes as well as oxidizing many organic contaminants.
WARRANTY
This ozone generator is warranted against defects in materials and workmanship for a period of four years from date
of purchase. Liability is limited to parts and labor only. Shipping is the sole responsibility the customer. OZSL is not
liable for damage caused by shipping, misuse, neglect or lack of regular maintenance.
LIABILITY
OZSL assumes no responsibility for any damage done to items from the use or miss use of any product sold or
manufactured by OZSL. It is the customers responsibility to test materials prior to use and to ensure that the
procedure and installation technique they are using is correct for the application.
HEALTH AND SAFETY
Ozone can be an irritant and a powerful oxidizing agent. As with most all products, ozone is dangerous only when
used improperly, as such it is important to follow safe usage guide lines.
*When doing a shock treatment, no people plants or pets/animals may be in the room when the unit is running.*
The room should not be reentered until all ozone has been depleted unless proper breathing respirators are used.
MAINTENANCE FREQUENCY
Under heavy duty use or severely polluted areas, The ozone generator filter should be inspected and cleaned if
necessary every 2 to 3 weeks. Inspect the UV tubes for fine dust or residue collecting on UV generator tube
surfaces. Light duty use requires cleaning every 2 to 6 months depending on the severity of pollution in the feed
air. In dirty conditions cleaning can be as often as 4-6 weeks.
DESCRIPTION OF OZONE GENERATOR
These ozone generators produce ozone by UV light, converting normal oxygen to ozone gas which is a very strong
oxidizing agent used to destroy odors and other organic contaminants.
PLACEMENT OF UNIT
This ozone generator is designed as a portable commercial deodorizing device. It uses 120VAC for North America,
and 220-240VAC for European countries etc. European models come with an IEC connector and it is up to the
customer to supply the proper cord (this can be acquired at any computer shop).
Please note the following points when placing the unit.
-Place on a flat solid surface such as a table or shelf. Do not place on rug flooring to reduce dust entering the unit
-Do not place in an area where the unit could be splashed with water, moisture or in an area that it could get
flooded with water.
-Ensure that the unit gets proper fresh air flow. Do not obstruct the incoming or outgoing air from the unit.
-If used in temperatures below freezing, ensure that condensation inside the unit does not occur.
-Set the unit in an area where it will provide the best ozone distribution.
-The use of circulation fan will greatly increase the efficiency of the treatment.