background image

3. Locate and remove the 11/32 nut from the high voltage towers, 

and remove holding clip 

(Figure 4).

 

4. Use a Phillips screwdriver to remove the plate bracket that holds the plates in the clip rings.  

There is one screw on each side (

Figure

 5). 

5. Grip generator plate just above retainer clip and gently lift plate up approx. 3/4 of the way, 

then re-grip generator plate just above retainer clip again to ensure that plates do not spread 

and fall apart upon removal  

(Figure 6)

.

 

 

 

 

 

6. Carefully separate and place the four pieces in a shallow tray 

(Figure 7)

.  Take a dry paper 

towel and rub the mica plate to remove any film deposits that might be present.  Run water on 

the stainless steel screens to remove nitric acid precipitate.  Use a cloth to thoroughly dry the 

stainless steel grids  

(Figure 7)

.

  

 

 

 

 

 

 

 

 

 

 

 

 

 

4. Once dried, mica 

plates  must  be 

inspected. 

Hold 

plate up to a light to 

ensure  no  arc  holes  have  developed

  (Figure  8)

  or  that  any  other  damage  is  present 

(Figure 

 

Figure 7

 

 

Figure 4

 

Figure 3

 

Figure 2

 

Figure 8

 

Figure 9

 

Figure 6

 

Figure 5 

Отзывы: