 GENERAL POWER TOOL SAFETY WARNINGS

 ADDITIONAL SAFETY WARNINGS FOR PUMPS

SYMBOLS

ORDERING REPLACEMENT PARTS

WARNING!

 

Read all safety warnings and all instructions. 

Failure to follow the warnings and 

instructions may result in electric shock, fire and/or serious injury. 

 

Save these instructions

1. Work area safety 

a.  

 Keep work area clean and well lit

. Cluttered or dark areas invite accidents. 

b.  

Donotoperatepumpsinexplosiveatmospheres,suchasinthepresenceofflammableliquids,

gases or dust.

 Pumps create sparks which may ignite the dust or fumes. 

c.  

 Keep children and bystanders away while operating a pump.

 Distractions can cause you to lose control.\

2. Personal safety 

a.  

 Stay alert, watch what you are doing and use common sense when operating a pump. Do not use 

apumpwhileyouaretiredorundertheinfluenceofdrugs,alcoholormedication.

 A moment of 

inattention while operating a pump may result in serious personal injury. 

b.  

 Avoid accidental starting. 

Carrying pump with your finger on the recoil starter invites accidents.

3. Pump use and care 

a.  

 Store idle pump out reach of children and other untrained persons.

 Pumps are dangerous in the hands 

of untrained users.

b.  

 Always shut off the engine, allow the engine to cool and remove spark plug before making any 

adjustments, changing accessories,or storing pumps.

 Such preventive safety measures reduce the risk 

of starting the pump accidentally. 

c.    

Maintain pumps. Check for misalignment or binding of moving parts, breakage of parts and any other 

condition that may affect the pumps operation. If damaged, have the pump repaired before use.

 Many 

accidents are caused by poorly maintained pumps. 

d.    

Use the pump, and accessories etc., in accordance with these instructions and in the manner 

intended for the particular type of pump, taking into account the working conditions and the work to 

be performed.

 Use of the pump for operations different from intended could result in a hazardous situation. 

4. Service 

a.  

Haveyourpumpservicedbyaqualifiedrepairpersonusingonlyidenticalreplacementparts.

This will 

ensure that the safety of the pump is maintained.

WARNING! 

This product is intended for pumping water in a Home Domestic application. Do 

not use it for corrosive, abrasive, explosive or dangerous liquids. Fluids other than water will 

damagethewaterpumpand/orcreateafirehazard.Failuretofollowallinstructionslisted

belowmayresultinelectricshock,fireand/orseriousinjury.

WARNING!

 This product is not suitable for use with drinking (potable) water.

This appliance is not intended for use by person (including children) with reduced physical, sensory or 

mental capabilities, or lack of experience and knowledge, unless they have been given supervision or 

instruction concerning use of the appliance by a person responsible for their safety.

Children should be supervised to ensure that they do not play with the appliance.

•  Ensure the water pump is switched off when installing.

• 

Donotinstalloroperatethewaterpumpinanexplosiveenvironmentornearflammablematerial.

•  Do not operate the water pump without liquid.

•  Do not run the water pump dry.

•   Never refuel while engine is running or hot.

 Fuel spilled on a hot engine could result in a fire or explosion.

• 

Usecautionwhenhandlingpetrol.Refuelinwell-ventilatedarea.Donotoverfillfueltankanddonot

spill fuel. Make sure tank cap is closed properly

. Petrol is extremely flammable and is explosive under 

certain conditions.

• 

Neverruntheengineinanenclosedorconfinedarea.

 Exhaust contains poisonous carbon monoxide gas; 

exposure may cause loss of consciousness and may lead to death.

• 

Donotusetopumpflammableorexplosiveliquidssuchasgasoline,fueloil,kerosene,solventsor

thinners. Pump should only be used with liquids compatible with pump component materials. 

Failure 

to follow to this warning can result in serious personal injury, death and/or property damage.

•   Pump must be located on a solid level surface.

 Pump could tip or fall causing serious injury.

•   Do not hold or suspend pump by means of a discharge pipe.

 Pipe could break or come loose.

• 

Becarefulnottotouchthemufflerwhileitishot.Toavoidsevereburnsorfirehazards,letthe

 

engine cool before transporting or storing it indoors. 

The muffler becomes very hot during operation and 

remains hot for a while after stopping the engine. Exhaust may contain chemicals that may cause cancer or 

reproductive harm.

WARNING!

 The water pump together with associated pipework operate under pressure. Do not 

disconnect water pump or pipework until internal pressure has been released. Failure to do this 

could result in personal injury and damage to property.

•  Avoid inserting hands into the inlets/outlets of the water pump while it is operating.
•  Before using the water pump, always inspect it visually. Do not use the pump if it is cracked and/or damaged.  

If the water pump is damaged, contact Ozito customer service.

•  The pump must not be used when people are in the water.
• 

Pollution of the liquid could occur due to leakage of lubricants

If no water is produced within 10 minutes, stop pump, release all pressure, remove priming plug, refill and try 

again.

WARNING!

 Hazardous pressure and risk of explosion and scalding. If pump is run continuously 

atnoflow(thatis,withdischargeshutofforwithoutpriming),watermayboilinpumpand

pipingsystem.Understeampressure,pipesmayrupture,blowofffittingorblowoutpump

ports and scald anyone near.

To prevent explosion, do the following:

A. Ensure discharge (valve, hose nozzle, etc) is open whenever pump is running.
B.  If pump fails to produce water when attempting to prime, release all pressure, drain pump and refill with cold 

water after every two attempts.

C.  When priming, monitor pump and piping temperature. If pump or piping begin to feel warm to the touch, shut 

off pump and allow system to cool. Release all pressure in the system and refill pump and piping with cold 

water.

  

V

 

    Volts 

 

 

 

Hz

 

    Hertz

  

~

 

    Alternating current 

 

W

 

    Watts

/min

      Revolutions or 

 

    reciprocation per minute

 Hp

      Horse power 

 

 

 ˚C

          Degrees Celsius   

p/hr

      Per hour   

 

  

kPa

        Pressure rating (kilopascals)        

 bar

      Pressure rating   

             

L

           Litres     

  

F

 

    Insulation class   

          

PVC

        Polyvinyl chloride     

 

 

n

o      

No load speed

Regulator compliance mark

Warning

Read instruction manual

IPX8

       Ingress protection from water

cc

Cubic centimeters

Fire

Toxic fumes

Hot surface

Содержание PTP-425

Страница 1: ...LABLE A CUSTOMER SERVICE REPRESENTATIVE WILL TAKE YOUR CALL AND ANSWER ANY QUESTIONS YOU MAY HAVE RELATING TO THE WARRANTY POLICY OR PROCEDURE OZITO Australia New Zealand Head Office 1 23 Letcon Drive...

Страница 2: ...and is capable of a maximum suction height lift of 7m WARNING AVOID POSITIONING THE INLET PIPE HIGHER THAN THE PUMP AS THIS WOULD DELAY THE ESCAPE OF AIR BUBBLES FROM THE INLET PIPE WARNING THE INPUT...

Страница 3: ...ESULT IN AN AIR LEAK WHICH CAN PREVENT THE PUMP FROM PRIMING 1 Ensure the pump is mounted to a rigid base or ground 9 5m 7m MAXIMUM DELIVERY HEIGHT WATER LEVEL WARNING ALWAYS CARRY OR LIFT THE PUMP BY...

Страница 4: ...r petrol H L H L WARNING BE SURE TO STOP THE ENGINE AND ALLOW TO COOL DOWN BEFORE REFUELLING DO NOT SMOKE WHILE REFUELLING WARNING DO NOT OVER FILL THE FUEL TANK Adding Fuel Adding Oil After the first...

Страница 5: ...by following the steps outlined in the maintenance section of this manual 2 To remove and install the spark plug refer to the maintenance section of this manual 1 Make sure the electrode is clean and...

Страница 6: ...he filter cover and screw 1 Remove the spark plug lead 3 Clean the electrode with a metal brush and remove any carbon build up or replace the spark plug Turn the drain screw anti clockwise and remove...

Страница 7: ...ter level and increase discharge line length if necessary Increase throttle Unit will not start No fuel Low quality or deteriorated old fuel Dirty muffler exhaust Choke adjusted incorrectly Air filter...

Страница 8: ...tched off when installing Do not install or operate the water pump in an explosive environment or near flammable material Do not operate the water pump without liquid Do not run the water pump dry Nev...