Air Filter Seal
Sponge
Air Filter Separator
Cover
Air Filter Service
A dirty air cleaner will restrict air flow to the carburettor. To prevent
carburettor malfunction, service the air cleaner regularly. Service more
frequently when operating the generator in extremely dirty areas.
1. Release the air filter wire
clips and revove the cover.
2. Check the air filter sponge is
intact and clean, if not rince
with water and allow to dry or
replace the filter.
Note:
It is normal for a little oil to appear under the air filter box if the
generator is running for a long period of time, or if a lot of oil is in the
engine. Wipe up the excess oil after each use and after stopping the
generator.
WARNING!
DO NOT USE PETROL OR LOW FLASH POINT
SOLVENTS FOR CLEANING. THEY ARE FLAMMABLE AND
EXPLOSIVE UNDER CERTAIN CONDITIONS.
WARNING!
NEVER RUN THE ENGINE WITHOUT THE AIR
CLEANER. RAPID ENGINE WEAR WILL RESULT FROM
CONTAMINANTS SUCH AS DUST AND DIRT BEING DRAWN
THROUGH THE CARBURETTOR, INTO THE ENGINE.
Spark Plug Servicing
Use only good quality spark plugs. To ensure proper engine operation,
the spark plug must be properly gapped and free of deposits.
1. Pull out the spark plug lead.
2. Remove the spark plug using
the spark plug wrench supplied
by turning ant-clockwise.
3. Clean the electrode with a
metal brush and remove any
carbon build-up or replace the
spark plug. Set the electrode
gap to 0.6 - 0.7mm
0.6 - 0.7mm
4. Install the spark plug carefully by hand, to avoid crossthreading.
Tighten it securely with Spark plug wrench.
5. Reinstall the spark plug lead.
Fuel Filter
A dirty fuel filter will restrict
fuel flow to the carburettor.
Replace fuel filter if it becomes
noticeably discoloured.
TRANSPORTING & STORAGE
When Transporting Generator
¥
When transporting a short distance,
it is advised that you use the
handles
¥
Do not overfill the fuel tank.
¥
Avoid a place exposed to direct
sunlight when putting the generator
on a vehicle. If the generator is left
in an enclosed vehicle for many
hours, high temperatures inside the
vehicle could cause fuel to vaporize,
resulting in a possible explosion.
¥
Do not operate the generator while it is on a vehicle. Take the
generator off the vehicle and use it in a well ventilated place.
¥
Do not drive on a rough road for an extended period with the generator
on board. If you must transport the generator on a rough road, drain
the fuel from the generator beforehand.
Storing the Generator for an Extended Period
1. Be sure the storage area is free of excessive humidity and dust.
2. Completely drain the fuel from the tank. Open the fuel valve, start
the engine and operate it in the idle position until all remaining fuel
is gone and the engine stops automatically.
3. Discharge oil as desribed in
(“Oil Change”)
section.
4. Check the fuel tap is turned off.
OFF
WARNING!
PETROL IS EXTREMELY FLAMMABLE AND
EXPLOSIVE UNDER CERTAIN CONDITIONS. DO NOT
SMOKE OR ALLOW FLAMES OR SPARKS IN THE AREA.
Содержание IGP-3300
Страница 1: ...1116 IGP 3300 INVERTER GENERATOR 3300W ASSEMBLY SAFETY WARNINGS...
Страница 7: ...Page 12...