![background image](http://html1.mh-extra.com/html/ozito/igp-3300/igp-3300_assembly-and-safety-warnings_1666410013.webp)
4. CONTROL PANEL cont.
WARNING!
SHUT OFF THE ENGINE BEFORE
PERFORMING ANY MAINTENANCE. IF THE ENGINE
MUST BE RUN, MAKE SURE THE AREA IS WELL
VENTILATED. THE EXHAUST CONTAINS POISONOUS
CARBON MONOXIDE GAS.
CAUTION!
USE AUTHORIZED PARTS OR THEIR
EQUIVALENT. THE USE OF REPLACEMENT PARTS WHICH
ARE NOT OF EQUIVALENT QUALITY MAY DAMAGE THE
GENERATOR.
MAINTENANCE
The purpose of the maintenance and adjustment schedule is to keep
the generator in the best operating condition.
Inspect or service as scheduled in the table below.
Project
Periodic
maintenance
time
(
1
)
Every use
Every
month or
20 hours
Every 3
months or
50 hours
Every 6
months or
100 hours
Every year
or 300
hours
Oil
Examination
○
Replace
○
Air filter
Examination
○
Clean
○(
2
)
Muffler Anti-Fire
Examination
○
Clean
○
Spark plug
Clean-
adjustment
Fuel sediment
bowl
Clean
Valve clearance
Examination-
adjustment
○(
3
)
Fuel and fuel
filter
Clean
○(
3
)
Fuel line
Examination
Every 2 years (If necessary, please change) (3)
○
○
Note:
(1) Log hours of operation to determine proper maintenance.
(2) Service more frequently when used in dusty areas.
(3) Servicing of this product can be arranged by contacting customer
service. Telephone: 1800 069 486.
Oil Change
Drain the oil while the engine is still warm to ensure rapid and complete
draining.
WARNING!
MAKE SURE TO TURN THE ENGINE SWITCH
AND FUEL LEVER ARE OFF BEFORE DRAINING.
1. With the T-spanner remove the
oil drain screw.
2. Tilt the generator and spill out the oil into a suitable container.
3. Refit the oil drain screw and refill with new oil, check the oil level
with the dipstick as desribed in
“Checking the Oil”
section.
Note:
Please dispose of used motor oil in a manner that is compatible
with the environment. Do not throw it in the rubbish bin or pour it on the
ground.
USB Outlet
The USB outputs power with a rating
of 2.0A at 5V. It is suitable for charging
mobile phones, MP3 players etc.
Before plugging the appliance into
the USB port, check that its rating
does not exceed 2.0A or 5W. Allow
the generator to warm up before
connecting the appliance to the USB
outlet.
Содержание IGP-3300