MAINTENANCE (cont.)
17
4. Turn the rotating mitre table (23) until the mitre
scale (27) is positioned at 0° (Fig. 29). It should
click into this angle as it is one of the preset angles.
5. Tighten the mitre table lock knob (25) by turning in
a clockwise direction.
6. Loosen the bevel lock knob (13) by turning in an
anti-clockwise direction (Fig. 30).
7. Set the cutting head (4) at 0° bevel (Fig. 31). The
blade (10) at 90° to the rotating mitre table (23).
8. Tighten the bevel lock knob (13) by turning in a
clockwise direction.
9. Place a set square (not included) on the rotating
mitre table (23) up against the flat part of the
blade (10) (Fig. 32).
NOTE:
Ensure the set square contacts the flat part of
the blade and not the teeth.
10. Rotate the blade (10) by hand and check the
blade-to-table alignment at several points.
11. The edge of the set square and the blade (10)
should be parallel.
Fig. 32
90º
Fig. 31
Fig. 30
Fig. 29