12.

 

 Battery Management System (BMS) 

 
Thanks to years of research and development your 

OzCharge

® 

Lithium battery has state of the art 

technology monitoring the battery. Internally within your battery, an active Battery Management System 
or BMS constantly monitors the individual cells for voltage, temperature, state of charge, cell balance, 
discharge loads, charge voltage and charge current. 
 
BMS Protections: 

 

 

Event 

 

Model

 

Protection Condition 

Reset Condition 

Over Discharge  
  
  

OCBL12-44 & OCBL12-55  

<10V / 50—300mS 

>10V / Cut Load 

,Auto release 

OCBL12-80, OCBL12-100, 
OCBL12-120, OCBL12-200 & 
OCBLS12-160  

<10V / 3.7-5.7S 

>10.6V / Cut Load 

,Auto release 

OCBL36-100 

<30V / 10-300ms 

>31.2V / Cut Load 

,Auto release 

Over Charge  
  
  

OCBL12-44 & OCBL12-55Ah  

>14.8V / 0.5-2S 

<14.4V 

OCBL12-80, OCBL12-100, 
OCBL12-120, OCBL12-200 & 
OCBLS12-160  

>14.88V / 0.5-1.5S 

<14.4V 

OCBL36-100 

>44.4V / 0.8-2S 

<42V / 5S 

Over Discharge 
Current  

All Models  

Please Refer to Product Label and / or 

Specific Data Sheet  

Short Circuit Current  

All Models  

Please Refer to Product Label and / or 

Specific Data Sheet 

High Discharge 
Temperature Protect  

All Models  

65°C± 

45°C± 

High Charge 
Temperature Protection 

All Models  

65°C± 

48°C± 

Active Cell Balance 
  

OCBL12-44, OCBL12-55, 
OCBL12-80,OCBL12-100, 
OCBL12-120, OCBL12-200 &  
OCBSL12-160 

 >14V                                                         

Automatic as required 

OCBL36-100 

 >42V       

Automatic as required 

 
  

13.

 

 General Specifications  

 

 

 

Nominal Voltage 

12.8V, 24V, 36V or 48V (model dependant)* 

IP Rating  

IP65 or IP67 (model dependant)* 

Parallel Connection  

4 Max** 

Series Connection  

4 Max** (12.8V Models only)  

0 for 24V, 36V and 48V models 

Case Material  

Flame Retardant ABS Plastic 

Battery Terminal Torque Setting 

M6 (4-6 Nm Torque) 
M8 (7-9 Nm Torque) 

Operating Temperature Range 

-20

o

C~+60

o

C   Relative Humidity 

85% 

Charge Temperature Range  

0

o

C – 55

o

Charge Voltage 12.8V (for OCBL12-XXX) 

14.4V ± 0.2V @ 0°C to 55°C 

Charge Voltage 24V (for OCBL24-XXX) 

28.8V ± 0.4V @ 0°C to 55°C 

Содержание OCBL12-100

Страница 1: ...tten permission of Zylux Energy Pty Ltd 08 22 v1 0 IMPORTANT PLEASE READ THIS MANUAL IN CONJUCTION WITH THE PRODUCT DATA SHEET AND MATERIAL SAFETY DATA SHEET AVAILABLE FROM OUR WEBSITE THIS MANUAL CON...

Страница 2: ...rage 8 10 Shipping 9 11 Recycling 9 12 Battery Management System BMS 10 13 General Specifications 10 14 Charging Your OzCharge Lithium Battery 11 15 Warranty 12 PLEASE ENSURE YOU CHARGE THIS BATTERY B...

Страница 3: ...battery Do not dispose of battery in household waste or incinerator Keep an appropriate and updated first aid kit within reach Avoid contact with any fluids that leak from the battery In Case of Fire...

Страница 4: ...can be joined in series or parallel Do not submerge the battery in any kind of water Do not store the battery at a voltage lower than 13 0V Do not overtighten the battery terminals See battery label...

Страница 5: ...m is 100 Cobalt Free which increases fire safety and is both environmentally and socially conscious Optional Bluetooth models so that you can interact with your battery Slimline options for those comp...

Страница 6: ...re possible Charge the battery correctly with a charger that has a dedicated Lithium setting Check that the charger will charge to the correct voltage and current refer to the Data Sheet for your batt...

Страница 7: ...ndependently to full to restore balance in the pack and extend the life of your batteries Important All batteries must be same state of charge we recommend fully charged and within 100mV of each other...

Страница 8: ...ischarge rates of less than 3 per month the battery will self discharge over time Therefore it is important for the life of your battery to keep the battery charge maintained Every 3 6 months we recom...

Страница 9: ...conscious We start this process by supplying you a product with a significantly longer life cycle than traditional lead acid batteries We consider very carefully who we partner with to manufacture ou...

Страница 10: ...44 4V 0 8 2S 42V 5S Over Discharge Current All Models Please Refer to Product Label and or Specific Data Sheet Short Circuit Current All Models Please Refer to Product Label and or Specific Data Shee...

Страница 11: ...nt or amperage of 20 to 30 or less of your battery capacity You can charge at much higher rates refer to the product label on the battery however you will reduce the cycle life of your battery at high...

Страница 12: ...2203 or email info zylux com au in Australia Warranty does not cover defects due to normal wear and tear abuse damage neglect reverse polarity connections over or under charging incorrectly charging c...

Отзывы: