background image

7 • Oz Charge manual 

 www.ozcharge.com.au

THE CHARGING PROCESS: LITHIUM

1)  Lithium Activation - Blue Charging LED Blinking

The charger sends a signal to wake up the Lithium battery management system (BMS) so it can 
detect the battery voltage and commence charging if safe to do so.

2)  Soft Start Charging - Blue Charging LED Flashing

Gently charges the battery using a reduced charge output until the battery voltages reaches 
10V.   If the battery voltage doesn’t reach 10V within 24 hours, the safety timer protection will 
stop the unit from charging and the Charging, Full and Lithium LED’s will all flash.

3)  Bulk Charging - Blue Charging LED ON

Uses the maximum charge output (1.5A) until the battery voltage reaches 14V.                                        
If the battery voltage doesn’t reach 14V within 48 hours, the safety timer protection will stop the 
unit from charging and the Charging, Full and Lithium LED’s will all flash.

4)  Absorption Charging Stage 1 - Blue Charging LED ON

Uses a constant voltage of 14V while reducing the charging output current to ensure the 
battery receives approximately 90% charge without overcharging the battery. 

5)  Absorption Charging Stage 2 - Blue Charging LED ON

Steps up the constant voltage to 14.4V while reducing the charging output current to ensure 
the battery receives a full charge without overcharging the battery. 

6)  Float Mode - Full Green LED ON

Once the battery is fully charged, the Green Full LED will come on. The charger output will stop. 
However it will continue to monitor the battery condition as it will enter Long Term Analysis 
mode.

Long Term Analysis - Full Green LED ON

During long term analysis mode, the charger will monitor the battery level and reactivate the 
charger output if the voltage drops below 12.8V to ensure the battery is always ready when you 
need it. 

STEP 5 - Disconnecting the Battery charger from Battery

• 

If the Battery is out of the vehicle:

  

(1) Switch OFF and Remove the AC Power Socket from the outlet.

      

(2) Remove the Black lead and then the Red/Orange lead.

• 

If  the battery is still in the vehicle:

  

(1) Switch OFF and Remove the AC Power Socket from the outlet.

  

(2) Remove the lead from the vehicle chassis.

  

(3) Remove the lead from the battery.

Note: 

Check electrolyte levels if possible after charging as they may need topping up with distilled 

water.  (This does not apply to Sealed Maintenance Free batteries and Lithium type batteries)

Содержание OC-PRO150L

Страница 1: ...OWNER S MANUAL Model OC PRO150L AUSTRALIAN NEW ZEALAND STANDARD AS NZS 60335 2 29 APPROVED...

Страница 2: ...has been dropped or damaged Do not attempt to use the charger if the cables or plugs are damaged If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qu...

Страница 3: ...singandpeakpulse reconditioningtorepairsulphatedbatteries Thisfeatureisfullyautomaticand dependsontheinternalimpedanceofthebattery Lead AcidModeOnly Can be left on 24 7 to ensure your battery is alway...

Страница 4: ...ited and the fault LED will come on Thispreventsthechargerfrombeing damagedifthepositiveandnegativecrocodileclipsorringterminalsaccidentlytouch eachotherwhilethechargeristurnedon ECO MODE This Oz Char...

Страница 5: ...Size L W H 140mm x 65mm x 35mm Weight 0 45kg Approvals AS NZS EMC CHARGING INSTRUCTIONS STEP 1 DETERMINE AND SELECTYOUR BATTERYTYPE BEFORE CONNECTINGTHE CHARGERTOYOUR BATTERY PLUG IN CHARGER ANDTURN A...

Страница 6: ...e Crocodileclip orringterminaltothepositive battery terminal ConnecttheBlack Crocodileclip orringterminaltothenegative battery terminal If Negatively Earthed Most Common FIRST Connect the Red Orange C...

Страница 7: ...ery voltages reaches 10V If the battery voltage doesn t reach 10V within 24 hours the safety timer protection will stop the unit from charging and the Red Fault LED will turn on 3 Bulk Charging Blue C...

Страница 8: ...ut overcharging the battery 5 Absorption Charging Stage 2 Blue Charging LED ON Steps up the constant voltage to 14 4V while reducing the charging output current to ensure the battery receives a full c...

Страница 9: ...ing ON OFF ON OFF Bad Cell Sulphated battery OFF OFF ON OFF Reverse Polarity Soft Start or Bulk Charging time out error OFF OFF ON ON Full Float mode OFF ON ON OFF Final Analysis check fail OFF Flash...

Страница 10: ...9 Oz Charge manual www ozcharge com au CHARGING CURVES...

Страница 11: ...se Check that the crocodile clips ring terminals are connected to the correct polarity Note The charger output is only present when connected to a battery The full light won t come on Red Fault LED is...

Страница 12: ...y the customer should enclose a copy of their receipt for proof of purchase It is recommended that returned products be sent by registered mail as OzCharge Australia Pty Ltd Oz Charge accepts no respo...

Отзывы: