STEP 4 - Plug the battery charger back into Mains Power (240Vac)

• 

The charger will automatically start when AC power is connected and switched on.     

Once the charger is switched on, please check the correct battery type is selected as 

per STEP 1.         

Note:

 If the Red FAULT comes on when turned on, please check your connections as it’s likely 

that the Positive and Negative Leads are reversed. Refer to Trouble Shooting Page for further 

information. 

THE CHARGING PROCESS: LEAD-ACID

1)  Automatic Rejuvenation - Blue Rejuvenation LED Blinking

If the initial qualification detected that the battery was in poor condition, the automatic 
rejuvenation process will begin automatically. During the rejuvenation process a high voltage 
equalising and 16V peak pulse reconditioning charge is used to repair the sulphated battery. 
This unique patented feature will break down and dissolve the lead-sulphate crystal build up 
on the battery plates which will extend the life of your battery. It can also balance out high 
concentrations of acid. This feature is time limited and will transit to Soft Start after 24 hours.

2)  Soft Start Charging - Blue Charging LED Flashing

Gently charges the battery using a reduced charge output until the battery voltages reaches 
10V.   If the battery voltage doesn’t reach 10V within 24 hours, the safety timer protection will 
stop the unit from charging and the Red Fault LED will turn on.

3)  Bulk Charging - Blue Charging LED ON

Uses the maximum charge output (1.5A) until the battery voltage reaches 14.4V.                                        
If the battery voltage doesn’t reach 14.4V within 48 hours, the safety timer protection will stop 
the unit from charging and the Red Fault LED will turn on.

4)  Battery Cell Check - Cell Analysis

During Bulk Stage, the charger will check and analyses the battery condition to determine 
whether the battery contains a dead/shorted cell. If this analysis fails, the Red Fault LED will 
flash.

5)  Absorption Charging - Blue Charging LED ON

Uses a constant voltage while reducing the charging output current to ensure the battery 
receives a full charge without overcharging the battery. 

6)  Sulphation Check Battery Analysis - Blue Charging LED ON

The battery analysis stage checks the condition of the battery after the charge cycle is 
completed. If the battery voltage drops too quickly during the analysis mode, this means the 
battery is probably faulty. This is indicated by the Green Full LED flashing.

7)  Float Mode - Full Green LED ON

This stage allows you to keep the charger connected 24/7 to ensure your battery is well 
maintained and kept 100% fully charged. Float mode will maintain the battery at a constant 
13.6V.  Recharge Cycle every 7 days.

Содержание OC-PRO150L

Страница 1: ...OWNER S MANUAL Model OC PRO150L AUSTRALIAN NEW ZEALAND STANDARD AS NZS 60335 2 29 APPROVED...

Страница 2: ...has been dropped or damaged Do not attempt to use the charger if the cables or plugs are damaged If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qu...

Страница 3: ...singandpeakpulse reconditioningtorepairsulphatedbatteries Thisfeatureisfullyautomaticand dependsontheinternalimpedanceofthebattery Lead AcidModeOnly Can be left on 24 7 to ensure your battery is alway...

Страница 4: ...ited and the fault LED will come on Thispreventsthechargerfrombeing damagedifthepositiveandnegativecrocodileclipsorringterminalsaccidentlytouch eachotherwhilethechargeristurnedon ECO MODE This Oz Char...

Страница 5: ...Size L W H 140mm x 65mm x 35mm Weight 0 45kg Approvals AS NZS EMC CHARGING INSTRUCTIONS STEP 1 DETERMINE AND SELECTYOUR BATTERYTYPE BEFORE CONNECTINGTHE CHARGERTOYOUR BATTERY PLUG IN CHARGER ANDTURN A...

Страница 6: ...e Crocodileclip orringterminaltothepositive battery terminal ConnecttheBlack Crocodileclip orringterminaltothenegative battery terminal If Negatively Earthed Most Common FIRST Connect the Red Orange C...

Страница 7: ...ery voltages reaches 10V If the battery voltage doesn t reach 10V within 24 hours the safety timer protection will stop the unit from charging and the Red Fault LED will turn on 3 Bulk Charging Blue C...

Страница 8: ...ut overcharging the battery 5 Absorption Charging Stage 2 Blue Charging LED ON Steps up the constant voltage to 14 4V while reducing the charging output current to ensure the battery receives a full c...

Страница 9: ...ing ON OFF ON OFF Bad Cell Sulphated battery OFF OFF ON OFF Reverse Polarity Soft Start or Bulk Charging time out error OFF OFF ON ON Full Float mode OFF ON ON OFF Final Analysis check fail OFF Flash...