background image

6 • Oz Charge manual   

www.ozcharge.com.au

THE CHARGING PROCESS:

1)  Qualification - Battery Condition Check

When the charger is first switched on it checks the battery condition to determine whether the 
battery needs reconditioning. During this qualification process it checks the internal impedance 
and initial voltage of the battery and it will determine how much charge current, if any that the 
battery will accept. 

2)  Enhanced Battery Rejuvenation - Blue Bulk LED Flashing Fast

If the initial qualification detected that the battery was in poor condition, the patented 
rejuvenation process will begin automatically. During the rejuvenation process a high voltage 
equalising and peak pulse reconditioning charge is used to repair the sulphated battery. 
This unique patented feature will break down and dissolve the lead-sulphate crystal build up 
on the battery plates which will extend the life of your battery. It can also balance out high 
concentrations of acid. The equalisation voltage will be 32V maximum. If the battery voltage 
doesn’t reach 18V within 24 hours, the Rejuvenation process will time out.

3)  Soft Start Charging - Blue Bulk LED Flashing Slow

Gently charges the battery using a reduced charge output until the battery voltages reaches 
22V. If the battery voltage doesn’t reach 22V within 6 hours, the safety timer protection will stop 
the unit from charging and the Red Fault LED and Blue Bulk LED will start flashing.

4)  Bulk Charging - Blue Bulk LED ON

 (Charge Voltage depends on battery type selection)

Uses the maximum selected charge output until the battery voltage reaches 28.2/28.8/29.4V.     
If the battery voltage doesn’t reach this within 24 hours, the safety timer protection will stop the 
unit from charging and the Red Fault LED will start flashing and the Blue Bulk LED will be ON.

5)  Absorption Charging - Green Absorption LED ON

Uses a constant voltage while reducing the charging output current to ensure the battery 
receives a full charge without overcharging the battery. 

6)  Equalisation Charging - Blue Bulk LED and Green Absorption LED both flashing 

A well proven process that carefully overcharges the battery to restore it’s full capacity. The 
Equalisation stage for CALCIUM Battery type selection is automatic. The Equalisation stage for 
AGM&WET and GEL Battery Types only occurs if the initial start voltage is below 22 Volts.

7)  Battery Analysis - Green Full LED ON

The battery analysis stage checks the condition of the battery after the charge cycle is 
completed. If the battery voltage drops too quickly during the analysis mode, this means the 
battery is probably faulty.  If the battery analysis failed, this is indicated by the Green Full LED 
flashing.

8)   Float Mode - Full Green LED ON

This stage allows you to keep the charger connected 24/7 to ensure your battery is well 
maintained and kept 100% fully charged. Float mode will maintain the battery at a constant 
27.2V. 

Содержание OC2406U

Страница 1: ...LAND STANDARD AS NZS 60335 2 29 APPROVED RED BLACK CONNECTION IN VEHICULE NEGATIVELY EARTHED RED BLACK CONNECTION IN VEHICULE POSITIVELY EARTHED 6 OWNER S MANUAL Model OC2406U AUSTRALIAN NEW ZEALAND STANDARD AS NZS 60335 2 29 APPROVED ...

Страница 2: ...er for at least 10 minutes and seek medical attention Someone should always be within range of your voice Never attempt to charge a damaged battery frozen battery or non rechargeable battery Never place the charger on the battery or battery on the charger When working with lead acid batteries remove personal metal items such as rings bracelets necklaces watches and make sure you don t short circui...

Страница 3: ... the battery is still connected in the vehicle Canbelefton24 7toensureyourbatteryisalwaysmaintainedandfullycharged The battery charger can be left unattended and left permanently connected all year round The intelligent charger will monitor the battery voltage and will maintain it at peak performance with a special pulse charge during long term maintenance Shortcircuitandreversepolarityprotection ...

Страница 4: ...polarity SHORTCIRCUITPROTECTION The charger will automatically turn off if the output leads are short circuited and the fault LED will come on Thispreventsthechargerfrombeingdamaged ifthepositiveandnegativecrocodileclipsortheoptionalringterminalsaccidentlytoucheach otherwhilethechargeristurnedon ECO MODE This Oz Charge battery charger has a built in ultra low power consumption circuit If AC power ...

Страница 5: ...C StorageTemperature 25 to 85 C Operating Humidity 90 RH Max Size L W H 214mm x 103mm x 55mm Weight 1 1kg Approvals CE UL cUL AS NZS EMC CHARGING INSTRUCTIONS STEP 1 Pre charge check electrolyte level check Check the Battery Electrolyte levels Not required on sealed maintenance free batteries If necessary remove the vent caps and add distilled water so the levels are halfway between the upper and ...

Страница 6: ...battery terminal Connect the Black Crocodile clip or optional ring terminal to the battery terminal If Positively Earthed FIRST Connect the Black Crocodile clip or optional ring terminal lead to the battery terminal and then connect the Red Crocodile clip or optional ring terminal lead to the vehicle s chassis DO NOT connect the Red lead to the carburettor or fuel lines If the battery is still in ...

Страница 7: ...the unit from charging and the Red Fault LED and Blue Bulk LED will start flashing 4 Bulk Charging Blue Bulk LED ON Charge Voltage depends on battery type selection Uses the maximum selected charge output until the battery voltage reaches 28 2 28 8 29 4V If the battery voltage doesn t reach this within 24 hours the safety timer protection will stop the unit from charging and the Red Fault LED will...

Страница 8: ...ay need topping up with distilled water This does not apply to sealed maintenance free batteries LED STATUS INDICATOR TABLE LED Status Description BatteryTypeLED s Green ON Indicates which BatteryType is selected ChargeRateLED s Green ON Indicates which Charge Rate Charge Mode is selected ChargingStatusLED s Full Green Flash ON Flashing if Analysis failed or ON if fully charged Float Maintenance m...

Страница 9: ...8 Oz Charge manual www ozcharge com au CHARGING CURVE ...

Страница 10: ...battery No charging current Fault Red LED is Flashing Battery is severely sulphated Battery has a damaged cell Overheat protection mode Check the battery condition age etc Battery may need replacement Move battery charger to a cooler environment The full float light won t come on Fault Red LED is Flashing or Full Green LED is Flashing Battery Ah capacity too large for the battery charger and it ha...

Страница 11: ...a copy of their receipt for proof of purchase It is recom mended that returned products be sent by registered mail as Zylux Distribution Pty Ltd Oz Charge accepts no responsibility liability for goods lost or damaged in transit Exclusions If upon receiving a product for repair and if testing and examining the product has disclosed that the alleged defect or malfunction in the product does not exis...