VZR.247800.001
IM
Turnstile CUBE C-03
Installation Manual
18
Table 1
– The turnstile operation mode
No. of
the
turnstile
operation
mode
Number
of short beeps after
pressing the BUT button
The turnstile operation mode
0 (simple
press)
Reboot (the mode is similar to turning on/off
of the turnstile)
1
1
Factory reset:
- pulse control mode of the turnstile
- the turnstile enters the "STOP" mode after
being switched on
- the turnstile enters the "ANTIPANIC" mode
when controlled using the ACS, after the AP
and GND contacts get connected
The turnstile is controlled by the control
panel, the status of the buttons is
transmitted to outputs ACCESS OUT (p.
5.4)
2
2
- switching between the impulse and
potential control modes of the turnstile (p.
5.3)
3
3
- the turnstile enters the mode of free
passage to the left after being switched on.
4
4
- the turnstile enters the mode of free
passage to the right after being switched on.
5
5
- activation of the "ANTIPANIC" input after
the
AP
and
GND
contacts
are
closed/opened
6
6
Disabling/enabling of the panel
7
7
Possibility to switch the relay contacts into
hold or passage counting mode, in
"ANTIPANIC" mode
8
8
- test mode for checking the turnstile
performance
5.1 Power connection
IT IS FORBIDDEN:
TO USE THE POWER SUPPLY UNITS WITH AN OUTPUT CURRENT OF
LESS THAN
1,5 А.