Oxford Instruments Andor iKon-L Скачать руководство пользователя страница 29

Version 1.4 rev 23 Apr 2019

29

IKon-L

5.2  

i

k

on

-l sy

• 

SY models (DY model code) have a Beryllium foil window as opposed to a standard window. This enables 
direct “soft” X-ray detection 

5.2.1 b

est

 p

Ractice

 g

Uidelines

• 

When not in use the window should be covered and protected.

• 

Not suitable for mounting to vacuum chamber.

• 

Due to the exposed nature of the window, care should be taken with the camera, as damage can easily occur 
through mishandling or by contamination.

• 

If due to accident or misuse the window becomes contaminated, please contact Andor immediately for advice 
on cleaning.

• 

The beryllium foil window is very brittle therefore extreme care should be taken to avoid shock damage. If the 
foil is broken there is a health risk. Please contact Andor for further information if required.

Содержание Andor iKon-L

Страница 1: ...iKon L Hardware Guide andor com Andor Technology Ltd 2019 Version 1 4 rev 23 Apr 2019 Covering models iKon L 936 iKon L SO iKon L SY iKon L HF...

Страница 2: ...OWER SUPPLY UNIT AND POWER REQUIREMENTS 17 SECTION 3 INSTALLATION 18 3 1 TRANSPORT AND STORAGE INFORMATION 18 3 2 F MOUNT 18 3 3 MOUNTING THE IKON L USING THE MOUNTING FLANGE 19 3 4 ATTACHING TO MOUNT...

Страница 3: ...N L 26 4 4 1 Adjusting the cooling fan speed 26 4 4 2 Preventing Overheating 26 SECTION 5 ADDITIONAL INFORMATION FOR SO SY AND HF MODELS 27 5 1 IKON L SO 27 5 1 1 Best Practice Guidelines 27 5 1 2 Mou...

Страница 4: ...Version 1 4 rev 23 Apr 2019 4 IKon L 6 5 FUSE REPLACEMENT 33 6 6 COOLING HOSES AND CONNECTIONS 33 SECTION 7 TROUBLESHOOTING 34 7 1 PREVENTING CONDENSATION 34...

Страница 5: ...n 1 4 rev 23 Apr 2019 5 IKon L APPENDIX A TECHNICAL SPECIFICATIONS 35 APPENDIX B MECHANICAL DRAWINGS 36 APPENDIX C DEWPOINT INFORMATION 39 APPENDIX D REFERENCE INFORMATION 40 APPENDIX E OTHER INFORMAT...

Страница 6: ...ower requirements Solis information removed this is available from Solis in built help 1 4 23 Apr 2019 Updated US and Japan addresses Updates to this Manual Changes are periodically made to the produc...

Страница 7: ...of the detachable power supply cord is required ensure replacement is of same type and rating 11 Performance of the system may be adversely affected by rapidly changing environmental conditions or op...

Страница 8: ...s that may find their way to the mains electricity supply and create a hazard Refer to the information in SECTION 3 7 for general guidelines on the correct installation and use of a liquid cooling sys...

Страница 9: ...retain the packaging materials to transport or return equipment if required If the equipment appears damaged in any way return it to sales outlet in its original packaging No responsibility for damage...

Страница 10: ...cations This manual includes a description of the main features of the iKon L installation routine operation and troubleshooting It also provides a summary of some of the technical features of the iKo...

Страница 11: ...7126 Fax 44 0 28 9031 0792 Andor Technology 300 Baker Avenue Suite 150 Concord MA 01742 USA Tel 1 860 290 9211 Fax 1 860 290 9566 Asia Pacific China Andor Technology Japan 5F IS Building 3 32 42 Higas...

Страница 12: ...ATION PROVIDED HEREIN 1 3 Copyright and Protective Notices The copyright in this document and the associated drawings are the property of Andor Technology Ltd and all rights are reserved This document...

Страница 13: ...on sheet for full model information as options vary with each model 1 Software CD Solis and SDK are ordered separately Hardware Guide in electronic format 1 Performance Booklet 1 BNC SMB Cable 2m 1 US...

Страница 14: ...below The iKon L is intended only for use with accessories recommended and supplied by Andor Please contact your local Andor representative if further information is required Description Code iKon L 9...

Страница 15: ...ltraVacTM vacuum technology has been applied to the iKon L UltraVac provides a permanent hermetically sealed enclosure for maximum QE and cooling performance over many years operation Camera Window Th...

Страница 16: ...gh impedance not 50 as an incorrect impedance match could cause errors with timing and triggering The SMB Ext Trig input is TTL level CMOS compatible and has 470 impedance I2 C The I2 C provides a con...

Страница 17: ...Input 100 240 VAC 47 63 Hz 2 2 A max Cable input is IEC connection at mains to match regional requirements Output 24 VDC 150 Watts 6 6 A max 4 pin cable see below Pin Description 1 24 VDC ve 2 24 VDC...

Страница 18: ...led from the camera 3 2 F mount The standard iKon L 936 model features a F mount for easy attachment to a wide range of compatible lenses Adapters are also available for other lens fitments refer to S...

Страница 19: ...For SO models refer to Section 5 3 4 Attaching to Mounting Posts There are three holes that can be used if required with the 1 4 UNC mounting posts with 1 spacing For further information refer to the...

Страница 20: ...at the power connectors for the iKon L camera are inserted securely The connectors are keyed to aid correct orientation The symbols on the power cable the PS 40 and the camera must be aligned correctl...

Страница 21: ...oid leaks that may find their way to the mains electricity supply and create a hazard Never use damaged split or worn hoses The coolant connectors are factory fitted and sealed they cannot be removed...

Страница 22: ...the camera head is 2 bar 30 PSI 3 9 Connecting the Liquid Cooling System An overview for connecting a liquid cooling system is outlined below please refer to the information supplied with your coolin...

Страница 23: ...ppear on the desktop on re start 7 The iKon L is now ready to be connected to a PC laptop and powered on 3 10 3 New Hardware Wizard When the iKon L camera is connected to a PC for the first time the N...

Страница 24: ...computer 2 Open the PC enclosure to gain access to the expansion slots 3 Locate a suitable PCIe slot for a USB 2 0 cards 4 If you are unsure which slot is correct please consult the PC user manual 5 R...

Страница 25: ...MAINS SOCKET AND REMOVE THE MAINS LEAD FROM THE EXTERNAL POWER SUPPLY 4 2 Power up Sequence 1 Ensure that the iKon L is powered on at the mains power supply Note there is also a power switch on the P...

Страница 26: ...or the camera temperature to stabilize before acquiring data However for optimum performance it is recommended to leave the fan setting at High 4 4 2 Preventing Overheating Care should be taken to ens...

Страница 27: ...cted and the use of a cold finger is strongly recommended Contamination Damage When not in use the sensor chamber should be covered and sealed Due to the exposed nature of the sensor extreme care shou...

Страница 28: ...side Bolts to come from this end M8 x 45 long 6 1 mm 0 24 168 1mm 6 62 24mm 0 94 No thread captive nuts 0 e g D0936N 00Z BEN Image plane of sensor Nut rotates this side Bolts to come from this end M8...

Страница 29: ...ting to vacuum chamber Due to the exposed nature of the window care should be taken with the camera as damage can easily occur through mishandling or by contamination If due to accident or misuse the...

Страница 30: ...to the camera FOP both surfaces must be free of contamination to avoid damage Dust or contamination can be removed by drop and drag optical cleaning technique For cleaning use lens tissue with a suit...

Страница 31: ...cleaning solution to the cloth then wipe the camera body with the dampened cloth Do not use abrasive or other detergents to clean the camera 6 4 Cleaning the Camera Window At some point it may become...

Страница 32: ...ing Always orient the compressed air can in an upright position before spraying A clean source of compressed air such as an air can is recommended do not use a compressor that may spray fine droplets...

Страница 33: ...the same type and rating for continued protection The characteristics of a replacement fuse are as follows Rating 5A 240 VAC Type BS 1362 size 1 6 3 25 4 mm cartridge 6 6 Cooling Hoses and Connections...

Страница 34: ...are attached If this occurs carry out the following actions 1 Switch off the system 2 Wipe the camera with a soft dry cloth NOTE It is likely there will already be condensation on the cooling block a...

Страница 35: ...ry of CAT II means that the equipment is designed to cope with transient voltages above the rated supply that would be experienced by any product connected to a mains socket in a building Rated Pollut...

Страница 36: ...Version 1 4 rev 23 Apr 2019 36 IKon L APPENDIX B MECHANICAL DRAWINGS iKon L 936...

Страница 37: ...Version 1 4 rev 23 Apr 2019 37 IKon L iKon L HF...

Страница 38: ...Version 1 4 rev 23 Apr 2019 38 IKon L iKon L SO For attachment options refer to section 5 1 2 iKon L SY...

Страница 39: ...rst signs that condensation is forming will be on the coolant connections entering and exiting the camera Use of coolant at or below the dewpoint can result in permanent damage to the camera head due...

Страница 40: ...re information about our UltraVac technology please visit our website and view the technical article on UltraVac Shutter and Triggering Information 1 The documentation supplied by the shutter manufact...

Страница 41: ...warranty conditions will have been made available during the ordering process The current version may be viewed at www andor com pdfs literature Andor_Standard_Warranty pdf Waste Electronic and Electr...

Страница 42: ..._____________________________________________________ ___________________________________________________________________ ___________________________________________________________________ __________...

Страница 43: ...Version 1 4 rev 23 Apr 2019 43 IKon L...

Отзывы: