CONVERTING TO LP/PROPANE GAS AT 

ALTITUDES BETWEEN ZERO & 10,000 FT.

Converting single stage valves to LP/Propane requires the 

replacement of the burner orifices and the spring found under 

the cap screw in the pressure regulator. Converting 2 - stage 

valves to LP/Propane requires the replacement of the burner 

orifices and the stem/spring assembly in the pressure regulator.
Table 2 (page 3), provides the manifold pressure for altitudes 

above 2,000 feet.

 WARNING:

Shut off the gas supply at the manual gas shutoff 

valve, before disconnecting the electrical power. 

A fire or explosion may result causing property 

damage, personal injury or loss of life. Failure to 

follow the safety warnings exactly could result in 

serious injury, death or property damage.

 WARNING:

To avoid electric shock, personal injury, or death, 

turn off the electric power at the disconnect or the 

main service panel before making any electrical 

connections.

 WARNING:

The reduction of input rating necessary for high 

altitude installation may only be accomplished with 

factory supplied orifices. Do not attempt to drill out 

orifices in the field. Improperly drilled orifices may 

cause fire, explosion, carbon monoxide poisoning, 

personal injury or death.

Before You Convert the Gas Valve

1. Turn the thermostat OFF or to its lowest temperature setting.

2. Verify the gas supply is shut OFF.

3. Verify the electrical power to the appliance is turned OFF.

Removing The Burner Orifices

1. Set the thermostat to the OFF position, or its lowest temperature 

setting.

2. Shut OFF the gas supply at the manual shutoff valve located 

outside of the appliance.

3. Turn off all electrical power to the appliance.

4. Remove the door from the burner compartment.

5. Move the gas valve ON/OFF switch to the OFF position as 

shown in Figure 1. For VR8205Q2381 gas valves, turn the 

knob to the OFF position.

6. Remove the wires from the terminals of the gas valve.

7. Remove the supply gas piping from the gas valve inlet.

8. Carefully remove four screws securing the gas manifold 

assembly to the burner assembly.

9. Set the screws aside and remove the gas manifold assembly 

from the appliance.

10. Carefully remove the burner orifices from the gas manifold 

assembly.

11. Read the rating plate affixed to the appliance to determine 

its rated input (Btu/hr) and the size of the factory installed 

orifices.

IMPORTANT NOTE:

Before installing an orifice, check the side or face of the orifice 

for the drill number to ensure that it is the appropriate size.

12. Install the appropriate LP/Propane gas burner orifices into 

the gas manifold assembly.

 NOTE: 

To prevent cross threading, hand tighten the orifices 

into the gas manifold assembly until snug, then tighten with a 

wrench.

 WARNING:

Do not use Teflon tape or pipe joint compound 

on the orifice threads. The hole in the orifice may 

become blocked and cause fire, explosion, property 

damage, carbon monoxide poisoning, personal 

injury, or death.

13. Reinstall the gas manifold assembly to the burner assembly 

with the 4 screws, that were removed earlier. 

NOTE:

 It is 

important that the center of the orifices are aligned with the 

center of the burners. It is recommended to fire the unit and 

check alignment of the flame after converting to LP.

14. Reconnect the gas piping to the gas valve inlet.

15. Reconnect the wires to the gas valve terminals.

Single Stage Honeywell Valves

Models: VR8205S2890 or VR8215S1289

IMPORTANT NOTE:

When converting to LP/Propane gas from natural gas, the 

black spring in the gas valve must be replaced by the red 

spring in the kit.

1. Remove the cap screw from the gas valve as shown in Figure 

2.

2. Remove and discard the plastic pressure regulator adjustment 

screw from the gas valve. See Figure 3.

3. Remove the black colored spring from the gas valve.

4. Install the red spring from the conversion kit.

5. Install the new adjusting screw from the kit.

6. Check and adjust the regulator setting. See Gas Pressure 

Adjustment Section (page 5).

7. Reinstall the cap screw.

8. Affix the label from the conversion kit to the gas valve.

Figure 1. Typical Burner & Manifold Assembly

Terminals

Orifices

ON/OFF

Switch

Gas Valve

Gas Valve

Inlet

Manifold

Assembly

Screws (x4)

Burner

Assembly

Burners

Содержание G7 Series

Страница 1: ... furnace was produced before January 2010 the NOX baffles must be removed from the furnace before conversion WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury or property damage Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any ...

Страница 2: ...rews securing the gas manifold assembly to the burner assembly 9 Set the screws aside and remove the gas manifold assembly from the appliance 10 Carefully remove the burner orifices from the gas manifold assembly 11 Read the rating plate affixed to the appliance to determine its rated input Btu hr and the size of the factory installed orifices IMPORTANT NOTE Beforeinstallinganorifice checkthesideo...

Страница 3: ...56 10 0 56 9 0 56 8 5 57 10 0 57 9 0 57 8 5 108 000 56 10 0 56 9 0 56 8 5 57 10 0 57 9 0 57 8 5 118 000 55 10 0 55 9 0 55 8 5 56 10 0 56 9 0 56 8 5 120 000 55 10 0 55 9 0 55 8 5 56 10 0 56 9 0 56 8 5 G7TA GC2TA G7TK GC2TK 60 000 55 10 0 55 9 0 55 8 5 56 10 0 56 9 0 56 8 5 80 000 55 10 0 55 9 0 55 8 5 56 10 0 56 9 0 56 8 5 100 000 55 10 0 55 9 0 55 8 5 56 10 0 56 9 0 56 8 5 120 000 55 10 0 55 9 0 5...

Страница 4: ...hten the plug first to prevent cross threading Tighten with 3 16 Allen wrench Lighting Adjustment of the Appliance WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury or property damage Never test for gas leaks with an open flame Use a commercially available soap solution made specifically for the detection of leaks to check all connections Afi...

Страница 5: ... Manometer Magnehelic Meter etc to the outlet end of the gas valve as follows 1 Turn off all electrical power to the appliance 2 Shut OFF the gas supply at the manual shutoff valve located outside of the appliance 3 Using a 3 16 Allen wrench remove the manifold pressure tap plug located on the outlet side of the gas valve See Figure 6 page 5 4 Install an 1 8 NPT pipe thread fitting that is compati...

Страница 6: ...1021834R G7SD 038D 23EB1 1 00 1018532R 0 20 1021836R G7SD 038D 24B1 1 00 1018532R 0 20 1021836R G7SD 054D 23EB1 0 80 632495R 0 50 632492R G7SD 054D 24B1 0 80 632495R 0 50 632492R G7SD 072D 35C1 0 80 632495R 0 50 632492R G7SD 072D 35C2 0 80 632495R 0 50 632492R G7SD 072D 35EC1 0 80 632495R 0 50 632492R G7SD 090D 35C1 0 80 632495R 0 60 632493R G7SD 090D 35EC1 0 80 632495R 0 60 632493R G7SD 108D 35ED...

Страница 7: ... G7TE 080D 35C1 0 35 0 75 1021821R 0 50 0 80 1021831R G7TE 080D VC1 0 35 0 75 1021821R 0 50 0 80 1021831R G7TE 100D 35C1 0 40 0 75 1021822R 0 50 0 80 1021831R G7TE 100D VC1 0 40 0 75 1021822R 0 50 0 80 1021831R G7TE 115D 45D1 0 30 0 75 1021823R 0 70 1 50 1021832R G7TE 115D VD1 0 30 0 75 1021823R 0 70 1 50 1021832R G7TK 060C 23A1 0 20 0 60 1021814R NA NA NA G7TK 060C VA1 0 20 0 60 1021814R NA NA NA...