User’s Manual of
OWON
Colour Digital Storage Oscilloscope
Persist
When the
Persist
function is used, the persistence display effect of the picture tube
oscilloscope can be simulated: the reserved original data is displayed in fade color and
the new data is in bright color. With the
F2
menu selection button, different
persistence time can be chosen:
1sec
,
2sec, 5sec, Infinite
and
Closed.
When the
“
Infinite
” option is set for
Persist
time
,
the measuring points will be stored till the
controlling value is changed (see Fig. 40).
Fig. 40
Infinite Persistence Display
XY Format
This format is only applicable to Channel 1 and Channel 2. After the XY display
format is selected, Channel 1 is displayed in the horizontal axis and Channel 2 in the
vertical axis; the oscilloscope is set in the untriggered sample mode: the data are
displayed as bright spots and the sampling rate is 1MS/s and can not be changed.
The operations of all control knobs are as follows:
The
Vertical VOLTS/DIV
and the
Vertical POSITION
knobs of Channel 1are
used to set the horizontal scale and position.
The
Vertical VOLTS/DIV
and the
Vertical POSITION
knobs
of Channel 2
are used to set the vertical scale and position continuously.
51