background image

NOTICE TO NEW USERS:

All personnel testing optical fibers should be adequately trained in the field of fiber optics before using any fiber optic 
test equipment.

If the user is not completely familiar with testing fiber optics, they should seek professional training.  Such training can 
be acquired from a variety of sources, such as local hands-on training classes.  

Valuable information about fiber optic testing can also be gathered from reading printed literature carefully or by 
thoroughly reading supplied operations manuals.

Fiber optic testers vary from other types of test equipment due to issues such as:

1) standards-based testing
2) proper fiber optic test procedures (FOTPs)
3) "zeroing" or referencing of power levels
4) determining the correct link budget to pass or fail by

Complete understanding of each of these issues is critical for performing proper fiber optic tests.

GETTING STARTED

Thank you for your purchase of this OWL certification test kit. Included in this kit is a Micro OWL 2 optical power meter 
and a WaveSource multimode fiber optic light source.  This quick reference guide will assist you in setting up your test 
kit for a standards-based certification test. 

BEFORE YOU TEST

Prior to performing a certification test, there are a few things you need to know about your link:

?

Fiber Type

?

Fiber Length

?

Number of Connections (i.e. patch panels)

?

Number of Splices

?

Fiber Cabling Standard

?

Connector Type

It is also important to understand the definition of a fiber optic link as it pertains to the Micro OWL 2:

A link is a group of fibers that have the same characteristics, and follow the same pathway from one end to 
the other.

Also, ensure that your patch cable connectors match the patch panel ports on the link under test.

Содержание Micro OWL 2 Series

Страница 1: ...73 0643 Internet OWL INC COM Revision 1 1 26009 Micro OWL 2 Series Test Kits Certification Testing Quick Reference Guide For part numbers KIT M2 WSSDst KIT M2 WSSDsc KIT M2 WSSDfc Optical Wavelength Laboratories e C s i h o W i c e e h i T n O s p e i t r i c o a t l a r F o i b b e a r L T h e t s g t n E e l q e u v i p a m W e l n a t c i t p O OWL ...

Страница 2: ...or fail by Complete understanding of each of these issues is critical for performing proper fiber optic tests GETTING STARTED Thank you for your purchase of this OWL certification test kit Included in this kit is a Micro OWL 2 optical power meter and a WaveSource multimode fiber optic light source This quick reference guide will assist you in setting up your test kit for a standards based certific...

Страница 3: ... should read approximately 10 00 dBm If the reading is below 12 00 dBm the patch cable should be replaced STEP 8 Once proper operation has been verified remove the first patch cable from both units and set it aside STEP 9 Connect the second singlemode patch cable between the Micro OWL 2 and the WaveSource as shown in Figure 2 STEP 10 The Micro OWL 2 should read approximately 10 00 dBm If the readi...

Страница 4: ...rtification reports XXXXXXXXXXXXXXXXXXXXX X X XXXXXX 1 LINK WIZARD X X XXXXXXXX 2 MAIN MENU XXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXX XXXXX X XXXXXX START MENU XXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXX XX x x xXxxxxx Fiber Link 2 x XX XXXXXXXX NEXT SELECT XX x x xXxxxxx Fiber Link 3 XX x x xxXxxxx Fiber Link 4 XXXX X XXXXX STORED LINKS _____________________ XX x x Xxxxxxx...

Страница 5: ...o wavelengths press the 1 button to set the Micro OWL 2 into AUTO mode then press and hold the 8 AUTO button on the WaveSource You will begin to see the WaveSource indicator LED alternate between and STEP 31 Disconnect the mandrel wrapped patch cable from the Micro OWL 2 and take the units to opposite ends of the link STEP 32 Connect the units to the first fiber to test as shown in Figure 3 Your r...

Страница 6: ...e first fiber in the link you may be prompted to enter a new label STEP 34 Press F3 to save the data point STEP 35 Disconnect the patch cables from the patch panels and move them to the next port in the patch panel then repeat steps 33 through 35 until all fibers in the link have been tested ...

Отзывы: