PART 3a - TAKE READINGS (1310nm), cont.
PART 3b - TAKE READINGS (1550nm)
Record the reading for the current fiber under test.
Disconnect the patch cables from both ends of the patch panel and move to the next port on the patch panel.
Repeat
and
for each fiber in the cable under test until all fibers have been tested at 1310nm.
For testing 1550nm, again connect to the first fiber under test, except this time use the patch cable connected to the
1550nm port (Figure 5).
Press
several times until the ZOOM 2 is set to 1550nm.
Record the reading for the current fiber under test.
Disconnect the patch cables from both ends of the patch panel and move to the next port on the patch panel.
Repeat
and
for each fiber in the cable under test until all fibers have been tested at 1550nm.
(end of procedure)
QUICK REFERENCE GUIDES
Optical Power Meter:
ZOOM 2
Fiber Optic Light Source: LASER OWL Series Singlemode Sources
PAGE 4 OF 4
FIGURE 5
Take Readings
(1550nm)
1 2 3 4 5 6 7 8 9 10 11 12
1 2 3 4 5 6 7 8 9 10 11 12
dB
2.00
-
1550
nm
SC connectors shown here;
connector style may vary
LIGHT SOURCE
CONNECTOR PORTS
Do NOT insert APC connector
into either light source port