background image

PART 3a - TAKE READINGS (1310nm), cont.

PART 3b - TAKE READINGS (1550nm)

Record the reading for the current fiber under test.

Disconnect the patch cables from both ends of the patch panel and move to the next port on the patch panel.

Repeat  

  and  

  for each fiber in the cable under test until all fibers have been tested at 1310nm.

For testing 1550nm, again connect to the first fiber under test, except this time use the patch cable connected to the 
1550nm port (Figure 5).

Press  

   several times until the ZOOM 2 is set to 1550nm.

Record the reading for the current fiber under test.

Disconnect the patch cables from both ends of the patch panel and move to the next port on the patch panel.

Repeat  

   and  

  for each fiber in the cable under test until all fibers have been tested at 1550nm.

(end of procedure)

QUICK REFERENCE GUIDES

Optical Power Meter:

ZOOM 2

Fiber Optic Light Source: LASER OWL Series Singlemode Sources

PAGE 4 OF 4

FIGURE 5

Take Readings

(1550nm)

1 2 3 4 5 6 7 8 9 10 11 12

1 2 3 4 5 6 7 8 9 10 11 12

dB

2.00

-

1550

nm

SC connectors shown here;
connector style may vary

 

 LIGHT SOURCE

CONNECTOR PORTS

Do NOT insert APC connector
into either light source port 

Содержание KIT-Z2-L2 Series

Страница 1: ...3 West US Hwy 12 Whitewater WI 53190 Phone 262 473 0643 Internet OWL INC COM Revision 1 4 July 19 2011 Optical Wavelength Laboratories OWL ZOOM 2 Series Test Kits Optical Loss Testing Quick Reference Guide For part numbers KIT Z2 L2xx KIT Z2 L213xx KIT Z2 L215xx KIT Z2 D2xx L2xx KIT Z2 D285xx L213xx ...

Страница 2: ...linkbudgettopassorfailby Completeunderstandingofeachoftheseissuesiscriticalforperformingproperfiberoptictests GETTINGSTARTED Thank you for your purchase of this OWL certification test kit Included in this kit is a ZOOM 2 optical power meter and a Laser OWL singlemode fiber optic laser source This quick reference guide will assist you in settingupyourtestkitforastandards basedcertificationtest BEFO...

Страница 3: ...ringthisprocedure Theseportsmayvarydependinguponthemodelofequipment REQUIREDACCESSORIES PART1 VERIFYPROPEROPERATIONOFTHEEQUIPMENT ConnectthepowermeterandlightsourcetogetherwiththefirstpatchcableasshowninFigure2 Press topowerontheLaserOWLsinglemodelasersource The1310nmportpowersonfirstbydefault Press topowerontheZOOM2opticalpowermeter Press severaltimesontheZOOM2untilthewavelengthissetto1310nm 1 QU...

Страница 4: ...ZOOM 2 should show approximately 10 00 dBm If the reading is below 12 00 dBm the patch cable should be replaced Onceproperoperationhasbeenverified continueontothenextstep PART2a SETREFERENCE 1310nm Settingareferenceiscommonlyreferredtoas zeroing With the power meter and light source still connected as shown in Figure 2 press and hold button on the ZOOM 2 to setthereferencefor1310nm The ZOOM 2 disp...

Страница 5: ...ecttheZOOM2andLaserOWLtothelinkundertestasshowninFigure4below Press severaltimesuntiltheZOOM2issetto1310nm UNITS ZERO 3 QUICK REFERENCE GUIDES Optical Power Meter ZOOM 2 Fiber Optic Light Source LASER OWL Series Singlemode Sources PAGE 3 OF 4 FIGURE 3 Set Optical Reference 1550nm Leave singlemode patch cable attached to 1310nm port SC connectors shown here connector style may vary LIGHT SOURCE CON...

Страница 6: ...ltimesuntiltheZOOM2issetto1550nm Recordthereadingforthecurrentfiberundertest Disconnectthepatchcablesfrombothendsofthepatchpanelandmovetothenextportonthepatchpanel Repeat and foreachfiberinthecableundertestuntilallfibershavebeentestedat1550nm end of procedure QUICK REFERENCE GUIDES Optical Power Meter ZOOM 2 Fiber Optic Light Source LASER OWL Series Singlemode Sources PAGE 4 OF 4 FIGURE 5 Take Rea...