HINTS, TIPS & TROUBLESHOOTING
Cost of Electricity
:- Price per kWh of electricity as shown on your electricity bill.
Tiered Cost of Electricity
:- Where the first number of kWh are at one value and everything else used is another. We recommend that you
enter an average value, calculated from your billed kWh usage (monthly/quarterly) and assuming that quarterly usage is 900kWh then Total
cost of kWh would be 210kWh @ 20.90p & 690kWh at 10.00p equalling £112-89. The average value would be £112-89 divided by 900kWh
giving 12.54p.
Multiple Timed Tariffs (ie Economy 7)
:- are not supported with OWL Micro. We recommend that you enter an average value, calculated from
your billed kWh usage (monthly/quarterly) and assuming that quarterly usage is 900kWh for day rate and 1500kWh for night rate, then Total
cost of kWh would be 900kWh @ 10.90p & 1500kWh at 4.70p equalling £168.60. The average value would be £168.60 divided by 2400kWh
giving 7.03p.
Cable Size-
The sensor is suitable to connect over a cable up to 10mm in diameter including the insulation. It is ok for the sensor to be loose
over the cable.
Display is blank
:- Ensure that the batteries are inserted the correct way around and that the batteries are not exhausted. If the batteries are
exhausted replace with new batteries. If the display does not return then contact [email protected].
Four dashes (----) flashing on the upper part of the Display
:- The Display is in a search mode looking for a Transmitter to synchronise with.
Four dashes (----) fixed on the upper part of the Display
:- The Display and Transmitter have not synchronised. Repeat the “Synchronising
the Display and Transmitter” process in the manual.
0.00 Reading on the Display
:- The sensor is not able to measure the electricity flow through the Twin/Three Core cables so will return a reading
of 0.00 if the sensor is connected over the cable of an appliance.
0.00 Reading on the Display
: Possible that the Sensor has a damaged Ferrite Core. To check to see if the sensor is damaged, you will need
to unclip the sensor from the cable and inspect the Ferrite Core (U-Shaped Black Material) in the sensor lid is still in one piece and that the
corresponding faces in the sensor body are in position. If this is damaged then contact [email protected].
Lower reading than expected
:- If the cable is a very tight fit for the sensor then it is likely the sensor is unable to be closed properly as in the
2 halves of ferrite core within the sensor do not make a flush contact then the reading will be lower than measured.