background image

4

US

 

 FEATURES & FUNCTIONS

Remote Monitor Features 

CENT-A-METER

TM

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

 SET

MODE

ADJUST

                                           

"AA"  UM3  1.5V

"AA"  UM3  1.5V

"AA"  UM3  1.5V

PART NO. CM119

MADE IN CHINA

SEARCH

RESET

17

18

20

21

19

                            

                                                                   

1.  Indicates which Display Mode the Monitor is in:  
 

COST / ENERGY / GREENHOUSE GAS

2.  Indicates Monitor is in 

SET

 mode

3.  Currency Units for Cost Display Mode
4.  Clock /Date Display (Toggles ~10secs) 
5.  Room Temperature Display
6.   Indicates when Peak Time Tariff  is in operation
7.   Indicates which Tariff is in use (up to 4)
8.   Real Time Data Display
9.   Measurement units for Display Modes
10.  Acummulative/Historical Data Display 

11.  Indicates Cost Alarm is 

ON

12. Channel indicator
13. Battery low indicator: Display (Monitor) / Remote  
 

(Sender Box)

14. 

MODE

 key

15. 

ADJUST

 key

16. 

SET

 key

17. Wall mount hole
18. 

SEARCH 

key: search for transmitter

19. 

AC / DC

 power adapter socket.(Power pack is optional)

20. 

RESET

 Key

21. Battery compartment

Remote Monitor Key Press Functions

KEY (S)

ACTION

FUNCTION

MODE

Press

Changes the Display Mode in View

COST

   

ENERGY

   

GREENHOUSE GAS

ADJUST

Press

Scrolls the Accumulative Display through various 

Historical Data values

TOTAL

   

THIS/LAST 

(

DAY WEEK MONTH

 

QUARTER YEAR

)  

SET

Press and Hold until Tone Emits

Enters the 

SET

 Mode enabling customisation of 

settings

MODE

Press and Hold until Tone Emits

Enables/Disables the Alarm Function

ADJUST

Press and Hold until Tone Emits

Changes the Units of Measure

Kg

-

Tonne

-

°C

   

lb

-

Ton

-

°F

   

Kg

-

Kg

-

°C

   

lb

-

lb

-

°F

RESET

Press

Clears 

TOTAL

 Accumulated historical Data only from 

memory generated since last reset  or first use

RESET & 

SET

Press and Hold Keys 

Simultaneously. 

Release 

RESET

 a Tone Emits. 

Release 

SET

 upon second Tone

Full Reset.

Clears Memory of all historical data and returns 

Monitor back to Factory Settings

SEARCH

Press and Hold until  Tone Emits

Places Remote Monitor into Search Mode to locate 

and link to a Sender Box

Sender Box Features

1

2

3

c he c k

     

4

5

6

PART NO. CMR119  

MADE IN CHINA

"AA"  UM3  1.5V

"AA"  UM3  1.5V

"AA"  UM3  1.5V

1  2  3

CHANNEL

1.  Flashes to indicate data transmitted from Sender Box
2.  

CHECK 

key:- Forces transmission every 2 seconds  

 

(for 30 Seconds)

3.   Sensor Cable Sockets (x3) 
4.  

RESET 

key:- Resets the Sender Box and clears  

 

all data held in memory

5.  

CHANNEL 

switch (1,2,3)

6.   Battery Compartment

Содержание CM119

Страница 1: ......

Страница 2: ...in use or rather being used needlessly UK consumers can actually save up to 25 of their electricity usage a saving that translates directly to reducing their monthly bills and households harmful carbon emissions CEO 2 Save Energy plc TABLE OF CONTENTS INTRODUCTION 1 TABLE OF CONTENTS 1 GENERAL SAFETY CARE GUIDELINES 2 HOW THE WORKS 3 Overview 3 Household Power Cables And Phase 3 Greenhouse Gas 3 D...

Страница 3: ...ers curtains etc Do not tamper with the units internal components This invalidates the warranty Do not attempt to repair the product yourself Contact the retailer or our customer service department if it requires servicing Take care when handling all battery types Batteries can cause injuries burns or damage to property if they come into contact with conducting materials heat corrosive materials o...

Страница 4: ...as Fossil fuel power stations emit gases such as carbon dioxide when producing electricity This causes an atmospheric imbalance which in turn has been linked to global warming global temperature rise Every power station has a slightly different ratio of emissions to electricity production depending on the type of fuel used to generate electricity Sustainable energy sources such as hydro solar and ...

Страница 5: ...OST ENERGY GREENHOUSE GAS ADJUST Press Scrolls the Accumulative Display through various Historical Data values TOTAL THIS LAST DAY WEEK MONTH QUARTER YEAR SET Press and Hold until Tone Emits Enters the SET Mode enabling customisation of settings MODE Press and Hold until Tone Emits Enables Disables the Alarm Function ADJUST Press and Hold until Tone Emits Changes the Units of Measure Kg Tonne C lb...

Страница 6: ... select Country CNTY menu to select generic country settings Settings Voltage Currency Units GHG Factor Generic Tariff Values Customising the Setup 2 From the OTHER menu select Currency CURR menu to select currency symbol Customising the Setup 3 From the OTHER menu select Voltage VOLT menu to select voltage setting Customising the Setup 4 From the OTHER menu select Units UNIT menu to select Metric...

Страница 7: ...o change wireless channel of operation The Sender Box will need to be changed to the same channel using the CHANNEL switch shown in Sender Box features Customising the Setup 7 From the OTHER menu select GHG Factor GHG menu to set Utility Related Factor for calculating the kWH of Energy into LB of GHG emissions Exiting Menus To Exit OTHER menu select END To Exit SET mode select END ...

Страница 8: ...nder Box within range Remove Sensor cable from Sender Box Remote Monitor should show 00 00 1 Establish communications link with Sender Box following full reset Refer to Quick Start Guide 2 If connected to sender unit check the set up of device Refer to Quick Start Guide Flashing displayed on the monitor Automatic search to find Sender Unit underway Allow search to run to completion Day Month in cal...

Страница 9: ...R6 UM 3 1 5V batteries Operating Temperature 5 C 45 C 41 F 113 F at 85 relative humidity Storage Temperature 5 C 60 C 23 F 140 F at 85 relative humidity Factory Default Setting Country Setting US Voltage 120 Units Imperial LB F Currency cents Power Units KW Energy Units KWH GHG Units LB hr Accumulative GHG Units Ton Temperature Units F GHG Conversion 1 27LB CO2 1KW hr Clock 12 hr Date mmdd Tariff ...

Страница 10: ... reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or a...

Страница 11: ... sent with the proof of purchase and product to the following address Customer Services Curo Energy 10322 Pine Forest Road Houston TX 77042 NOTE A record of the Return Reference Number should be kept and used in all correspondence relating to the return No returns will be accepted without a Returns Reference Number being allocated All returns must be by recorded delivery Product Name Product Model...

Страница 12: ......

Отзывы: