background image

1

US

INTRODUCTION

  

Thank you for selecting the 

 Wireless Energy Monitor. 

Keeping an eye on your electrical usage has never been easier with the new  

 Wireless 

Energy Monitor.  This revelatory device, which aims to help in the fi ght against climate change, 
is  set  to  show  millions  of  people  just  how  much  electricity  we  waste  in  our  homes,  whilst 
highlighting the money we can all save as a result.

 monitors the home’s electricity supply and for the fi rst time provides real-time monetary 

information  about  the  household’s  energy  usage.  When  lights  and  appliances  are  turned 
on, 

 easy-to-read LCD monitor reveals exactly how much electricity is being used, how 

the cost of electricity per hour changes, and how much harmful CO2 emissions the home is 
producing.  

By  simply  turning  off  appliances  when  not  in  use,  or  rather  being  used  needlessly,  UK 
consumers can actually save up to 25% of their electricity usage - a saving that translates 
directly to reducing their monthly bills and households’ harmful carbon emissions

CEO

2 Save Energy plc

TABLE OF CONTENTS

INTRODUCTION ....................................................................................................................................................... 1
TABLE OF CONTENTS ............................................................................................................................................ 1
GENERAL SAFETY & CARE GUIDELINES ............................................................................................................ 2
HOW THE 

 WORKS ........................................................................................................................................ 3

Overview .......................................................................................................................................................... 3
Household Power Cables And Phase .............................................................................................................. 3
Greenhouse Gas .............................................................................................................................................. 3
Definitions ........................................................................................................................................................ 3

 FEATURES & FUNCTIONS ........................................................................................................................... 4

Remote Monitor Features  ............................................................................................................................... 4
Remote Monitor Key Press Functions ............................................................................................................. 4
Sender Box Features  ...................................................................................................................................... 4

 ADVANCED SETTINGS ................................................................................................................................. 5

WHAT TO DO IF?  .................................................................................................................................................... 7

 SPECIFICATIONS .......................................................................................................................................... 8

 Factory Default Setting .......................................................................................................................... 8

COMPLIANCE .......................................................................................................................................................... 9

Declaration of Conformity ................................................................................................................................ 9

WARRANTY  ............................................................................................................................................................ 9

Limited One Year Warranty .............................................................................................................................. 9
Warranty Conditions ........................................................................................................................................ 9

DISTRIBUTOR DETAILS ......................................................................................................................................... 9
RETURNS ............................................................................................................................................................... 10

Process .......................................................................................................................................................... 10
Customer Services ......................................................................................................................................... 10

 NOTE 

 Please keep this Manual and Quick Start Guide handy as you use your 

 Wireless Energy Monitor. 

They contain practical systematic instructions, technical specifi cations, and safety precaution warnings you should 
know about.

Содержание CM119

Страница 1: ......

Страница 2: ...in use or rather being used needlessly UK consumers can actually save up to 25 of their electricity usage a saving that translates directly to reducing their monthly bills and households harmful carbon emissions CEO 2 Save Energy plc TABLE OF CONTENTS INTRODUCTION 1 TABLE OF CONTENTS 1 GENERAL SAFETY CARE GUIDELINES 2 HOW THE WORKS 3 Overview 3 Household Power Cables And Phase 3 Greenhouse Gas 3 D...

Страница 3: ...ers curtains etc Do not tamper with the units internal components This invalidates the warranty Do not attempt to repair the product yourself Contact the retailer or our customer service department if it requires servicing Take care when handling all battery types Batteries can cause injuries burns or damage to property if they come into contact with conducting materials heat corrosive materials o...

Страница 4: ...as Fossil fuel power stations emit gases such as carbon dioxide when producing electricity This causes an atmospheric imbalance which in turn has been linked to global warming global temperature rise Every power station has a slightly different ratio of emissions to electricity production depending on the type of fuel used to generate electricity Sustainable energy sources such as hydro solar and ...

Страница 5: ...OST ENERGY GREENHOUSE GAS ADJUST Press Scrolls the Accumulative Display through various Historical Data values TOTAL THIS LAST DAY WEEK MONTH QUARTER YEAR SET Press and Hold until Tone Emits Enters the SET Mode enabling customisation of settings MODE Press and Hold until Tone Emits Enables Disables the Alarm Function ADJUST Press and Hold until Tone Emits Changes the Units of Measure Kg Tonne C lb...

Страница 6: ... select Country CNTY menu to select generic country settings Settings Voltage Currency Units GHG Factor Generic Tariff Values Customising the Setup 2 From the OTHER menu select Currency CURR menu to select currency symbol Customising the Setup 3 From the OTHER menu select Voltage VOLT menu to select voltage setting Customising the Setup 4 From the OTHER menu select Units UNIT menu to select Metric...

Страница 7: ...o change wireless channel of operation The Sender Box will need to be changed to the same channel using the CHANNEL switch shown in Sender Box features Customising the Setup 7 From the OTHER menu select GHG Factor GHG menu to set Utility Related Factor for calculating the kWH of Energy into LB of GHG emissions Exiting Menus To Exit OTHER menu select END To Exit SET mode select END ...

Страница 8: ...nder Box within range Remove Sensor cable from Sender Box Remote Monitor should show 00 00 1 Establish communications link with Sender Box following full reset Refer to Quick Start Guide 2 If connected to sender unit check the set up of device Refer to Quick Start Guide Flashing displayed on the monitor Automatic search to find Sender Unit underway Allow search to run to completion Day Month in cal...

Страница 9: ...R6 UM 3 1 5V batteries Operating Temperature 5 C 45 C 41 F 113 F at 85 relative humidity Storage Temperature 5 C 60 C 23 F 140 F at 85 relative humidity Factory Default Setting Country Setting US Voltage 120 Units Imperial LB F Currency cents Power Units KW Energy Units KWH GHG Units LB hr Accumulative GHG Units Ton Temperature Units F GHG Conversion 1 27LB CO2 1KW hr Clock 12 hr Date mmdd Tariff ...

Страница 10: ... reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or a...

Страница 11: ... sent with the proof of purchase and product to the following address Customer Services Curo Energy 10322 Pine Forest Road Houston TX 77042 NOTE A record of the Return Reference Number should be kept and used in all correspondence relating to the return No returns will be accepted without a Returns Reference Number being allocated All returns must be by recorded delivery Product Name Product Model...