Operation
UNIT 2
Fiber Length Measurement
1 - On one end of the fiber cable, loop back two of the
fibers with one of the patch cords.
2 - On the other end of the fiber cable, connect one patch
cord to each of the fibers being used for the test.
Connect the other end of the patch cords to the
receiver and transmitter ports on the BOLT. It does not
matter which patch cord connects to which fiber.
3 - Power on the BOLT into length test mode by flipping
the switch to TEST. In a few seconds, the display will
show the length of the fiber in kilometers. In the
example at right, the link is 1.250 kilometers.
NOTE: If the green indicator LED does not light up, this
means that the battery power insufficient for a valid test.
The battery must be replaced before continuing.
Fiber Identification
1 - Connect the BOLT to the fiber you are testing via a
patch cord as shown at right.
2 - Power on the BOLT into fiber identification mode by
flipping the switch to TEST. This mode emits a flashing
beam of invisible light into the fiber.
3 - Identify the fiber by clamping a fiber identifier to the
fibers until you locate the fiber being tested. Many
identifiers produce an audible tone.
Fiber Length Measurement
1.250
Patch
Cords
Fiber
Link
2-1
- - - -
Patch
Cord
Fiber
Link
Fiber Identification
Beware of invisible
optical radiation!
Add Clip On
Identifier