background image

Table of Contents

Cover - Important Safety Information

1

Important Safety Information and

Minimum Clearances to Combustibles

2

Pre-Installation & Preparation Guidelines

3

Important Safety Information

4

Installation Information

Connecting the Gas to the Fire Pit

5

Propane Tank Information

6

Media Placement and Replacement Parts List

Certified Media List

7

Gem, Mirrored, and Crushed Glass Installation

8

Ceramic Rock Media Installation

9

Trouble Shooting Guide

10

Warranty Information

11

Operation Instructions

Lighting Instructions

12

Propsition 65 Public Warning

13

Conversion to a Different Gas Type

14

A.

B.

C.

D.

E.

OUTDOOR FIRE PIT - TABLE OF CONTENTS

IMPORTANT SAFETY INFORMATION

READ THESE INSTRUCTIONS FULLY BEFORE INSTALLING THIS OUTDOOR FIRE PIT.

If not installed and used correctly per these instructions,

this product can cause serious injury, death, and or property damage and may void the warranty.

CAUTION

:  FIXED PIPING GAS SUPPLY INSTALLATION, AND REPAIRS MUST BE DONE BY

A CERTIFIED PROFESSIONAL TECHNICIAN or LICENSED PLUMBER.

Be sure you understand all safety precautions and warnings contained in this manual.

If you have any questions, please contact O.W. Lee at (800) 776-9533

Figure 1

IMPROPER INSTALLATION OR USE OF YOUR OUTDOOR FIRE PIT CAN CAUSE SERIOUS INJURY,  DEATH, AND OR 
PROPERTY DAMAGE FROM FIRE, BURNS, EXPLOSIONS OR CARBON MONOXIDE POISONING.

Clearances to Combustible Construction:

Sidewalls:  60”  (1.5 m) from center of unit (Figure 1)
Ceiling:  60” (1.5 m) from top of unit to ceiling or overhang
Flooring:  0” – Can be installed on deck, slab, floor, etc.

The dimensions shown in Figure 1 are MINIMUM
CLEARANCES to maintain when you install this Outdoor Fire 
Pit.  THERE MUST BE AT LEAST 60” of clearance from the 
center of the unit  to any combustible sidewalls, ceilings, or 
material.

Page 2

CHECK STATE AND LOCAL BUILDING CODES TO DETERMINE IF THE OUTDOOR FIRE PIT IS PERMITTED IN
YOUR LOCALITY BEFORE INSTALLATION.

FOR OUTDOOR USE ONLY.  THIS UNIT MUST BE INSTALLED AT LEAST 60” FROM CENTER OF BURNER TO ANY 
COMBUSTIBLE WALLS, CEILINGS, OR MATERIAL.

WHEN SHUTTING OFF THE UNIT — BE SURE TO TURN THE CONTROL VALVE ON THE FIRE PIT TO THE FULLY OFF 
POSITION ON THE FIRE PIT and CLOSE THE VALVE ON THE PROPANE TANK or NATURAL GAS SUPPLY LINE.

WARNING:  CARBON MONOXIDE POISONING MAY LEAD TO DEATH. 

 DO NOT MODIFY THIS OUTDOOR FIRE PIT

OR ITS CONTROLS, EXCEPT AS PROVIDED FOR IN THIS MANUAL.

MINIMUM CLEARANCE TO COMBUSTIBLES

NOTE

MINIMUM OF 60” (1.5 m) CLEARANCE ABOVE THE 

OUTDOOR FIRE PIT IF INSTALLED UNDER CEILING OR 

OVERHANG 

60” (1.5 m)

CLEARANCE

FROM CENTER

TO ANY

COMBUSTIBLE

CONSTRUCTION

60” (1.5 m)

CLEARANCE

FROM CENTER

TO ANY 

COMBUSTIBLE

CONSTRUCTION

Содержание 5152-2545O

Страница 1: ...ng codes to the National Fuel Gas Code ANSI Z223 1 NFPA 54 International Fuel Gas Code Natural Gas and Propane Installation Code CSA B149 1 or Propane Storage and Handling Code B149 2 as applicable READ THESE INSTRUCTIONS FULLY BEFORE INSTALLING THIS OUTDOOR FIRE PIT If the information in this manual is not followed exactly a fire or explosion may result causing personal injury death or property d...

Страница 2: ...R USE OF YOUR OUTDOOR FIRE PIT CAN CAUSE SERIOUS INJURY DEATH AND OR PROPERTY DAMAGE FROM FIRE BURNS EXPLOSIONS OR CARBON MONOXIDE POISONING Clearances to Combustible Construction Sidewalls 60 1 5 m from center of unit Figure 1 Ceiling 60 1 5 m from top of unit to ceiling or overhang Flooring 0 Can be installed on deck slab floor etc The dimensions shown in Figure 1 are MINIMUM CLEARANCES to maint...

Страница 3: ...intend to use may not be the same that your fire pit was setup for or is stated on your outdoor rating plate THIS FIRE PIT IS CONSTRUCTED FOR USE WITH PROPANE GAS If the gas supply is different or you wish to change to Natural Gas you MUST have the Fire Pit Converted directions to convert can be found on page 14 to the gas type you intend to use Any gas type conversion should be performed by a qua...

Страница 4: ...or near the O DO NOT use this appliance if any part of it has been under water Call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control part which has been under water before using J WARNING DO NOT BURN SOLID FUEL IN THIS FIRE PIT K WARNING Improper installation adjustment alteration service or maintenance can cause injury death...

Страница 5: ...y building garage or other enclosed area 3 Make sure the appliance is NOT in use and turn OFF the gas at the supply LP Gas Cylinder Valve The LP Gas Cylinder must be disconnected when the appliance is not in use 20 Pound Horizontal Tank CONNECTING AN LP GAS CYLINDER PROPANE TANK TO THE FIRE PIT 6 The LP Gas Cylinder must be standing on the designed bottom base of the cylinder for proper vapor with...

Страница 6: ...d in an upright position with cylinder valve turned off Page 06 Consult manufacturer s instructions concerning the cylinder connection provided with your Do not check for gas leaks with a match or an open flame Apply soapy water to areas marked X Open cylinder valve If bubble appears close valve and have LP gas service person make needed repairs Also check appliance valves and connections to make ...

Страница 7: ...pit are porous and when heated up to normal operating temperature can cause trapped gasses or moisture to expand and cause a pop and launch outside of the fire pit which could cause injury or property damage Allow lava granules to completely dry after getting wet rained on or hosed off before lighting and using the fire pit REPLACEMENT PARTS AND MEDIA ARE AVAILABLE THROUGH YOUR LOCAL DEALER Page 7...

Страница 8: ...damage Allow lava granules to completely dry after getting wet rained on or hosed off before lighting and using the fire pit Page 8 GEM MIRRORED AND CRUSHED GLASS MEDIA PLACEMENT GEM MIRRORED AND CRUSHED GLASS MEDIA PLACEMENT Carefully inspect the carton for shipping damage If any parts are missing or damaged call your dealer Do not attempt to install the appliance unless all parts are in good con...

Страница 9: ... PROPER OPERATION OF YOUR FIRE PIT IF YOU NEED TO REPOSITION ANY MATERIAL TO MAINTAIN THE PROPER LAYOUT USE HEAT RESISTANT GLOVES OR ALLOW MATERIAL ADEQUATE TIME TO COOL BEFORE HANDLING CAUTION Lava granules used in a fire pit are porous and when heated up to normal operating temperature can cause trapped gasses or moisture to expand and cause a pop and launch outside of the fire pit which could c...

Страница 10: ...ifferent Gas Type on how to access the venturi the orifice Insert a small wire in the venturi orifice holes to clear passage free of spider webs or other debris Make sure to put everything back correctly when finished for proper fire pit operation and safety This is a common problem when the fire pit has not been used for an extended period of time Low or Excessive Flame Using Natural Gas The wate...

Страница 11: ...structions Fire Pit Component Parts O W Lee extends a two 2 year limited warranty on all burner components under normal use and proper maintenance OW Lee will at factory option repair or replace any outdoor fire pit burner found to be defective during this warranty period Regular maintenance must be exercised as set forth in the owner s manual For more information go to www owlee com Items Not Cov...

Страница 12: ...to turn the gas valve key never use tools If the valve does not turn DO NOT force it or try to repair it Call a qualified professional service technician for assistance on the repair Forcing or attempting to repair the knob may result in fire or explosion serious injury death or property damage DO NOT use this appliance if any part has been under water Immediately call a qualified service technici...

Страница 13: ...a for various uses Propane itself is not a listed Proposition 65 chemical The combustion of propane in appliances such as stoves or heating systems and vehicles using propane creates harmful chemicals These chemicals include carbon monoxide benzene formaldehyde and acetaldehyde All chemicals known to the State to cause cancer and or birth defects The Company encourages all of its customers to use ...

Страница 14: ...CTRICAL SOURCES APPLIANCES ARE SHUT OFF 2 Carefully detach the flex line connector hose attached to the orifice holder Figure 1 and unscrew the orifice holder from the burner pipe Figures 1 and 2 This Conversion should only be performed by a Qualified Service Technician or Licensed Plumber Page 14 FIGURE 2 After The Unit Is Converted it Must Be Tested to Verify the Inlet and Manifold pressures are...

Страница 15: ...NOXYDE DE CARBONE Cet appareil peut produire du monoxyde de carbone qui n a pas d odeur Son utilisation dans un espace clos peut vous tuer N utilisez jamais cet appareil dans un espace clos tel qu une caravane une tente une voiture ou à la maison 4 Après avoir quitté les lieux appelez votre fournisseur de gaz ou le service d incendie DANGER Cet appareil à gaz est conçu comme un appareil surveillé ...

Страница 16: ...TION INCORRECTE OU UTILISÉE DE VOTRE PUITS D INCENDIE EXTÉRIEUR PEUT CAUSER DES BLESSURES GRAVES LA MORT OU DES DOMMAGES À LA PROPRIÉTÉ EN CAS D INCENDIE DE BRÛLURES D EXPLOSIONS OU D EMPOISONNEMENT AU MONOXYDE DE CARBONE Parois 60 1 5 m du centre de l unité Figure 1 Plafond 60 1 5 m de haut de l unité au plafond ou faux Revêtement de sol 0 Peut être installé sur le pont la dalle le plancher etc L...

Страница 17: ...z doit être dimensionné de sorte à fournir la pression minimale d admission au débit maximum BTU hr Une perte excessive de pression se produira si le tuyau est trop petit ou trop long G Casual Fireside foyers sont adaptés pour l installation à partir de 0 4500 m sans modification H Si le foyer extérieur est raccordé au gaz naturel sa valve principale de gaz doit être déconnectée du système de tuya...

Страница 18: ...on et les réparations doivent être effectuées par un technicien qualifié L appareil doit être inspecté avant utilisation et au moins une fois par an par un technicien qualifié Un nettoyage plus fréquent peut être nécessaire si nécessaire Il est impératif que le compartiment de commande les brûleurs et les passages d air de circulation de l appareil restent propres Le brûleur doit être remplacé ava...

Страница 19: ...de gaz GPL doit reposer sur la base inférieure de la bouteille conçue pour permettre un retrait approprié de la vapeur 1 2 La ou les bouteilles de gaz LP à utiliser doivent être construites et marquées conformément aux directives du département américain de la Transport D O T Spécifications des bouteilles de gaz LP ou norme sur les bouteilles sphères et tubes pour le transport des marchandises dan...

Страница 20: ...ez vous que la date de requalification des bouteilles est vérifiée Assurez vous que l évent du régulateur ne pointe pas vers le haut Ne pas utiliser stocker ou transporter la bouteille dans un endroit où elle serait exposée à des températures élevées La soupape de décharge peut s ouvrir et permettre à une grande quantité de gaz inflammable de s échapper Lors du transport garder le cylindre bien en...

Страница 21: ...ées à la température de fonctionnement normale peut provoquer une expansion des gaz piégés ou de l humidité et provoquer un éclatement et un lancement à pourrait causer des blessures ou des dommages matériels Laissez les granules de lave sécher complètement après avoir été mouillées avant de les allumer et en utilisant le foyer POSE DES GRANULES DE LAVE ET DES CRISTAUX DE VERRE Figure 1 LISTE DES ...

Страница 22: ...EN VERRE GEM MIROIR ET BROYÉ Versez le verre gem média en verre pilé dans le Foyer extérieur pour que le brûleur soit complètement recouvert Voir les figures 1 et 2 Figure 1 Versez le premier sac de verre dans le support du brûleur Figure 2 Versez les sacs supplémentaires de média sur le support du brûleur Étalez le support uniformément en couvrant le brûleur Figure 3 Verser les sacs supplémentair...

Страница 23: ... DEVEZ MAINTENIR LA DISPOSITION COMME INDIQUÉE POUR ASSURER LE BON FONCTIONNEMENT DE VOTRE PUITS SI VOUS DEVEZ REPOSER TOUT MATÉRIAU POUR MAINTENIR LA DISPOSITION APPROPRIÉE UTILISEZ LA CHALEUR GANTS RÉSISTANTS OU PERMETTRE AU MATÉRIEL UN TEMPS APPROPRIÉ DE SE REFROIDIR AVANT MANIPULATION ATTENTION les granules de lave utilisées dans un foyer sont poreuses et chauffées à la température de fonction...

Страница 24: ... petit fil dans le venturi et orifices des trous pour dégager le passage libre des toiles d araignées ou d autres débris Assurez vous de tout remettre correctement lorsque vous avez terminé pour le fonctionnement du foyer adéquat et la sécurité Ceci est un problème commun lorsque le foyer n a pas été utilisé pendant une longue période de temps Flamme faible ou excessive Utilisation de gaz naturel ...

Страница 25: ... Parties Pit Fire O W Lee offre une garantie limitée de deux 2 ans sur tous les composants du brûleur en utilisation normale et appropriée entretien OW Lee sera à l usine de réparer ou de remplacer tout brûleur extérieur foyer trouvé défectueux pendant cette période de garantie Un entretien régulier doit être exercé selon dans le manuel du propriétaire Pour plus d informations consultez www owlee ...

Страница 26: ...Si l odeur persiste éloignez vous de l appareil et appelez immédiatement votre fournisseur de gaz ou le service des incendies Utilisez uniquement votre main pour enfoncer et tourner le bouton de contrôle du gaz ne jamais utiliser d outils Si le bouton ne s enfonce pas ou ne tourne pas à la main NE PAS le forcer ou essayer de le réparer Appelez un technicien de service qualifié et professionnel pou...

Страница 27: ... chimique répertorié de la Proposition 65 La combustion de propane dans des appareils tels que des poêles ou des systèmes de chauffage et des véhicules utilisant du propane crée des produits chimiques nocifs Ces produits chimiques comprennent le monoxyde de carbone le benzène le formaldéhyde et l acétaldéhyde Tous les produits chimiques reconnus par l État comme pouvant causer le cancer et ou des ...

Страница 28: ...ne solution de savon liquide sur toutes les connexions avant de mettre l unité en marche 5 IL EST NÉCESSAIRE DE POSER L ÉTIQUETTE OU LA PLAQUE SIGNALÉTIQUE INCLUSE DANS LE KIT DE CONVERSION AFIN D INDIQUER CLAIREMENT LA CONVERSION FAITE SUR PLACE Casual Fireside foyers sont adaptés pour l installation à partir de 0 4500 m sans modification Suivez les étapes 1 à 5 ci dessus LA CONVERSION DOIT ÊTRE ...

Отзывы: