GAS PRESSURE REQUIREMENTS:  FOR NATURAL GAS:

The minimum inlet gas supply pressure for purposes of input adjustment is

 3.5 inches

 (127 mm) water column and maximum 

inlet gas supply pressure is 

10.5 inches

 (266.7 mm) water column.

FOR PROPANE: 

 The minimum inlet gas supply pressure for purposes of input adjustment is 

8 inches

(203 mm) water column and the maximum inlet gas supply pressure is 

13 inches

 (330 mm) water column.

MANIFOLD PRESSURE REQUIREMENT

:   Liquid Propane 9.5 (241.3mm)  / Natural Gas 2.5 (63.5mm) of pressure.

DO NOT INSTALL THIS UNIT IF MINIMUM PRESSURE IS NOT AVAILABLE OR IF MAXIMUM PRESSURE IS EXCEEDED.

Page 3

SAFETY NOTE:  

Fire pits connected to a fixed piped gas line, require a second gas shut off valve.  The valve must be kept in 

the off position when the fire pit is not in use.  The secondary valve shuts off the gas supply to the fire pit and allows for 
maintenance and repair.

O.

D.

E.

Casual Fireside Fire Pits are suitable for installation from 0 - 4,500 ft. elevation without modification.

M.

F. Fixed Gas piping system must be sized to provide minimum inlet pressure at the maximum flow rate (BTU/hr).  Undue 

pressure loss will occur if the pipe is too small or the run is too long.

A. Before installing the Outdoor Fire Pit, check “Minimum Clearance to Combustibles” on page 2.

MINIMUM CLEARANCES

 must be maintained when you install this Outdoor Fire Pit.  

THERE  MUST

BE AT LEAST 60”

 (1.5 m) from the center of the burner to any combustible sidewall, ceiling, or material.  

The Outdoor Fire Pit is for outdoor use only.  DO NOT install or use this appliance inside a building,
garage, or any other enclosed area or structure including recreational vehicles, boats & sheds.  

This unit must be

installed in such a manner that proper air ventilation is maintained without obstruction at all times, and during all 
weather conditions. 

B.

C.

CHECK GAS TYPE

 (Natural Gas or Propane):  The gas supply you intend to use may not be the same that your fire pit was 

setup for or is stated on your outdoor rating plate.  

THIS FIRE PIT IS CONSTRUCTED FOR USE WITH PROPANE

 

GAS

.  If 

the gas supply is different, 

or you wish to change to Natural Gas, you MUST have the Fire Pit Converted (directions to 

convert can be found on page 14) to the gas type you intend to use.  Any gas type conversion should be performed 
by a qualified, professional technician or licensed plumber

.  If you are unsure, contact your dealer for assistance.

INSTALLER NOTE:  This unit should be installed so that it can be removed at a later date for service.

K.

Propane Regulator Hose 

(when used):   The propane regulator hose is located inside the fire pit door panel.  When 

installed, make sure the hose is secured inside the unit and 

DOES NOT TOUCH THE BURNER PAN.

L.

Propane Regulator Hose:

  Always inspect the condition of the propane regulator hose before each operation.  Any signs of 

excessive abrasion the hose MUST BE REPLACED.  Contact your local dealer for replacement part #COM0589

I.

If the Outdoor Fire Pit is connected to a fixed piping gas supply line, the supply line is required to have an on/off gas valve 
installed before the fire pit must be closed during any pressure testing of the system at test pressures equal to or less than ½ 
psi (3.5kPa).

N.

IMPORTANT SAFETY INFORMATION 

Pre-Installation & Preparation Guidelines

If the Outdoor Fire Pit is connected to a fixed piping gas supply line, the supply line is required to have an on/off gas valve 
installed before the fire pit and it must be closed during any pressure testing of the system at test pressures in excess of ½ 
psi (3.5kPa).  

G.

H.

DO NOT USE IF GAS PRESSURE IS LOWER THAN THE MINIMUM REQUIREMENT OR EXCEEDS THE MAXIMUM.

J.

Note:  The Use Of A Third Party Fire Pit Top, Media and or Components Will Void the LABTEST Certification
and O.W Lee Warranty. 

GAS SUPPLY PLUMBING REQUIREMENTS 

Apply only joint compounds that are resistant to all gasses on all male pipe fittings.  Make sure to tighten every joint securely.  

DO NOT use pipe joint compound to connect flare fittings

.

Содержание 5152-2545O

Страница 1: ...ng codes to the National Fuel Gas Code ANSI Z223 1 NFPA 54 International Fuel Gas Code Natural Gas and Propane Installation Code CSA B149 1 or Propane Storage and Handling Code B149 2 as applicable READ THESE INSTRUCTIONS FULLY BEFORE INSTALLING THIS OUTDOOR FIRE PIT If the information in this manual is not followed exactly a fire or explosion may result causing personal injury death or property d...

Страница 2: ...R USE OF YOUR OUTDOOR FIRE PIT CAN CAUSE SERIOUS INJURY DEATH AND OR PROPERTY DAMAGE FROM FIRE BURNS EXPLOSIONS OR CARBON MONOXIDE POISONING Clearances to Combustible Construction Sidewalls 60 1 5 m from center of unit Figure 1 Ceiling 60 1 5 m from top of unit to ceiling or overhang Flooring 0 Can be installed on deck slab floor etc The dimensions shown in Figure 1 are MINIMUM CLEARANCES to maint...

Страница 3: ...intend to use may not be the same that your fire pit was setup for or is stated on your outdoor rating plate THIS FIRE PIT IS CONSTRUCTED FOR USE WITH PROPANE GAS If the gas supply is different or you wish to change to Natural Gas you MUST have the Fire Pit Converted directions to convert can be found on page 14 to the gas type you intend to use Any gas type conversion should be performed by a qua...

Страница 4: ...or near the O DO NOT use this appliance if any part of it has been under water Call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control part which has been under water before using J WARNING DO NOT BURN SOLID FUEL IN THIS FIRE PIT K WARNING Improper installation adjustment alteration service or maintenance can cause injury death...

Страница 5: ...y building garage or other enclosed area 3 Make sure the appliance is NOT in use and turn OFF the gas at the supply LP Gas Cylinder Valve The LP Gas Cylinder must be disconnected when the appliance is not in use 20 Pound Horizontal Tank CONNECTING AN LP GAS CYLINDER PROPANE TANK TO THE FIRE PIT 6 The LP Gas Cylinder must be standing on the designed bottom base of the cylinder for proper vapor with...

Страница 6: ...d in an upright position with cylinder valve turned off Page 06 Consult manufacturer s instructions concerning the cylinder connection provided with your Do not check for gas leaks with a match or an open flame Apply soapy water to areas marked X Open cylinder valve If bubble appears close valve and have LP gas service person make needed repairs Also check appliance valves and connections to make ...

Страница 7: ...pit are porous and when heated up to normal operating temperature can cause trapped gasses or moisture to expand and cause a pop and launch outside of the fire pit which could cause injury or property damage Allow lava granules to completely dry after getting wet rained on or hosed off before lighting and using the fire pit REPLACEMENT PARTS AND MEDIA ARE AVAILABLE THROUGH YOUR LOCAL DEALER Page 7...

Страница 8: ...damage Allow lava granules to completely dry after getting wet rained on or hosed off before lighting and using the fire pit Page 8 GEM MIRRORED AND CRUSHED GLASS MEDIA PLACEMENT GEM MIRRORED AND CRUSHED GLASS MEDIA PLACEMENT Carefully inspect the carton for shipping damage If any parts are missing or damaged call your dealer Do not attempt to install the appliance unless all parts are in good con...

Страница 9: ... PROPER OPERATION OF YOUR FIRE PIT IF YOU NEED TO REPOSITION ANY MATERIAL TO MAINTAIN THE PROPER LAYOUT USE HEAT RESISTANT GLOVES OR ALLOW MATERIAL ADEQUATE TIME TO COOL BEFORE HANDLING CAUTION Lava granules used in a fire pit are porous and when heated up to normal operating temperature can cause trapped gasses or moisture to expand and cause a pop and launch outside of the fire pit which could c...

Страница 10: ...ifferent Gas Type on how to access the venturi the orifice Insert a small wire in the venturi orifice holes to clear passage free of spider webs or other debris Make sure to put everything back correctly when finished for proper fire pit operation and safety This is a common problem when the fire pit has not been used for an extended period of time Low or Excessive Flame Using Natural Gas The wate...

Страница 11: ...structions Fire Pit Component Parts O W Lee extends a two 2 year limited warranty on all burner components under normal use and proper maintenance OW Lee will at factory option repair or replace any outdoor fire pit burner found to be defective during this warranty period Regular maintenance must be exercised as set forth in the owner s manual For more information go to www owlee com Items Not Cov...

Страница 12: ...to turn the gas valve key never use tools If the valve does not turn DO NOT force it or try to repair it Call a qualified professional service technician for assistance on the repair Forcing or attempting to repair the knob may result in fire or explosion serious injury death or property damage DO NOT use this appliance if any part has been under water Immediately call a qualified service technici...

Страница 13: ...a for various uses Propane itself is not a listed Proposition 65 chemical The combustion of propane in appliances such as stoves or heating systems and vehicles using propane creates harmful chemicals These chemicals include carbon monoxide benzene formaldehyde and acetaldehyde All chemicals known to the State to cause cancer and or birth defects The Company encourages all of its customers to use ...

Страница 14: ...CTRICAL SOURCES APPLIANCES ARE SHUT OFF 2 Carefully detach the flex line connector hose attached to the orifice holder Figure 1 and unscrew the orifice holder from the burner pipe Figures 1 and 2 This Conversion should only be performed by a Qualified Service Technician or Licensed Plumber Page 14 FIGURE 2 After The Unit Is Converted it Must Be Tested to Verify the Inlet and Manifold pressures are...

Страница 15: ...NOXYDE DE CARBONE Cet appareil peut produire du monoxyde de carbone qui n a pas d odeur Son utilisation dans un espace clos peut vous tuer N utilisez jamais cet appareil dans un espace clos tel qu une caravane une tente une voiture ou à la maison 4 Après avoir quitté les lieux appelez votre fournisseur de gaz ou le service d incendie DANGER Cet appareil à gaz est conçu comme un appareil surveillé ...

Страница 16: ...TION INCORRECTE OU UTILISÉE DE VOTRE PUITS D INCENDIE EXTÉRIEUR PEUT CAUSER DES BLESSURES GRAVES LA MORT OU DES DOMMAGES À LA PROPRIÉTÉ EN CAS D INCENDIE DE BRÛLURES D EXPLOSIONS OU D EMPOISONNEMENT AU MONOXYDE DE CARBONE Parois 60 1 5 m du centre de l unité Figure 1 Plafond 60 1 5 m de haut de l unité au plafond ou faux Revêtement de sol 0 Peut être installé sur le pont la dalle le plancher etc L...

Страница 17: ...z doit être dimensionné de sorte à fournir la pression minimale d admission au débit maximum BTU hr Une perte excessive de pression se produira si le tuyau est trop petit ou trop long G Casual Fireside foyers sont adaptés pour l installation à partir de 0 4500 m sans modification H Si le foyer extérieur est raccordé au gaz naturel sa valve principale de gaz doit être déconnectée du système de tuya...

Страница 18: ...on et les réparations doivent être effectuées par un technicien qualifié L appareil doit être inspecté avant utilisation et au moins une fois par an par un technicien qualifié Un nettoyage plus fréquent peut être nécessaire si nécessaire Il est impératif que le compartiment de commande les brûleurs et les passages d air de circulation de l appareil restent propres Le brûleur doit être remplacé ava...

Страница 19: ...de gaz GPL doit reposer sur la base inférieure de la bouteille conçue pour permettre un retrait approprié de la vapeur 1 2 La ou les bouteilles de gaz LP à utiliser doivent être construites et marquées conformément aux directives du département américain de la Transport D O T Spécifications des bouteilles de gaz LP ou norme sur les bouteilles sphères et tubes pour le transport des marchandises dan...

Страница 20: ...ez vous que la date de requalification des bouteilles est vérifiée Assurez vous que l évent du régulateur ne pointe pas vers le haut Ne pas utiliser stocker ou transporter la bouteille dans un endroit où elle serait exposée à des températures élevées La soupape de décharge peut s ouvrir et permettre à une grande quantité de gaz inflammable de s échapper Lors du transport garder le cylindre bien en...

Страница 21: ...ées à la température de fonctionnement normale peut provoquer une expansion des gaz piégés ou de l humidité et provoquer un éclatement et un lancement à pourrait causer des blessures ou des dommages matériels Laissez les granules de lave sécher complètement après avoir été mouillées avant de les allumer et en utilisant le foyer POSE DES GRANULES DE LAVE ET DES CRISTAUX DE VERRE Figure 1 LISTE DES ...

Страница 22: ...EN VERRE GEM MIROIR ET BROYÉ Versez le verre gem média en verre pilé dans le Foyer extérieur pour que le brûleur soit complètement recouvert Voir les figures 1 et 2 Figure 1 Versez le premier sac de verre dans le support du brûleur Figure 2 Versez les sacs supplémentaires de média sur le support du brûleur Étalez le support uniformément en couvrant le brûleur Figure 3 Verser les sacs supplémentair...

Страница 23: ... DEVEZ MAINTENIR LA DISPOSITION COMME INDIQUÉE POUR ASSURER LE BON FONCTIONNEMENT DE VOTRE PUITS SI VOUS DEVEZ REPOSER TOUT MATÉRIAU POUR MAINTENIR LA DISPOSITION APPROPRIÉE UTILISEZ LA CHALEUR GANTS RÉSISTANTS OU PERMETTRE AU MATÉRIEL UN TEMPS APPROPRIÉ DE SE REFROIDIR AVANT MANIPULATION ATTENTION les granules de lave utilisées dans un foyer sont poreuses et chauffées à la température de fonction...

Страница 24: ... petit fil dans le venturi et orifices des trous pour dégager le passage libre des toiles d araignées ou d autres débris Assurez vous de tout remettre correctement lorsque vous avez terminé pour le fonctionnement du foyer adéquat et la sécurité Ceci est un problème commun lorsque le foyer n a pas été utilisé pendant une longue période de temps Flamme faible ou excessive Utilisation de gaz naturel ...

Страница 25: ... Parties Pit Fire O W Lee offre une garantie limitée de deux 2 ans sur tous les composants du brûleur en utilisation normale et appropriée entretien OW Lee sera à l usine de réparer ou de remplacer tout brûleur extérieur foyer trouvé défectueux pendant cette période de garantie Un entretien régulier doit être exercé selon dans le manuel du propriétaire Pour plus d informations consultez www owlee ...

Страница 26: ...Si l odeur persiste éloignez vous de l appareil et appelez immédiatement votre fournisseur de gaz ou le service des incendies Utilisez uniquement votre main pour enfoncer et tourner le bouton de contrôle du gaz ne jamais utiliser d outils Si le bouton ne s enfonce pas ou ne tourne pas à la main NE PAS le forcer ou essayer de le réparer Appelez un technicien de service qualifié et professionnel pou...

Страница 27: ... chimique répertorié de la Proposition 65 La combustion de propane dans des appareils tels que des poêles ou des systèmes de chauffage et des véhicules utilisant du propane crée des produits chimiques nocifs Ces produits chimiques comprennent le monoxyde de carbone le benzène le formaldéhyde et l acétaldéhyde Tous les produits chimiques reconnus par l État comme pouvant causer le cancer et ou des ...

Страница 28: ...ne solution de savon liquide sur toutes les connexions avant de mettre l unité en marche 5 IL EST NÉCESSAIRE DE POSER L ÉTIQUETTE OU LA PLAQUE SIGNALÉTIQUE INCLUSE DANS LE KIT DE CONVERSION AFIN D INDIQUER CLAIREMENT LA CONVERSION FAITE SUR PLACE Casual Fireside foyers sont adaptés pour l installation à partir de 0 4500 m sans modification Suivez les étapes 1 à 5 ci dessus LA CONVERSION DOIT ÊTRE ...

Отзывы: