background image

5

For Help, call 1-800-784-5028 or visit www.overheaddoor.com

P

RE

-I

NSTALLATION

C

HECKLIST

This Opener includes parts and supplies needed to install in most garages and 
connect to most garage doors. There are many variations of garages and garage 
doors. A few additional parts and supplies may be needed to install Opener into 
your garage and connect to your garage door. While checking items listed 
below, note any additional items you will need.

Tools used in this section:

• 12'+ Tape Measure      • Pencil      • Ladder     • Level

Check following items before assembling Opener:

C

HECK

D

OOR

C

ONDITION AND

T

HICKNESS

Check condition of vertical stile in center of door, (Figure 2) and its connection
to door’s top and bottom beams.

A

If door frame is nailed together and not a solid connection, door frame 
must be braced or reinforced before installing Opener.

B

If door is “lightweight” (made with frame and skin - not solid), door 
(including door frame) must be braced or reinforced before         
installing Opener.

C

A door opener reinforcement bracket may also be needed to connect 
garage door to Opener's Door Bracket. This Opener is designed for 
installation on a properly braced sectional door or solidly braced
one-piece door.

D

Contact your Overhead Door Distributor or dealer of your garage 
door for any necessary bracing and a door opener reinforcement 
bracket (if needed) before proceeding.

E

If you have a wooden door, measure door’s thickness. (1/4" x 2") Lag  
Screws are included for installing Door Bracket onto door. If your door 
is less than 2” thick, brace door or use shorter Door Bracket Lag 
Screws (1/4" x 1-1/4" – not included)

Check Step 1:

C

HECK

G

ARAGE

D

OOR

A

LIGNMENT

, O

PERATION

,

AND

B

ALANCE

A

Raise door, check alignment and see if it moves freely (Figure 1). If door 
appears out of alignment, binds, or does not move smoothly, contact an 
Overhead Door Distributor or dealer of your garage door for repairs 
and adjustments to door mechanism.

B

Raise door to 3' – 4' above ground and carefully let go. Door should stay 
stationary. Slight movement is acceptable. More than slight movement 
means door is out of balance. Contact an Overhead Door Distributor
or dealer of your garage door 
for repairs and adjustments 
to door mechanism.

C

Check door type. Make 
a note of whether it is a
sectional or a one-piece                                                                                
door (Figure 2).

Check Step 2:

WARNING:

If your door sticks, binds, or is out of 
balance, have it adjusted by an Overhead
Door Distributor. Door springs, cables,
pulleys, brackets and associated hardware
are under extreme tension and can cause
serious injury or death.

NOTE

The Powermax Opener is equipped with 
an Automatic Garage Door Balance
Detection System. See Troubleshooting
Guide on page 16.

KEEP FEET CLEAR OF DOOR

3' - 4'

Sectional Door

3' - 4'

One-Piece Door

Figure 1

Checking door balance

Figure 2

Note Door Type

Torsion Springs

Extension Springs

Center

Stile

Center Stile

Header Area

Содержание PowewrMax XL 4060

Страница 1: ...N C E Having Difficulty Need Help Please call us 1 800 784 5028 www overheaddoor com Please have Model information ready when calling Warranty Information 2 Your Documentation Page 3 Safety Informati...

Страница 2: ...r representative for assistance in diagnosing the problem and arranging to supply you with the required parts for do it yourself repairs Trained service representatives are available Monday Friday 8 0...

Страница 3: ...tenance Brochure DASMA Entrapment Warning Label To be Adhered in close proximity to wall control Assembly and Installation Poster This poster is intended to give a convenient lay flat media to be used...

Страница 4: ...is activated and auto matically turns off 4 5 minutes later Manual Emergency Release Allows the garage door to be opened or closed manually for emergencies or maintenance IMPORTANT INSTALLATION INSTR...

Страница 5: ...nt bracket if needed before proceeding E If you have a wooden door measure door s thickness 1 4 x 2 Lag Screws are included for installing Door Bracket onto door If your door is less than 2 thick brac...

Страница 6: ...to H Mark a point on center line Bottom of Header Bracket will be installed here For one piece doors add 6 to H Mark this point on center line Bottom of Header Bracket will be installed here C Check...

Страница 7: ...box must be installed Contact a licensed electrician for installation If building codes require permanent wiring Power Head must be partially disassembled to install appropriate wiring in place of Pow...

Страница 8: ...have a separate entry door it is highly recommended to install a Emergency Release Kit GER 2 Emergency Release Kit lets you open garage door from outside if there is a power failure Please see Accesso...

Страница 9: ...roubleshooting on pg 16 Tighten Limit Switch Set Screw Do not over tighten strip Limit Switch Set Screw C Adjust Open Limit Switch Press Wall Console to open garage door If door does not open complete...

Страница 10: ...en garage door using Wall Console B Lay a 2 x 4 board flat in center of doorway C Close door using Wall Console D Check that door stops and reverses within 2 seconds after it contacts board If door do...

Страница 11: ...Light blinks approximately 4 times per second programming has stopped If programming has stopped repeat the above steps Each Button on a 2 or 3 Button Remote Control is for a different Opener You can...

Страница 12: ...wded airwaves may intermittently interfere with GDO s remote control system The dual frequency feature greatly reduces the possibility of unwanted interference The receiver in the GDO s powerhead can...

Страница 13: ...4 5028 WARNING Do not operate door automatically or manually if springs are broken Contact an Overhead Door Distributor for service or call Customer Service at 1 800 784 5028 WARNING If the door fails...

Страница 14: ...14 For Help call 1 800 784 5028 or visit www overheaddoor com NOTES...

Страница 15: ...ner s Manual An improperly balanced door increases the risk of severe injury or death Have an Overhead Door Distributor make repairs to cables spring assemblies and other hardware 8 SAVE THESE INSTRUC...

Страница 16: ...a rate of 5 cycles per 10 minutes of rest Over cycled Contact Customer Service for further assistance 4 BLINKS Force Settings Check Force Settings NOTE Force Settings are not pre set at factory 1 See...

Страница 17: ...nly run closed Check Open Limit Switch for a short circuit and for proper wiring Check Open Force adjustment see Set LimitSwitches and Force Controls on page 9 Adjust as needed Check condition of gara...

Страница 18: ...des If present troubleshoot as detailed in Safe T Beam System Self Diagnostic Troubleshooting Chart See page 15 Noisy operation Ensure all fasteners are tightened Check that the garage door and Opener...

Страница 19: ...ssembly Brown green bag 1 21 8 32 x 1 Hex Head Screw green bag 2 22 Emergency Release Cord green bag 1 24 Emergency Release Knob green bag 1 25 Emergency Release Tag green bag 1 26 Header Bracket oran...

Страница 20: ...will not function unless Safe T Beam System is installed and Force Controls are properly set DO OR DO OR 12 22 24 31 35 33 36 34 32 8 15 16 9 11 5 2 6 7 8 18 1 14 13 21 46 33 10 56 19 53 1 46 6 8 18...

Страница 21: ...de la puerta desde el interior Bouton mural universel Actionne l ouvre porte de l int rieur du garage GPS 5 Perfect Stop Ensures perfect parking Stop Perfecto Asegura el estacionamiento perfecto Buto...

Страница 22: ......

Отзывы: