7. Changing PIN (Fig. 6-5).
• Open cover fully–LED blinks 1 time and
goes out.
• Enter PIN you want to change.
• Press “PROG”–LED blinks 1 time and goes out.
• Enter new PIN (up to 8 digits).
• Close cover.
NOTE: Door operator(s) must be programmed when
PIN has been changed (see step 3 or 9).
8. Adding more doors to keypad (Fig. 6-5).
• Open cover fully–LED blinks once and goes out.
• Enter PIN 1.
• Press “PROG”–LED blinks once and goes out.
• Press “PROG” again–LED blinks 2 times
per second.
• Press “PROG”–LED blinks 3 times per second.
• Enter number of doors (2 or 3).
• Press “PROG”–LED goes out.
• Close cover.
NOTE: Keypad can control up to 3 doors.
NOTE: Each door operator must be programmed
to accept the signal from keypad. Decide which
door operator will be door 1, door 2 and door 3.
.
9. Programming multiple door operators
(Fig. 6-5 & 6-6).
• Press Learn code button on operator.
• Enter PIN 1.
• Press “SEND.”
• Enter door number (1-3).
• Press “SEND.”
• Press “SEND” again to test system.
• Press “SEND” again to test system.
• Close cover.
Repeat step 9 for each door.
NOTE: Any key will control door within 30 seconds
after door begins to move or until cover is closed.
10. Operating keypad.
• Open cover.
• Enter PIN.
• Press “SEND.”
• For multiple doors–press door number–
Press send.
• Close cover.
FCC and IC CERTIFIED
This device complies with FCC Part 15 and RSS 210.
Operation is subject to the following two conditions: (1) This
device may not cause harmful interference, and (2) this
device must accept any interference, including interference
that may cause undesired operation of the device.
Changes or modifications not expressly approved by the
manufacturer could void the user’s authority to operate the
equipment.
During programming door operator could begin to
run, so stay away from moving door and its parts.
To keep door from moving, close door and
disconnect from operator by pulling
emergency release.
IMPORTANT
SAFETY INSTRUCTIONS
1. READ AND FOLLOW ALL INSTRUCTIONS.
2. Never let children operate or play with operator
controls. Keep remote control away
from children.
3. Always keep people and objects away from
moving door. Keep door in sight until it is
completely closed. NO ONE SHOULD CROSS
THE PATH OF THE MOVING DOOR.
4. Test operator monthly. The door MUST reverse
on contact with a 1-1/2 inch object (or a 2" x 4"
board laid flat) at the center of the doorway on
the floor. After adjusting either the force or the
limit of travel, retest the door operator. Failure
to adjust the operator properly may cause
severe injury or death.
5. If possible, use the emergency release only
when the door is closed. Use caution when
using this release with the door open. Weak or
broken springs may cause the door to fall
rapidly causing severe injury or death.
6. KEEP DOOR PROPERLY BALANCED. See
door owner’s manual. An improperly balanced
door could cause severe injury or death. Have
a qualified service person make repairs to
cables, spring assemblies, and other hardware.
7. The electrical power to the door operator
MUST BE turned off when cover is removed.
Electrical power must remain off while making
electrical connections.
8. SAVE THESE INSTRUCTIONS.
WARNING
To reduce the risk of
severe injury or death:
CAUTION
26