“OKF-MQ25”
Illustr. 6: Dimensions
OKF-MQ 25
2162
2151
8
0
1
0
5
6
1
2
1
5
Suitable measures (e.g. safety valves) have to be taken to en-
sure that the maximum operating pressures and maximum and
minimum operating temperatures are not exceeded or under-
cut.
DANGER
!
Flat-plate collector
Unit
“OKF-MQ 25”
Item no.
136 14 40
Gross surface area
m
2
2.61
Outer dimensions
mm
2151 x 1215 x 80
Aperture surface area
m
2
2.37
Collector connection
–
Ø 22 mm connecting nipple
Weight
kg
44
Absorption coefficient
%
␣
= 95
Emission coefficient
%
⑀
= 5
Transmission
%
= 91
Collector tilt angle freestanding installation
Grad
15 - 75
Collector tilt angle rooftop installation
Grad
15 - 75
Stagnation temperature according to EN 12975
°C
184
Max. permissible operating pressure
bar
10
Annual collector heat return (ITW 5 m²) kWh/m
2
475 kWh/m
2
K
Heat transfer liquid content
l
2.3
Glass cover
–
4 mm solar safety glass
Solar sensor (inner diameter)
mm
6 (plug-in sleeve)
Permissible pressure/suction
load of the collector glass
kN/m
2
3.2
Collector efficiency:
?
0
a
1
a
2
%
W/m
2
K
W/m
2
K
79.6
3.05
0.021
Angle correction factor
%
k
(50°) = 88
k
diff
= 82
Specific heat capacity
KJ/m
2
K
6.6
Absorber
–
Serpentine patterned absorber made
of aluminium heat conducting steel
sheet and copper pipe, laser welded
Fluid: Tyfocor LS
10l canister:
136 16 90 (OV item no.)
25l canister:
136 16 91 (OV item no.)
1 E
2
5
10 EURO L
0
50
100
150
200
250
300
350
400
0
5
10
15
20
25
30
35
40
Druckverlust [mbar]
EURO L4
EURO L40
EURO L40
EURO L4
Illustr. 7: Pressure losses for collectors connected in series de-
pending on the volume flow, heat transfer liquid: 40% glycol /
60% water at 40°C; pressure loss including connection hoses.
4.2 Markings
Indications on the type plate:
Solar- Keymark- labelling and registration
number
“OKF-MQ25”
Collector designation
136 14 40
Item number
4.3 Hydronic interconnection
Interconnection options:
One collector field consists of a maximum of 10 collectors instal-
led in parallel.
Pipework and pump design must be carried out object-related.
Pressure loss [mbar]
Pressure loss [l/m
2
h]
400
350
300
250
200
150
100
50
0
0
5
10
15
20
25
30
35
40
10 OKF-MQ 25
5 OKF-MQ 25
2 OKF-MQ 25
1 OKF-MQ 25
Collector dimensions [mm] and distance between the collec-
tors for the determination of the field dimensions.
2151
66
1
2
1
5
30
Provide an expansion distance of approx. 30 mm after the 6
th
collector. A longer compensator is required for this purpose
(item no.136 14 48).
Illustr. 8: Collector distances
Table 4 Field dimensions, width [mm], without outer connection nipple
1 collector
2 151
6 collectors
1)
13 236
2 collectors
4 363
7 collectors
1)
15 483
3 collectors
6 585
8 collectors
1)
17 700
4 collectors
8 802
9 collectors
1)
19 917
5 collectors
11 019
10 collectors
1)
22 134
1)
including 30 mm expansion distance (see above)
Содержание OKF-MQ25
Страница 22: ...22 1 3 4 2 Montage des n chsten Kollektors Abb 31 Montage des n chsten Kollektors...
Страница 26: ...26 Notizen...
Страница 35: ...35 Connection of basic and extension set 30 Nm 3 3 17 Nm 2 1 Illustr 14 Connection of basic and extension set...
Страница 48: ...48 1 3 4 2 Installation of next collector Abb 31 Installation of next collector...
Страница 52: ...52 Notes...
Страница 61: ...61 Liaison du set de base et d extension 30 Nm 3 3 17 Nm 2 1 Fig 14 Liaison du set de base et d extension...
Страница 74: ...74 1 3 4 2 Montage du capteur suivant Fig 31 Montage du capteur suivant...
Страница 78: ...78 Notes...
Страница 79: ...79 Notes...
Страница 80: ...80...