NB:
If the IP address is showing “000.000.000.000” then AfterBurner has been
unable to obtain an IP address via DHCP. In this case, set “DHCP enabled” to “No”
and press “Mnu+” to store the new setting. Now press ”STBY” followed by “ON” to
enable the new IP address and go back to step 4.
5 If the loader can find the AfterBurner the new firmware will automatically upgrade
which takes no more than 2 minutes.
6 If required, restore the IP addressing to DHCP on the AfterBurner and laptop
Important
F
Do not remove power whilst upgrading the unit. This is indicated by all the
front panel LEDs flashing once per second.
Set a PC to Static IP Addressing:
1. Open the network connections window via “Start” > “Control Panel” and double click
the “Network Connections” icon. Then right click “Local Area Connections” and
select Properties”
2. This opens the “Local Area Connection Properties” window. Double click the
“Internet Protocol (TCP/IP)” option. See Figure 15.
3. In the “Internet Protocol (TCP/IP) Properties” window. Click “Use the following IP
address” and enter an IP address for your PC. This must be different to any other IP
address on your network, including any AfterBuner-2s. Enter the “Subnet mask” and
“Default gateway” address as shown in Figure 15
4. Click “Use the following DNS server address” and enter the address as shown and
then click “OK”. It should now be possible to connect to the AfterBuner-2 via single
RJ45 cable.
5. To revert the PC to DHCP addressing, open then “Internet Protocol (TCP/IP)
Properties” window as above and click “Obtain an IP address automatically” and
“Obtain DNS server address automatically” followed by “OK”.
Figure 15: Set a PC to Static IP Addressing