3.9
Set Comms Options
Set Comms Options
===================
COM1: 38400,8,N,1
No ctrl RS232
Set-up of the RS232 port. The above items should not be altered unless there is a
specific reason to do so.
3.10
Set network’ menu:
The ‘Set network’ menu is used to configure AfterBurner-2 ’s Ethernet port.
Set Network
===================
DHCP enabled: Yes
IP: 192.168.000.128
DHCP enabled:
Yes/No
. (Default “Yes”) when set to ‘Yes’ AfterBurner-2 will
automatically request an IP address from a DHCP server. The
assigned IP address is shown in the “IP” setting below. When set to
“No” the IP address can be set manually.
IP:
xxx.xxx.xxx.xxx / DHCP
. When “DHCP enabled” is set to ‘No’ a static
IP address and subnet mask can be set manually entered by using
the
JMKL
buttons. The default static IP address is
‘192.168.0.128’, subnet mask ‘255.255.255.0’.
NB:
a power cycle is required for a change in IP address to take
effect.