NOTE: (1) Reaching the batch setpoint means, in the subtracting counter, the moment the total reading
has reached 0 or, in the adding counter, the total reading has reached the target batch setpoint.
(2) Batch counter display (6-digits) shows, in a subtracting counter, a negative figure below 0,
continues counting down to -99 counts and stops counting.
Above 999999 counts in the adding counter, it returns to 0 and continues counting.
(3) Cumulative total counter (8-digits) keeps adding up counts, whether adding or subtracting,
returns to 00000000 beyond 99999999 and continues counting.
RUN
OUT
ALM
COUNT
END
X
L
RUN
OUT
ALM
COUNT
END
X
L
RUN
OUT
ALM
COUNT
END
X
L
RUN
OUT
ALM
COUNT
END
X
L
Starting a continual batch process
- Shutoff valve opens.
When interrupted while shutoff valve was fully open:
Restart at full open.
- lights up.
When interrupted while shutoff valve was fully open:
Top and bottom light up.
Reaching the leading edge of final setpoint before target batch
setpoint (LW76E register equipped model only)
- Shutoff valve closes (1st step).
Final setting other than "0"
: Partially closes.
- goes out.
Final setting other than "0"
: Only top goes out.
Reaching the batch setpoint
- Shutoff valve closes (2nd step).
Final setting at "0"
: Fully closes.
Final setting other than "0"
: Fully closes.
- lights up.
Final setting at "0"
: Top and bottom go out.
Final setting other than "0"
: Top and bottom go out.
- lights up. (Normally stops counting after several
additional counts as an overshoot upon completion of a
batch process.)
Overshoot detection
- lights up.
If count still continues.
- In the subtracting counter, indicates up to – 99 counts.
OUT
OUT
OUT
ALM
A
B
END